oe1(光电查) - 科学论文

17 条数据
?? 中文(中国)
  • A mathematical model and iterative inversion for fluorescent optical projection tomography

    摘要: Solving the fluorophore distribution in a tomographic setting has been difficult because of the lack of physically meaningful and computationally applicable propagation models. This study concentrates on the direct modelling of fluorescence signals in optical projection tomography (OPT), and on the corresponding inverse problem. The reconstruction problem is solved using emission projections corresponding to a series of rotational imaging positions of the sample. Similarly to the bright field OPT bearing resemblance with the transmission X-ray computed tomography, the fluorescent mode OPT is analogous to X-ray fluorescence tomography (XFCT). As an improved direct model for the fluorescent OPT, we derive a weighted Radon transform based on the XFCT literature. Moreover, we propose a simple and fast iteration scheme for the slice-wise reconstruction of the sample. The developed methods are applied in both numerical experiments and inversion of fluorescent OPT data from a zebrafish embryo. The results demonstrate the importance of propagation modelling and our analysis provides a flexible modelling framework for fluorescent OPT that can easily be modified to adapt to different imaging setups.

    关键词: weighted Radon transform,optical projection tomography,fluorescence tomography,beam modelling,iterative reconstruction

    更新于2025-09-23 15:23:52

  • The Application of a New Model-Based Iterative Reconstruction in Low-Dose Upper Abdominal CT

    摘要: Rationale and Objectives: To compare upper abdominal computed tomography (CT) image quality of new model-based iterative reconstruction (MBIR) with low-contrast resolution preference (MBIRNR40), conventional MBIR (MBIRc), and adaptive statistical iterative reconstruction (ASIR) at low dose with ASIR at routine-dose. Materials and Methods: Study included phantom and 60 patients who had initial and follow-up CT scans. For patients, the delay phase was acquired at routine-dose (noise index = 10 HU) for the initial scan and low dose (noise index = 20 HU) for the follow-up. The low-dose CT was reconstructed with 40% and 60% ASIR, MBIRc, and MBIRNR40, while routine-dose CT was reconstructed with 40% ASIR. CT value and noise measurements of the subcutaneous fat, back muscle, liver, and spleen parenchyma were compared using one-way ANOVA. Two radiologists used semiquantitative 7-scale (-3 to +3) to rate image quality and artifacts. Results: The phantom study revealed superior low-contrast resolution with MBIRNR40. For patient scans, the CT dose index for the low-dose CT was 3.00 ± 1.32 mGy, 75% lower than the 11.90 ± 4.75 mGy for the routine-dose CT. Image noise for the low-dose MBIRNR40 images was significantly lower than the low-dose MBIRc and ASIR images, and routine-dose ASIR images (p < 0.05). Subjective ratings showed higher image quality for low-dose MBIRNR40, with lower noise, better low-contrast resolution for abdominal structures, and finer lesion contours than those of low-dose MBIRc and ASIR images, and routine-dose ASIR images (p < 0.05). Conclusion: MBIRNR40 with low-contrast resolution preference provides significantly lower noise and better image quality than MBIRc and ASIR in low-dose abdominal CT; significantly better objective and subjective image quality than the routine-dose ASIR with 75% dose reduction.

    关键词: Model-based iterative reconstruction,Abdominal CT.,X-ray computed tomography,Adaptive statistical iterative reconstruction,Radiation dose

    更新于2025-09-23 15:22:29

  • Performance of Landweber iteration algorithm in tomographic image reconstruction

    摘要: The rapid growth of computed tomography has been accompanied by equally advancing in image reconstruction algorithm also. The fundamental inverse problem is the reconstruction of a function from finitely many measurements, so pertaining to that function. The measured data are limited, and it cannot serve to determine one single correct solution. The iterative reconstruction image reconstruction algorithms have stable solution to the limited projection. In this paper, Landweber-based iteration image reconstruction is simulated and its performance is compared with different algorithm. Then, the quality of the reconstructed image is expressed in terms of mean absolute error and correlation coefficient as compared to the original image. The entire simulations are performed in Matlab tool.

    关键词: image reconstruction,computed,Landweber algorithm,tomography,limited projection,iterative reconstruction

    更新于2025-09-23 15:22:29

  • Submillisievert CT angiography for carotid arteries using wide array CT scanner and latest iterative reconstruction algorithm in comparison with previous generations technologies: Feasibility and diagnostic accuracy

    摘要: Objectives: To assess evaluability and diagnostic accuracy of a low dose CT angiography (CTA) protocol for carotid arteries using latest Iterative Reconstruction (IR) algorithm in comparison with standard 100 kVp protocol using previous generation CT and IR. Materials and Methods: 105 patients, referred for CTA of the carotid arteries were prospectively enrolled in our study and underwent CTA with 80 kVp and latest IR algorithm (group 1). Data were retrospectively compared with 100 consecutive patients with similar examination indications that had previously undergone CTA of carotid arteries with a standard 100 kVp protocol and a first generation IR algorithm (group 2). Image quality was evaluated with a 4-point Likert-scale. For each exam CT number, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) at level of common carotid artery (CCA), internal carotid artery (ICA) and at level of Circle of Willis and Effective Dose (ED) were evaluated. 62 Group 1 patients underwent a clinically indicated DSA and results were compared with CTA. Results: No exams reported as not diagnostic. The overall mean CT number value of all arterial segments was above 450 HU in both groups. Significant lower noise, and higher SNR and CNR values were found in group 1 in comparison with group 2 despite the use of 80 kVp. In 62-group 1 patients studied by DSA, CTA showed in a segment-based analysis a sensitivity, negative predictive value and accuracy of 100%, 100% and 99% respectively. Mean ED in group 1 was 0.54±0.1 mSv with a dose reduction up to 86%. Conclusions: CTA for carotid arteries using latest IR algorithm allows to perform exams with submillisievert radiation exposure maintaining good image quality, overall evaluability and diagnostic accuracy.

    关键词: atherosclerosis,Carotid arteries,Computed Tomography Angiography,Iterative reconstruction algorithm.,dose reduction

    更新于2025-09-23 15:22:29

  • Caracterización y simulación de ruido en las imágenes de PET reconstruidas con OSEM: desarrollo de un método para la generación de imágenes sintéticas

    摘要: Introduction: The goals of the study are to characterize imaging properties in 2D PET images reconstructed with the iterative algorithm ordered-subset expectation maximization (OSEM) and to propose a new method for the generation of synthetic images. Material and methods: The noise is analyzed in terms of its magnitude, spatial correlation, and spectral distribution through standard deviation, autocorrelation function, and noise power spectrum (NPS), respectively. Their variations with position and activity level are also analyzed. This noise analysis is based on phantom images acquired from 18F uniform distributions. Experimental recovery coefficients of hot spheres in different backgrounds are employed to study the spatial resolution of the system through point spread function (PSF). The NPS and PSF functions provide the baseline for the proposed simulation method: convolution with PSF as kernel and noise addition from NPS. Results: The noise spectral analysis shows that the main contribution is of random nature. It is also proven that attenuation correction does not alter noise texture but it modifies its magnitude. Finally, synthetic images of 2 phantoms, one of them an anatomical brain, are quantitatively compared with experimental images showing a good agreement in terms of pixel values and pixel correlations. Thus, the contrast to noise ratio for the biggest sphere in the NEMA IEC phantom is 10.7 for the synthetic image and 8.8 for the experimental image. Conclusions: The properties of the analyzed OSEM-PET images can be described by NPS and PSF functions. Synthetic images, even anatomical ones, are successfully generated by the proposed method based on the NPS and PSF.

    关键词: PET,Autocorrelation function,OSEM,Iterative reconstruction,Noise power spectrum,Point spread function

    更新于2025-09-23 15:22:29

  • Sparsity-induced dynamic guided filtering approach for sparse-view data toward low-dose X-ray computed tomography

    摘要: Iterative reconstruction (IR) methods that can incorporate filtering or regularization techniques have received widespread attention in many situations. Total variation (TV) regularization has proven to be a powerful tool to suppress streak artifacts and noise for sparse-view computed tomography (CT) reconstruction over 360°. However, with under-sampled projection data from limited-view (e.g., half-view) CT scanning, where the projections are further reduced, the edge structures are partly blurred, and some artifacts (such as blocky artifacts) are not effectively suppressed in TV-based results. To further improve the quality of the reconstructed image, a sparsity-induced dynamic guided image filtering reconstruction (SIDGIFR) method is proposed. Intermediate reconstruction results constrained by total difference minimization are taken as the guidance image to filter the results of projection onto convex sets (POCS) by guided image filtering. In the SIDGIFR algorithm, the guidance image is dynamically updated, which can transfer the important features (such as edge and small details) to the filtered image during the iterative process. To confirm the efficiency and feasibility of the SIDGIFR algorithm, simulated experiments and real data studies are performed. The quantitative evaluation shows that the proposed SIDGIFR method has better performance than other classical iterative reconstruction methods. What’s more, the proposed SIDGIFR algorithm can better preserve the edge structures, and suppress noise and artifacts, than the existing iterative reconstruction methods.

    关键词: computed tomography,total variation,iterative reconstruction,total difference,guided image filtering,sparse-view

    更新于2025-09-23 15:21:01

  • Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image

    摘要: In some clinical applications, prior normal-dose CT (NdCT) images are available, and the valuable textures and structure features in them may be used to promote follow-up low-dose CT (LdCT) reconstruction. This study aims to learn texture information from the NdCT images and leverage it for follow-up LdCT image reconstruction to preserve textures and structure features. Specifically, the proposed reconstruction method first learns the texture information from those patches with similar structures in NdCT image, and the similar patches can be clustered by searching context features efficiently from the surroundings of the current patch. Then it utilizes redundant texture information from the similar patches as a priori knowledge to describe specific regions in the LdCT image. The advanced region-aware texture preserving prior is termed as ‘RATP’. The main advantage of the PATP prior is that it can properly learn the texture features from available NdCT images and adaptively characterize the region-specific structures in the LdCT image. The experiments using patient data were performed to evaluate the performance of the proposed method. The proposed RATP method demonstrated superior performance in LdCT imaging compared to the filtered back projection (FBP) and statistical iterative reconstruction (SIR) methods using Gaussian regularization, Huber regularization and the original texture preserving regularization.

    关键词: texture preserving,statistical iterative reconstruction,low-dose,a priori image,CT imaging

    更新于2025-09-23 15:21:01

  • Prior-Guided Metal Artifact Reduction for Iterative X-Ray Computed Tomography

    摘要: High-attenuation materials pose significant challenges to computed tomographic (CT) imaging. Formed of high mass-density and high atomic number elements, they cause more severe beam hardening and scattering artifacts than do water-like materials. Pre-corrected line-integral density measurements are no longer linearly proportional to the path lengths, leading to reconstructed image suffering from streaking artifacts extending from metal, often along highest-density directions. In this paper, a novel prior-based iterative approach is proposed to reduce metal artifacts. It combines the superiority of statistical methods with the benefits of sinogram completion methods to estimate and correct metal-induced biases. Preliminary results show minimized residual artifacts and significantly improved image quality.

    关键词: statistical reconstruction,metal artifact reduction,beam hardening correction,computed tomography,iterative reconstruction

    更新于2025-09-23 15:19:57

  • Development of Limited-Angle Iterative Reconstruction Algorithms with Context Encoder-Based Sinogram Completion for Micro-CT Applications

    摘要: Limited-angle iterative reconstruction (LAIR) reduces the radiation dose required for computed tomography (CT) imaging by decreasing the range of the projection angle. We developed an image-quality-based stopping-criteria method with a flexible and innovative instrument design that, when combined with LAIR, provides the image quality of a conventional CT system. This study describes the construction of different scan acquisition protocols for micro-CT system applications. Fully-sampled Feldkamp (FDK)-reconstructed images were used as references for comparison to assess the image quality produced by these tested protocols. The insufficient portions of a sinogram were inpainted by applying a context encoder (CE), a type of generative adversarial network, to the LAIR process. The context image was passed through an encoder to identify features that were connected to the decoder using a channel-wise fully-connected layer. Our results evidence the excellent performance of this novel approach. Even when we reduce the radiation dose by 1/4, the iterative-based LAIR improved the full-width half-maximum, contrast-to-noise and signal-to-noise ratios by 20% to 40% compared to a fully-sampled FDK-based reconstruction. Our data support that this CE-based sinogram completion method enhances the efficacy and efficiency of LAIR and that would allow feasibility of limited angle reconstruction.

    关键词: generative adversarial network (GAN),context encoder (CE),limited-angle iterative reconstruction (LAIR)

    更新于2025-09-19 17:15:36

  • Impact of Knowledge-Based Iterative Model Reconstruction on Image Quality and Hemodynamic Parameters in Dynamic Myocardial Computed Tomography Perfusion Using Low-Tube-Voltage Scan

    摘要: Objective: Knowledge-based iterative model reconstruction (IMR) yields diagnostically acceptable image quality in low-dose static computed tomography (CT). We aimed to evaluate the feasibility of IMR in dynamic myocardial computed tomography perfusion (CTP). Methods: We enrolled 24 patients who underwent stress dynamic CTP using a 256-slice CT. Images were reconstructed using filtered back projection (FBP), hybrid IR, and IMR. Image quality and hemodynamic parameters were compared among three algorithms. Results: Qualitative image quality and contrast-to-noise ratio were significantly higher by IMR than by FBP or hybrid IR (visual score: 4.1 vs. 3.0 and 3.5; contrast-to-noise ratio: 12.4 vs. 6.6 and 8.4; P < 0.05). No significant difference was observed among algorithms in CTP-derived myocardial blood flow (1.68 vs. 1.73 and 1.70 mL/g/min). Conclusions: The use of knowledge-based iterative model reconstruction improves image quality without altering hemodynamic parameters in low-dose dynamic CTP, compared with FBP or hybrid IR.

    关键词: iterative reconstruction,myocardial blood volume,myocardial blood flow,computed tomography perfusion,mean transit time

    更新于2025-09-12 10:27:22