- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Fe3+-selective and sensitive “on-off” fluorescence probe based on the graphitic carbon nitride nanosheets
摘要: An effective and facile “on-off” fluorescence sensing approach for the determination of Fe3+ ion using a large area and relatively uniform size graphitic carbon nitride nanosheets (GCNS) was developed. The prepared GCNS have blue and stable emission, as well as excellent water dispersion, and were applied as an effective fluorescent probe that based on the quenched fluorescence for selective and sensitive detection of Fe3+ ion. Herein, we explain the ambiguous fluorescence quenching mechanism between the GCNS and Fe3+, which mainly springs from the redox potential and empty d orbital of Fe3+. The redox potential and unfilled d orbit of Fe3+ endow it excellent binding force with GCNS, which generates most obvious fluorescence quenching effect with respect to other metal ions. The limit of detection (LOD) for Fe3+ was found to be about 2.06 μM. Therefore, the prepared GCNS has the potential to be used as a fluorescent probe for detection.
关键词: nanosheets,fluorescence detection,g-C3N4,fluorescence quenching mechanism
更新于2025-09-23 15:21:01
-
Ratiometric fluorometric determination of silver(I) by using blue-emitting silicon- and nitrogen-doped carbon quantum dots and red-emitting N-acetyl-L-cysteine-capped CdTe quantum dots
摘要: A ratiometric fluorometric assay for silver(I) is described. The method makes use of a dually emitting quantum dot hybrid, which is composed of (a) blue-fluorescent silicon- and nitrogen-doped carbon quantum dots (CQDs), and (b) of red-emitting CdTe quantum dots (QDs) capped with N-acetyl-L-cysteine. The red-emitting CdTe QDs undergo strong and specific quenching by Ag(I), whereas the blue-emitting N,Si-CQDs are not quenched. The two kinds of QDs are mixed and used as a ratiometric fluorescent probe. A linear relationship is found between the log of intensities [(I608/I441)0/(I608/I441)] and the concentration of Ag(I) in the range from 5.0–1000 nM, and the limit of detection (at S/N = 3) is 1.7 nM. Possible interferents (including 17 general metal ions, 12 anions and fulvic acid) do not interfere with the determination. The assay was successfully used for the determination of Ag(I) in surface water and wastewater samples. The fluorescence quenching mechanism of the ratiometric assay system was also discussed in detailed.
关键词: Fluorescence quenching mechanism,Surface water,Nitrogen-doped carbon dots,Silver ions,Silicon-doped carbon dots,Wastewaters,3-Aminopropyltriethoxysilane functionalized carbon dots,Quenching efficiency,Dual-emission quantum dots hybrid,Fluorescent probe
更新于2025-09-19 17:13:59