PATIENT DOSE IN DIGITAL RADIOGRAPHY UTILISING BMI CLASSIFICATION

DOI:10.1093/rpd/ncy194 期刊:Radiation Protection Dosimetry 出版年份:2018 更新时间:2025-09-10 09:29:36
摘要: Dose audit is important towards optimisation of patients’ radiation protection in diagnostic radiography. In this study, the effect of the body mass index (BMI) on radiation dose received by 1869 adult patients undergoing chest, abdomen, lumbar spine, kidneys and urinary bladder (KUB) and pelvis radiography in an X-ray room with a digital radiography system was investigated. Patients were categorised into three groups (normal, overweight and obese) based on the BMI values. The patients’ entrance surface air kerma (ESAK) and the effective dose (ED) were calculated based on the X-ray tube output, exposure parameters and technical data, as well as utilising appropriate conversion coefficients of the recorded kerma area product (KAP) values. The local diagnostic reference levels (LDRLs) were established at the 75th percentile of the distribution of ESAK and KAP values. Statistically, a significant increase was found in ESAK, KAP and ED values, for all examinations, both for overweight and obese patients compared to normal patients (Mann–Whitney test, p < 0.0001). Regarding the gender of the patients, a statistically significant increase was found in the dose values for male patients compared to female patients, except for the chest LAT examinations (Mann–Whitney test, p = 0.06). The percentage increase for chest PA, chest LAT, abdomen AP, lumbar spine AP, lumbar spine LAT, pelvis AP and KUB AP in overweight patients was 75%, 100%, 136%, 130%, 70%, 66% and 174% for median ESAK, 67%, 81%, 135%, 134%, 85%, 63% and 172% for median KAP, as well as 89%, 54%, 146%, 138%, 82%, 57% and 183% for median ED values, respectively. For obese patients, the corresponding increases were 200%, 186%, 459%, 345%, 203%, 150% and 785% for median ESAK, 200%, 185%, 423%, 357%, 227%, 142% and 597% for median KAP, as well as 222%, 156%, 446%, 363%, 218%, 136% and 625% for median ED. The corresponding LDRLs for overweight patients were 0.17 mGy, 1.21 mGy, 3.74 mGy, 7.70 mGy, 7.99 mGy, 4.07mGy, 5.03 mGy and 0.13 Gy cm2, 0.69 Gy cm2, 2.35 Gy cm2, 2.10 Gy cm2, 2.59 Gy cm2, 2.13 Gy cm2, 2.49 Gy cm2 in terms of ESAK and KAP values, respectively, while in the case of obese patients were 0.28 mGy, 1.82 mGy, 7.26 mGy, 15.10 mGy, 13.86 mGy, 6.89 mGy, 13.40 mGy and 0.21 Gy cm2, 1.10 Gy cm2, 4.68 Gy cm2, 4.01 Gy cm2, 4.80 Gy cm2, 3.27 Gy cm2, 6.02 Gy cm2, respectively. It can be concluded that overweight and obese patients received a significantly increased radiation dose. Careful adjustment of imaging protocols is needed for these patients to reduce patient dose, while keeping the image quality at an acceptable level. Additional studies need to be conducted for these patient groups, that could further contribute to the development of radiation protection culture in diagnostic radiography.
作者: Vasileios I. Metaxas,Gerasimos A. Messaris,Aristea N. Lekatou,Theodore G. Petsas,George S. Panayiotakis
AI智能分析
纠错
研究概述 实验方案 设备清单

To evaluate the effect of BMI on patient dose during digital radiographic examinations and to establish local diagnostic reference levels (LDRLs) for normal, overweight and obese patients.

Overweight and obese patients received significantly increased radiation doses. Careful adjustment of imaging protocols is needed for these patients to reduce dose while maintaining image quality. Establishing DRLs as a function of BMI can contribute to optimization of imaging technique and patient radiation protection.

The study was limited to data from one hospital, one radiography system, and a limited number of radiographers. The conversion coefficients used for ED calculation do not account for body size.

SCI高频之选
查看全部>
  • AQ6370D
    AQ6370D
    463

    型号:AQ6370D

    厂家:Yokogawa

    智能分析: Yokogawa AQ6370D是一款性能卓越的光谱分析仪,适用于光通信领域以及光放大器(EDFA)的测量和评估。其高波长分辨率、精准度和宽动态范围使其成为实验室和工业环境中的理想选择。虽然设备体积较大且预热时间较长,但其丰富的接口和出色的显示屏设计弥补了这些不足,整体是一款值得推荐的光谱分析仪。
    获取实验方案
  • ZEISS EVO Family

    型号:ZEISS EVO Family

    厂家:Carl Zeiss Microscopy GmbH

    智能分析: ZEISS EVO系列是一款高性能??榛璧缱酉晕⒕?,适用于材料科学、生命科学及工业质量控制等领域。其先进的技术特性包括高分辨率、广泛加速电压范围和集成EDS系统。该产品操作直观,支持多用户环境,适合科学研究和工业应用。然而,价格信息缺失以及潜在的维护成本可能是其需要注意的方面。总体而言,ZEISS EVO系列表现优秀,值得推荐给专业用户。
    获取实验方案
  • Crossbeam Family

    型号:Crossbeam Family350/550

    厂家:Carl Zeiss Microscopy GmbH

    智能分析: ZEISS Crossbeam系列是蔡司公司推出的一款高端光电分析设备,结合了场发射扫描电子显微镜(FE-SEM)和聚焦离子束(FIB)的功能,适用于材料科学、纳米技术和半导体行业等多个领域。其高分辨率成像能力和自动化样品制备功能使其成为高通量分析的理想选择。此外,该设备支持多种检测器,具备强大的多功能性,是高精度研究和工业应用的利器。然而,由于其高端定位,设备成本较高且操作需要专业技能。总体而言,该设备表现卓越,为科学研究和工业应用提供了先进的解决方案。
    获取实验方案
  • Axio Observer

    型号:Axio Observer

    厂家:Carl Zeiss Microscopy GmbH

    智能分析: Axio Observer是一款专为金相学研究设计的倒置显微镜系统,以其高效的设计和蔡司知名的光学技术为特色。它能够快速、灵活地分析大量样品,并支持自动化操作,适用于多种应用场景,包括晶粒尺寸分析、非金属夹杂物检测等。然而,其重量较大且光源寿命较短,可能对使用者提出了额外的维护和空间管理需求。总体而言,这款产品在性能和可靠性方面表现出色,特别适合专业实验室使用。
    获取实验方案
  • ZEISS LSM 990 Spectral Multiplex

    型号:ZEISS LSM 990 Spectral Multiplex

    厂家:Carl Zeiss Microscopy GmbH

    智能分析: ZEISS LSM 990 Spectral Multiplex是一款定位于高端科研机构的光谱成像系统,具有卓越的光谱分辨率和自动化功能,适用于复杂的生物、医学及材料科学实验。其高效的荧光标签分离能力和多功能自动化设计为用户提供了强大的实验支持。然而,高昂的价格和一定的学习曲线可能对中小型实验室构成挑战。总体而言,这是一款性能优越、适应性强的高端实验设备。
    获取实验方案
  • ZEISS Sigma 300 with RISE

    型号:ZEISS Sigma 300 with RISE

    厂家:Carl Zeiss Microscopy GmbH

    智能分析: ZEISS Sigma 300 with RISE是蔡司公司推出的一款高端光谱分析仪,集成了拉曼成像和扫描电子显微镜技术,能够提供高质量的化学和结构分析。其功能强大,支持多领域应用,但设备价格较高且操作学习曲线可能较陡。适用于科研机构和高端实验室,是材料科学和生命科学领域的理想选择。