- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Estimation of respiratory rate using infrared video in an inpatient population: an observational study
摘要: Respiratory rate (RR) is one of the most sensitive markers of a deteriorating patient. Despite this, there is significant inter-observer discrepancy when measured by clinical staff, and modalities used in clinical practice such as ECG bioimpedance are prone to error. This study utilized infrared thermography (IRT) to measure RR in a critically ill population in the Intensive Care Unit. This study was carried out in a Single Hospital Centre. Respiratory rate in 27 extubated ICU patients was counted by two observers and compared to ECG Bioimpedance and IRT-derived RR at distances of 0.4–0.6 m and > 1 m respectively. IRT-derived RR using two separate computer vision algorithms outperformed ECG derived RR at distances of 0.4–0.6 m. Using an Autocorrelation estimator, mean bias was ? 0.667 breaths/min. Using a Fast Fourier Transform estimator, mean bias was ? 1.000 breaths/min. At distances greater than 1 m no statistically significant signal could be obtained. Over all frequencies, there was a significant relationship between the RR estimated using IRT and via manual counting, with Pearson correlation coefficients between 0.796 and 0.943 (p < 0.001). Correlation between counting and ECG-derived RR demonstrated significance only at > 19 bpm (r = 0.562, p = 0.029). Overall agreement between IRT-derived RR at distances of 0.4–0.6 m and gold standard counting was satisfactory, and outperformed ECG derived bioimpedance. Contactless IRT derived RR may be feasible as a routine monitoring modality in wards and subacute inpatient settings.
关键词: Monitoring,Critical care,Respiratory rate,Infrared,Contactless
更新于2025-09-12 10:27:22
-
[IEEE 2019 41st Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) - Berlin, Germany (2019.7.23-2019.7.27)] 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) - Optical fiber sensors for monitoring in critical care
摘要: Monitoring of key physiological and pharmacological parameters is an important part of a closed loop control system in critical care. Optical fiber sensors provide a versatile platform technology that can be easily incorporated into existing in-dwelling catheters or face masks. With appropriate functional coatings they can be used to monitor a range of relevant parameters and two different examples are presented: (i) respiration monitoring; (ii) drug level monitoring. Respiration monitoring involves monitoring of temperature and humidity in inhaled and exhaled breath. The optical fiber sensor consists of a fiber Bragg grating to measure temperature and a tip coating whose refractive index changes with humidity. The sensor is demonstrated to be able to track breath to breath changes when incorporated into a mask. Drug level monitoring is demonstrated in vitro using a long period grating coated with molecularly imprinted polymer nanoparticles that are sensitive to fentanyl. The sensor has a limit of detection of 50ng/ml.
关键词: respiration monitoring,optical fiber sensors,drug level monitoring,critical care,fentanyl
更新于2025-09-11 14:15:04