- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Optical measurements based on practical methods for detecting time-wise morphing structures
摘要: Nowadays non-contact measurement methods have become widely used systems in several fields especially robotics, aerospace, architecture, and cultural heritage. Practical devices, taken from mass markets, are increasingly being used in scientific and engineering research fields thanks to their ability to combine good accuracy with to the low-cost and ready-to-use experimental setup. In the present paper, digital image analysis (based on digital camera devices) and three-dimensional scanning technique (based on Kinect I and Kinect II sensors) are compared to evaluate their performance in detecting a time-wise shape modification. Digital camera and Kinect sensors are used to the non-contact detection of a morphing blade able to modify its geometry according to airflow temperature variation. The comparison showed the capability of the digital image technique to provide quantitative information when a proper alignment is adopted, while the three-dimensional scanning process allows the continuous blade detection useful to quantify the shape modification. Two-dimensional and three-dimensional blade shape reconstruction processes are also discussed.
关键词: Reverse Engineering,Non-contact measurement,Point cloud,Kinect sensor,Optical method,Digital image analysis
更新于2025-09-23 15:23:52
-
Quantification of the Changes in the Openness of the Major Temporal Arcade in Retinal Fundus Images of Preterm Infants With Plus Disease
摘要: PURPOSE. We tested the hypothesis that the openness of the major temporal arcade (MTA) changes in the presence of plus disease, by quanti?cation via parabolic modeling of the MTA, as well as measurement of an arcade angle for comparative analysis. Such analysis could assist in the detection and treatment of progressive retinopathy of prematurity. METHODS. Digital image processing techniques were applied for the detection and modeling of the MTA via a graphical user interface (GUI) to quantify the openness of the MTA. An arcade angle measure, based on a previously proposed method, also was obtained via the GUI for comparative analysis. The statistical signi?cance of the differences between the plus and no-plus cases for each parameter was analyzed using the P value. The area (Az) under the receiver operating characteristic curve was used to assess the diagnostic performance of each feature. RESULTS. The temporal arcade angle measure and the openness parameter of the parabolic model were used to perform discrimination of plus versus no-plus cases. Using a set of 19 cases with plus and 91 with no plus disease, Az ? 0.70 was obtained using the results of dual-parabolic modeling in screening for plus disease. The arcade angle measure provided comparable results with Az ? 0.73. CONCLUSIONS. Using our proposed image analysis techniques and software, this study demonstrates, for the ?rst time to our knowledge, that the openness of the MTA decreases in the presence of plus disease.
关键词: plus disease,computer-aided diagnosis,retinopathy of prematurity,major temporal arcade,digital image analysis
更新于2025-09-23 15:22:29