研究目的
Investigating the use of fluorescence spectra to predict microcystin-LR occurrence and disinfection byproduct formation potential in lake water.
研究成果
Fluorescence spectroscopy can effectively predict microcystin-LR occurrence and DBP formation potential in lake water, offering a high-frequency monitoring tool that supplements more resource-intensive methods like LC-MS/MS.
研究不足
The study's limitations include the small size of the dataset for DBP formation potential predictions and the high correlation among fluorescence spectral inputs, which may limit the interpretability of predictive models.
1:Experimental Design and Method Selection:
The study involved collecting water samples from eight different locations around the Lake Fletcher watershed, analyzing these samples for various water quality parameters, and using fluorescence spectroscopy to predict microcystin-LR occurrence and DBP formation potential.
2:Sample Selection and Data Sources:
Samples were collected from small tributary streams, the lake inlet and outlet, the drinking water treatment facility intake, and the wastewater treatment facility outlet.
3:List of Experimental Equipment and Materials:
A bench-top fluorometer (Horiba Scientific Aqualog) was used for fluorescence spectra, and a handheld sonde (YSI 600R) for on-site measurements.
4:Experimental Procedures and Operational Workflow:
Samples were processed within 48 h and stored at 4?C. Fluorescence spectra were corrected for inner filter effects and normalized against the Raman water peak.
5:Data Analysis Methods:
Statistical methods included regularized logistic regression and gradient-boosted classification algorithms for predictive modeling.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Aqualog
Horiba Scientific
Generating excitation-emission matrices (EEMs) for fluorescence spectra analysis.
-
YSI 600R
YSI
Measuring dissolved oxygen, temperature, and pH on-site.
-
TOC-VCPH Total Organic Carbon Analyzer
Shimadzu
Measuring total and dissolved organic carbon in water samples.
-
HACH 2100AN Turbidimeter
HACH
Measuring turbidity in water samples.
-
Agilent 6460 triple quadrupole mass spectrometer
Agilent
Quantifying microcystin-LR in water samples.
-
Varian CP-3800 gas chromatograph
Varian
Analyzing THMs and HAAs in water samples.
-
登录查看剩余4件设备及参数对照表
查看全部