The study concludes that the proposed method for calibration of the common systematic components over the entire detector plane is validated for the mid-infrared detector systems through mathematical analysis. It also confirms that the method successfully reduced the systematic components to the random ones and nearly reached the photon noise–limited performance for the temperatures of 2500, 3000, and 3500 K. The proposed method contributes to the measurement of the biosignature and habitability of terrestrial planets orbiting M-type stars.
研究不足
The study acknowledges that the systematic errors are generated by electric instability in a semiconductor device and a readout integrated circuit (ROIC), as well as the PSF movement and deformation due to the WFEs in the optical system. It also mentions that the impact of the flat-field error on the proposed method is to be mitigated by observing only the zodiacal light with both the science and background pixels and calibrating the difference between them before the science observations.
1:Experimental Design and Method Selection:
The study proposes a new method for calibration of gain variation in a detector system by developing densified pupil spectroscopy that provides multiple spectra of the star–planet system. The methodology involves averaging operations to smooth out pixel-to-pixel variations and reconstruct common time-variation components with residual pixels.
2:Sample Selection and Data Sources:
The study uses transit spectroscopy of habitable planets orbiting late-type stars, focusing on the spectrophotometric signal affected by image movement and deformation due to wavefront error and electrical variation in the detector system.
3:List of Experimental Equipment and Materials:
The study mentions the use of a densified pupil spectrograph with a mid-infrared detector system applied to a large space cryogenic telescope such as the Origins Space Telescope.
4:Experimental Procedures and Operational Workflow:
The procedure involves averaging the pixel values over all the pixels exposed by the same spectrally resolved light for the science and background pixels, as well as those over all the reference pixels, to smooth out pixel-to-pixel variations and extract the common systematic components of all of the pixels.
5:Data Analysis Methods:
The study explains the approach for analyzing experimental data, including the calibration of the common time-variation component using the reference and background pixels and the subtraction of the offset component from the science data.