研究目的
Developing novel ferrocene-based pyrazole derivatives for efficient sensing of H2O2 through electrochemical and optical methods, making use of its dual property that act as an outstanding redox mediator and an effective AIE-luminogens.
研究成果
N-arylated bisferrocene pyrazole compounds 1 and 3 exhibit dual properties as AIE-luminogens and electrocatalytically active species, enabling sensitive detection of H2O2 via fluorescence (LOD 38.8 nM and 15.9 nM) and electrochemical methods (LOD 14.4 mM and 11.6 mM). The AIE effect enhances emission in aggregated states, and the compounds show potential for applications in sensing and imaging.
研究不足
Compounds 2 and 4 showed less response in H2O2 detection due to electron-withdrawing CF3 groups. Electrochemical detection limits are in mM range, which may be less sensitive compared to fluorescence detection in nM range. The study is limited to laboratory conditions and may require further optimization for real-sample applications.
1:Experimental Design and Method Selection:
Synthesis of N-arylated bisferrocene pyrazole derivatives (1-4) via Chan-Lam cross-coupling and Buchwald-Hartwig amination reactions. Characterization using analytical and spectroscopic methods. Investigation of solvatochromism, AIE properties, and dual-mode detection of H2O2 via fluorescence and electrochemical techniques.
2:Sample Selection and Data Sources:
Compounds 1-4 synthesized from ferrocenyl pyrazole and aryl boronic acids or terephthaloyl chloride. Commercial chemicals from TCI and Sigma-Aldrich. Data from NMR, MS, UV-Vis, fluorescence, and electrochemical measurements.
3:List of Experimental Equipment and Materials:
BRUKER 400 MHz NMR spectrometer, JEOL GCMATE II GC-MS, PERKIN-ELMER CHN-2400 elemental analyzer, FEI-Tecnai G2 20 S-TWIN HR-TEM, PERKIN SHIMADZU IR spectrometer, JASCO UV-Visible spectrophotometer, Hitachi F-7000 FL Spectrophotometer, CH-Instruments Model CHI620E electrochemical workstation, screen-printed electrodes, platinum electrodes, Ag/AgCl reference electrode, solvents (CH3CN, DCM, CDCl3), supporting electrolytes ([N(C4H9-n)4]ClO4, phosphate buffer).
4:Experimental Procedures and Operational Workflow:
Synthesis via cross-coupling reactions, purification by column chromatography. Electrode preparation by drop-casting on screen-printed electrodes. Fluorescence detection in CH3CN/H2O mixtures. Electrochemical measurements in PBS with H2O2. Data collection at specified wavelengths and potentials.
5:Data collection at specified wavelengths and potentials. Data Analysis Methods:
5. Data Analysis Methods: NMR spectral analysis, UV-Vis and fluorescence spectral analysis, cyclic voltammetry data analysis (E1/2, ipa/ipc), Stern-Volmer equation for quenching, quantum yield calculation using tryptophan standard, fluorescence lifetime measurement by single photon counting.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
NMR Spectrometer
400 MHz
BRUKER
Recording 1H, 13C, and 19F NMR spectra for compound characterization
暂无现货
预约到货通知
-
GC-MS
GCMATE II
JEOL
Recording EI-Mass spectra for molecular weight determination
暂无现货
预约到货通知
-
Elemental Analyzer
CHN-2400
PERKIN-ELMER
Determining micro elemental analyses (C, H, N)
暂无现货
预约到货通知
-
HR-TEM
Tecnai G2 20 S-TWIN
FEI
Taking high-resolution transmission electron microscope images for morphology and size analysis
暂无现货
预约到货通知
-
FL Spectrophotometer
F-7000
Hitachi
Recording emission spectra for fluorescence studies
-
Electrochemical Workstation
CHI620E
CH-Instruments
Performing electrochemical measurements including cyclic voltammetry
暂无现货
预约到货通知
-
IR Spectrometer
Spectrum One
PERKIN SHIMADZU
Recording infrared spectra for vibrational mode analysis
暂无现货
预约到货通知
-
UV-Visible Spectrophotometer
JASCO
Recording UV-Visible absorption spectra
暂无现货
预约到货通知
-
Screen-Printed Electrode
Modified electrode for electrochemical detection of H2O2
暂无现货
预约到货通知
-
Silica Gel
60-120μm
Avara
Column chromatography for product purification
暂无现货
预约到货通知
-
TLC Plates
Thin layer chromatography for reaction monitoring
暂无现货
预约到货通知
-
登录查看剩余9件设备及参数对照表