研究目的
To improve visualization of upper tract urothelial carcinomas (UTUC) using a novel ICG-Var3 pHLIP imaging agent.
研究成果
ICG-Var3 pHLIP NIRF imaging demonstrated 100% sensitivity and specificity for detecting UTUC, superior to white light examination (78.9% sensitivity). It improved diagnosis by 21.2%, identifying lesions missed by white light. Normal and benign tissues showed no uptake. pHLIP-based imaging is promising for improving UTUC evaluation and management, but further studies are required for validation and clinical application.
研究不足
The study is a small, ex-vivo feasibility study; results need validation in larger cohorts and in-vivo translation. Limitations include potential issues with ureteroscopic approaches, scope diameter, tangential viewing, and in-vivo irrigation affecting lesion identification. Comparison with other enhanced imaging techniques like PDD and NBI is needed.
1:Experimental Design and Method Selection:
The study used an ex-vivo design to evaluate the feasibility of ICG-Var3 pHLIP for imaging UTUC. The method involved irrigating specimens with the imaging agent and comparing NIRF imaging with white light examination and histopathology.
2:Sample Selection and Data Sources:
Twelve ex-vivo upper urinary tract specimens from patients undergoing surgical treatment for upper urinary tract malignancy (11 UTUC, 1 RCC as negative control) were prospectively enrolled.
3:List of Experimental Equipment and Materials:
Equipment included Stryker 1588 AIM imaging system, white light laparoscopic camera, DaVinci Si Surgical System Firefly, ureteral catheters, normal saline, PBS with D-glucose, ICG-Var3 pHLIP solution, formalin for fixation, H&E staining materials. Materials included the ICG-Var3 pHLIP agent.
4:Experimental Procedures and Operational Workflow:
Specimens were washed with saline, irrigated with ICG-Var3 pHLIP for 15 minutes, washed again, incised longitudinally, and imaged under white light and NIRF. Areas were marked and submitted for histopathology.
5:Data Analysis Methods:
Statistical analysis using Fisher's Exact Chi square test with IBM SPSS Statistics Version 20 to compare sensitivity and specificity of imaging modalities.
独家科研数据包,助您复现前沿成果,加速创新突破