研究目的
Investigating the characteristics of disturbance on the 9-150Khz frequency on the On-Grid solar power plants located at a gas station.
研究成果
The disturbance in the 9-150 kHz frequency range remains relatively constant with varying output power but increases during short intervals of power fluctuation. Higher disturbances are observed when power fluctuation is low.
研究不足
The study is limited to a specific frequency range (9-150 kHz) and a single location (a gas station in South Jakarta). The findings may not be generalizable to other locations or systems without further research.
1:Experimental Design and Method Selection:
The research involves measuring the disturbance characteristics of a 30 kVA rooftop photovoltaic on-grid system at a gas station. The methodology includes using a power quality analyzer and picoscope to measure disturbances in the 9-150 kHz frequency range.
2:Sample Selection and Data Sources:
The system consists of 120 modules with configurations of 10 kWp and 20 kWp. Data is collected over one week.
3:List of Experimental Equipment and Materials:
Power quality analyzer Hioki 9625 and picoscope 200 series are used for measurements.
4:Experimental Procedures and Operational Workflow:
Measurements are taken at the output side of the solar inverter. A high pass filter is connected to the picoscope for measuring the disturbance. Data is converted into the frequency domain using fast fourier transform with MATLAB.
5:Data Analysis Methods:
The relationship between power output and high frequency emission is analyzed, focusing on disturbances at 18 kHz and 54 kHz.