Common venous renal trunk in two dogs: Multidetector computed tomographic imaging findings
摘要: In dogs, variation in the branching pattern of renal veins is rare with only few patterns reported. This report describes two unusual anomalies of the renal vein branching patterns in two dogs. In dog 1, a common renal trunk drained both kidneys, in a T-shape pattern, in the caudal vena cava after a long right perirenal course. In dog 2, a common venous trunk branched cranially from the pre-renal segment of an azygos-caudal vena cava venous trunk and divided into the renal veins in a Y-shape pattern. Proper knowledge of the possible anatomical variations in renal venous drainage may be helpful during imaging assessment and surgical planning of several canine diseases involving the abdominal vasculature and retroperitoneal space.
关键词: renal veins,caudal vena cava,gonadal veins,dog,computed tomography,angiography
更新于2025-09-23 15:22:29
-
Treating cerebrovascular diseases in hybrid operating room equipped with a robotic angiographic fluoroscopy system: level of necessity and 5-year experiences
摘要: Background A hybrid operating room (OR) equipped with robotic angiographic fluoroscopy system has become prevalent in neurosurgery. The level of necessity of the hybrid OR in treating cerebrovascular diseases (CVD) is rarely discussed. Objective The authors proposed a scoring and classification system to evaluate the cerebrovascular procedures according to the level of treatment necessity for CVD in a hybrid OR and shared our 5-year experiences. Methods From December 2009 to January 2016, the registry of cerebrovascular procedures performed in the hybrid OR was retrieved. A scoring system was used to evaluate the importance of the surgical and interventional components of a cerebrovascular procedure performed in the hybrid OR. The score of either component ranged from 1, 1.5, to 2 (1 = no role, 1.5 = supplementary or informative, 2 = important or therapeutic). The total score of a procedure was by multiplying two individual scores. Levels of necessity were classified into level A (important), level B (beneficial), and level C (replaceable). Results A total of 1027 cerebrovascular procedures were performed during this period: diagnostic angiography in 328, carotid artery stenting in 286, aneurysm coiling in 128, intra-operative DSA in 101, aspiration of ICH under image guidance in 79, intra-arterial thrombolysis/thrombectomy in 51, intracranial angioplasty/stenting in 30, hybrid surgery/serial procedures in 19, and rescue surgery during embolization in 5. According to the scoring system, hybrid surgery and serial procedures scored the highest points (2 × 2). The percentages distributed at each level: levels A (2.3%), B (17.5%), and C (80.2%). Conclusion This study conveys a concept of what a hybrid OR equipped with robotic angiographic fluoroscopy system is capable of and its potential. For cerebrovascular diseases, hybrid OR exerts its value via hybrid surgery or avoiding patient transportation in serial procedures (level A), via providing real-time high-quality angiography and image guidance (level B), which constituted about 20% of the cases. The subspecialty of the group using the hybrid OR directly reflects on the number of procedures categorized in each level. In a hybrid OR, innovative treatment strategies for difficult-to-treat CVD can be developed.
关键词: Cone-beam computed tomography,Endovascular,Hybrid surgery,Robotic angiographic fluoroscopy system,Cerebrovascular disease,Hybrid operating room,Digital subtraction angiography
更新于2025-09-23 15:22:29
-
Terahertz Differential Computed Tomography: a Relevant Nondestructive Inspection Application
摘要: In recent years, tremendous advances have been made in the choice of materials used in the industry. With weight reduction as the goal, composite and polymer materials are more and more popular but they are almost transparent to X-ray. Because of this, interest has grown in other wavelengths like terahertz (THz). Due to a difference in how X-ray and THz propagate, X-ray CT algorithms cannot be directly used. For example, THz induces refraction making the reconstruction problem nonlinear. In this paper, we present a new algorithm which complies with beam profile intensities, refraction, and reflection. It is based on linearizing the reconstruction process around a computer-aided design (CAD) model of the object to be reconstructed. The method we propose computes the deviation between the object and this model.
关键词: Terahertz computed tomography,Inverse problem,Nondestructive testing,Modeling,Monte Carlo,Refraction,Nonlinear problem,Projection simulation
更新于2025-09-23 15:22:29
-
Case Study of Empirical Beam Hardening Correction Methods for Dimensional X-ray Computed Tomography Using a Dedicated Multi-material Reference Standard
摘要: This paper presents a case study of two selected beam hardening correction methods and their effects on dimensional measurements of multi-material objects. The methods under test are empirical cupping correction (ECC) and empirical dual energy calibration (EDEC). These methods were originally developed for medical applications and their potential for the reduction of artefacts is typically only analysed based on grey value images. For testing and benchmarking of the mentioned methods for dimensional metrology, a dedicated multi-material reference standard—a multi-material hole cube—is used. This reference standard was originally developed for acceptance testing of CT systems. This paper shows a second application of this standard. The reference standard has been calibrated by tactile measurements to assess centre–centre distance errors as well as patch-based bidirectional length measurement errors on beam hardening corrected data and on uncorrected data. For the application of the method also to industrial multi-material scenarios, slight modifications of the ECC method are proposed. Practical aspects of both the ECC and the EDEC approaches as well as measurement results are analysed and discussed in detail. ECC was able to significantly improve dimensional measurements and was especially able to reduce extreme errors occurring in particular in multi-material scenarios by a factor of more than 4. EDEC, the dual-energy approach, reduced grey value inhomogeneities caused by artefacts even more. Its performance for dimensional measurements was however a little worse than ECC. EDEC data resulted in a slightly larger total range of residual measurement errors, mainly due to an elevated noise level.
关键词: Beam hardening correction,Industrial computed tomography,Multi-material measurements,Material influence,Dimensional metrology
更新于2025-09-23 15:22:29
-
Submillisievert CT angiography for carotid arteries using wide array CT scanner and latest iterative reconstruction algorithm in comparison with previous generations technologies: Feasibility and diagnostic accuracy
摘要: Objectives: To assess evaluability and diagnostic accuracy of a low dose CT angiography (CTA) protocol for carotid arteries using latest Iterative Reconstruction (IR) algorithm in comparison with standard 100 kVp protocol using previous generation CT and IR. Materials and Methods: 105 patients, referred for CTA of the carotid arteries were prospectively enrolled in our study and underwent CTA with 80 kVp and latest IR algorithm (group 1). Data were retrospectively compared with 100 consecutive patients with similar examination indications that had previously undergone CTA of carotid arteries with a standard 100 kVp protocol and a first generation IR algorithm (group 2). Image quality was evaluated with a 4-point Likert-scale. For each exam CT number, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) at level of common carotid artery (CCA), internal carotid artery (ICA) and at level of Circle of Willis and Effective Dose (ED) were evaluated. 62 Group 1 patients underwent a clinically indicated DSA and results were compared with CTA. Results: No exams reported as not diagnostic. The overall mean CT number value of all arterial segments was above 450 HU in both groups. Significant lower noise, and higher SNR and CNR values were found in group 1 in comparison with group 2 despite the use of 80 kVp. In 62-group 1 patients studied by DSA, CTA showed in a segment-based analysis a sensitivity, negative predictive value and accuracy of 100%, 100% and 99% respectively. Mean ED in group 1 was 0.54±0.1 mSv with a dose reduction up to 86%. Conclusions: CTA for carotid arteries using latest IR algorithm allows to perform exams with submillisievert radiation exposure maintaining good image quality, overall evaluability and diagnostic accuracy.
关键词: atherosclerosis,Carotid arteries,Computed Tomography Angiography,Iterative reconstruction algorithm.,dose reduction
更新于2025-09-23 15:22:29
-
Polypyrrole microcapsules loaded with gold nanoparticles: Perspectives for biomedical imaging
摘要: We report the facile preparation of polypyrrole microcapsules with a hydrophobic liquid core that is loaded with gold nanoparticles. Through the oxidative polymerization of pyrrole, the polymer is deposited onto the surface of the droplets, which results in the encapsulation of both the liquid phase and the metal nanoparticles. We demonstrate the preparation of the microcapsules loaded with organic solvents (toluene, hexane) or 2-oxoheptyl isothiocyanate (new promising anticancer agent) as the liquid cores and stable or radioactive gold nanoparticles (Au-197 or Au-198 isotopes). The resulting microcapsules have been demonstrated as promising agents for medical applications such as computed tomography or gamma imaging. Moreover, the capsules can be applied as drug carriers, which has been shown in vitro on cancer and normal cell cultures.
关键词: Targeted drug delivery,Gold nanoparticles doped with Au-198,Computed tomography,Anticancer agents,Polypyrrole microcapsules,Gamma imaging
更新于2025-09-23 15:22:29
-
Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners
摘要: Purpose: To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods: Tubes containing solutions with different concentrations of K2HPO4 were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the K2HPO4 solutions were measured. The relationship between CT number and K2HPO4 concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results: The relationship between K2HPO4 concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion: There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.
关键词: Image Processing, Computer-Assisted,Imaging, Three-Dimensional,Cone-Beam Computed Tomography
更新于2025-09-23 15:22:29
-
Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: An <i>in vitro</i> study
摘要: Purpose: To assess the effects of object position in the field of view (FOV) and application of a metal artifact reduction (MAR) algorithm on the diagnostic accuracy of cone-beam computed tomography (CBCT) for the detection of vertical root fractures (VRFs). Materials and Methods: Sixty human single-canal premolars received root canal treatment. VRFs were induced in 30 endodontically treated teeth. The teeth were then divided into 4 groups, with 2 groups receiving metal posts and the remaining 2 only having an empty post space. The roots from different groups were mounted in a phantom made of cow rib bone, and CBCT scans were obtained for the 4 different groups. Three observers evaluated the images independently. Results: The highest frequency of correct diagnoses of VRFs was obtained with the object positioned centrally in the FOV, using the MAR algorithm. Peripheral positioning of the object without the MAR algorithm yielded the highest sensitivity for the first observer (66.7%). For the second and third observers, a central position improved sensitivity, with or without the MAR algorithm. In the presence of metal posts, central positioning of the object in the FOV significantly increased the diagnostic sensitivity and accuracy compared to peripheral positioning. Conclusion: Diagnostic accuracy was higher with central positioning than with peripheral positioning, irrespective of whether the MAR algorithm was applied. However, the effect of the MAR algorithm was more significant with central positioning than with peripheral positioning of the object in the FOV. The clinical experience and expertise of the observers may serve as a confounder in this respect.
关键词: Cone-Beam Computed Tomography,Artifact,Diagnosis,Tooth Fracture
更新于2025-09-23 15:22:29
-
The Application of a New Model-Based Iterative Reconstruction in Low-Dose Upper Abdominal CT
摘要: Rationale and Objectives: To compare upper abdominal computed tomography (CT) image quality of new model-based iterative reconstruction (MBIR) with low-contrast resolution preference (MBIRNR40), conventional MBIR (MBIRc), and adaptive statistical iterative reconstruction (ASIR) at low dose with ASIR at routine-dose. Materials and Methods: Study included phantom and 60 patients who had initial and follow-up CT scans. For patients, the delay phase was acquired at routine-dose (noise index = 10 HU) for the initial scan and low dose (noise index = 20 HU) for the follow-up. The low-dose CT was reconstructed with 40% and 60% ASIR, MBIRc, and MBIRNR40, while routine-dose CT was reconstructed with 40% ASIR. CT value and noise measurements of the subcutaneous fat, back muscle, liver, and spleen parenchyma were compared using one-way ANOVA. Two radiologists used semiquantitative 7-scale (-3 to +3) to rate image quality and artifacts. Results: The phantom study revealed superior low-contrast resolution with MBIRNR40. For patient scans, the CT dose index for the low-dose CT was 3.00 ± 1.32 mGy, 75% lower than the 11.90 ± 4.75 mGy for the routine-dose CT. Image noise for the low-dose MBIRNR40 images was significantly lower than the low-dose MBIRc and ASIR images, and routine-dose ASIR images (p < 0.05). Subjective ratings showed higher image quality for low-dose MBIRNR40, with lower noise, better low-contrast resolution for abdominal structures, and finer lesion contours than those of low-dose MBIRc and ASIR images, and routine-dose ASIR images (p < 0.05). Conclusion: MBIRNR40 with low-contrast resolution preference provides significantly lower noise and better image quality than MBIRc and ASIR in low-dose abdominal CT; significantly better objective and subjective image quality than the routine-dose ASIR with 75% dose reduction.
关键词: Model-based iterative reconstruction,Abdominal CT.,X-ray computed tomography,Adaptive statistical iterative reconstruction,Radiation dose
更新于2025-09-23 15:22:29
-
Radiation dose and image quality in intraoperative CT (iCT) angiography of the brain with stereotactic head frames
摘要: Objectives Intraoperative CT (iCT) angiography of the brain with stereotactic frames is an integral part of navigated neurosurgery. Validated data regarding radiation dose and image quality in these special examinations are not available. We therefore investigated two iCT protocols in this IRB-approved study. Methods Retrospective analysis of patients, who received a cerebral stereotactic iCT angiography on a 128 slice CT scanner between February 2016 and December 2017. In group A, automated tube current modulation (ATCM; reference value 410 mAs) and automated tube voltage selection (reference value 120 kV) were enabled, and only examinations with a selected voltage of 120 kV were included. In group B, fixed parameters were applied (300 mAs, 120 kV). Radiation dose was measured by assessing the volumetric CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED). Signal-to-noise ratio (SNR) and image noise were assessed for objective image quality, visibility of arteries and grey-white differentiation for subjective image quality. Results Two hundred patients (n = 100 in each group) were included. In group A, median selected tube current was 643 mAs (group B, 300 mAs; p < 0.001). Median values of CTDIvol, DLP and ED were 91.54 mGy, 1561 mGy cm and 2.97 mSv in group A, and 43.15 mGy, 769 mGy cm and 1.46 mSv in group B (p < 0.001). Image quality did not significantly differ between groups (p > 0.05). Conclusions ATCM yielded disproportionally high radiation dose due to substantial tube current increase at the frame level, while image quality did not improve. Thus, ATCM should preferentially be disabled.
关键词: Neuronavigation,Brain,Computed tomography angiography,Radiation dosage