研究目的
To design and synthesize hyper-structured molecular (HSM) thermally activated delayed fluorescent (TADF) emitters for non-doped OLEDs, aiming to overcome the problems of phase separation and efficiency roll-off in doping systems.
研究成果
The introduction of TADF units to a 3D CRA core via flexible linkage successfully synthesized HSM TADF emitters with good solubility, thermal stability, and film-forming ability. Non-doped OLEDs using CRA-PXZ-Trz(87.5)-mCP(12.5) as the emitting layer achieved an EQE of 16.7% at 100 cd/m2, demonstrating the potential of HSM design for efficient solution-processable OLEDs.
研究不足
The study focuses on the synthesis and initial characterization of HSM TADF emitters. Further optimization of device performance and stability is needed. The efficiency roll-off at higher luminance levels and the impact of the flexible linkage on device longevity are areas for future research.
1:Experimental Design and Method Selection
Designed HSM TADF emitters with TADF units and host units bound to an inactive core via flexible linkage. Used phenoxazine-triphenyltriazine (PXZ-Trz) as TADF unit, 1,3-bis(9H-carbazol-9-yl)benzene (mCP) as host unit, and calix[4]resorcinarene (CRA) as core. Synthesized via a two-step click reaction.
2:Sample Selection and Data Sources
Synthesized a series of CRA-PXZ-Trz(X)-mCP(100-X) (X=0, 12.5, 25, 50, 75, 87.5, 100) with varying molar ratios of TADF to host units.
3:List of Experimental Equipment and Materials
Used Bruker DPX-400 spectrometer for 1H NMR, Nicolet Is-10 spectrometer for FTIR, Bruker Dsltonics BIFLEX MALDI-TOF mass spectrometer for MALDI-TOF MS, Mettler-Toledo TGA/DSC for thermal analysis, Bruker AXS D8 Advance diffractometer for XRD, Dimension Fast Scan AFM for surface morphology, CHI 660E voltammetric analyzer for CV, Agilent Cary 5000 Spectrophotometer for UV-Vis, Horiba Fluorolog-3 spectrofluorometer for PL spectra.
4:Experimental Procedures and Operational Workflow
Synthesis involved alkyne-azide click reaction between alkyne-containing CRA and azide-containing functional compounds. Purified by column chromatography. OLED devices fabricated by spin-coating and evaporation techniques.
5:Data Analysis Methods
Analyzed thermal stability, photophysical properties, electrochemical behavior, and device performance. Used transient PL decay spectra to confirm TADF feature.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Bruker DPX-400 spectrometer
DPX-400
Bruker
Used for 1H NMR measurements.
-
CHI 660E voltammetric analyzer
660E
CHI
Used for cyclic voltammetry.
-
Agilent Cary 5000 Spectrophotometer
Cary 5000
Agilent
Used for UV-Vis absorption spectra.
-
Nicolet Is-10 spectrometer
Is-10
Nicolet
Used for FTIR spectra recording.
-
Bruker Dsltonics BIFLEX MALDI-TOF mass spectrometer
BIFLEX
Bruker Dsltonics
Used for MALDI-TOF MS spectra.
-
Mettler-Toledo TGA/DSC simultaneous thermal analyzer
TGA/DSC
Mettler-Toledo
Used for thermal gravimetric analysis and differential scanning calorimetry.
-
Bruker AXS D8 Advance diffractometer
D8 Advance
Bruker AXS
Used for X-ray diffraction analysis.
-
Dimension Fast Scan AFM
Fast Scan
Dimension
Used for atomic force microscopy.
-
Horiba Fluorolog-3 spectrofluorometer
Fluorolog-3
Horiba
Used for photoluminescence spectra.
-