修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

2 条数据
?? 中文(中国)
  • Determination of cochineal and erythrosine in cherries in syrup in the presence of quenching effect by means of excitation-emission fluorescence data and three-way PARAFAC decomposition

    摘要: The simultaneous determination of two food colorants (cochineal (E-120) and erythrosine (E-127)) was achieved by means of excitation-emission fluorescence matrices and three-way PARAFAC decomposition together with the use of a calibration set that contained binary mixtures of both analytes. In the measured conditions, the amount of cochineal present in the sample affected the fluorescence signal of erythrosine since cochineal caused a quenching effect in the fluorescence of the other food additive. However, the signal of cochineal was not affected by the presence of erythrosine. A calibration line for erythrosine was built for each different concentration level of cochineal. The slopes of these regressions were different depending on the amount of quencher, whereas the intercepts were statistically equal to 0 at a 95% confidence level. The quantification of erythrosine was possible using the regression 'amount of cochineal' versus 'the slope of the calibration line for erythrosine'. Using this procedure, the mean of the absolute values of the relative errors in prediction for mixtures of both colorants were 5.86% (n = 10) for cochineal and 4.17% (n = 10) for erythrosine. Both analytes were unequivocally identified by the correlation between the pure spectra and the PARAFAC excitation and emission spectral loadings. Pitted cherries in syrup were analyzed. Cochineal and erythrosine were detected in those cherries at a concentration of 185.05 mg kg?1 and 10.76 mg kg?1, respectively. These concentration values were statistically equal to the ones obtained with a HPLC/DAD method.

    关键词: Erythrosine,Cochineal,PARAFAC,Excitation-emission fluorescence,Quenching effect,Cherries

    更新于2025-09-23 15:22:29

  • Procedure to build a signal transfer set, independent of the target analytes, between a portable fluorimeter based on light-emitting diodes and a master fluorimeter

    摘要: The need of performing “in situ” analytical determinations together with the availability of high-power deep UV-LEDs have led to the use of fluorescence spectroscopy. However, it is necessary to register excitation-emission matrices (EEM) to obtain three-way data which can be decomposed using parallel factor analysis for enabling the unequivocal identification of the analytes. In this context, the feasibility of transferring EEM between a portable fluorimeter based on LEDs and a master fluorimeter based on a xenon source has been recently reported without losing analytical quality. To build the transfer function, the signals of the same N samples must be recorded in the portable and in the master fluorimeter. In literature, these samples always contained the target analytes so the EEM signal transfer methodology is very limited in practice. Therefore, the challenge is to search for a set of samples whose EEM enable to perform the signal transfer without previously knowing the target analytes. The aim of this work is the design of a procedure to build N mixtures of P fluorophores so the N EEM would be optimal for the signal transfer. Five criteria have been defined a priori to identify the quality of a transfer set made up of N EEM. Then, a procedure has been designed to obtain the n mixtures of the P fluorophores “in silico” using the Pareto front of the optimal solutions and a desirability function to choose the desired N EEM. The procedure has been used to find five mixtures of the three chosen fluorophores for the signal transfer (coumarin 120, DL-Tyrosine and DL-Tryptophan) which are chemically different from the analytes of interest (enrofloxacin and flumequine) and are contained in a different matrix. These two analytes are antibiotics which have maximum residue limits set in the EU legislation in force. The correlation coefficients between the experimental reference spectra and the PARAFAC spectral loadings of the data registered with the master fluorimeter were greater than or equal to 0.999 in all cases. On the other hand, the correlation coefficients obtained with the portable fluorimeter ranged from 0.900 to 0.950 once the procedure was applied to the two antibiotics. Therefore, the unequivocal identification of the analytes was ensured.

    关键词: Excitation-emission fluorescence,Desirability function,Pareto front,PARAFAC,Signal transfer,Portable fluorimeter

    更新于2025-09-23 15:19:57