  • A clinical assessment of visual performance of combining the TECNIS<sup>?</sup>?Symfony?Extended Range of Vision IOL (ZXR00) with the +3.25 D TECNIS Multifocal 1-piece IOL (ZLB00) in subjects undergoing bilateral cataract extraction

    摘要: Purpose: To combine the increased depth of focus of the TECNIS? Symfony intraocular lens (IOL) with a TECNIS Multifocal (MF) low-add IOL (+3.25) to enable a patient to be less dependent on corrective lenses. Setting: Clinic in Canada. Design: Single-center, prospective, open-label. Materials and methods: Fifty patients were enrolled for bilateral surgery. Patients were implanted with TECNIS Symfony Extended Range of Focus lens in the dominant eye, and TECNIS low-add +3.25 MF IOL in the non-dominant eye. Patients were $18 years of age and had best-corrected visual acuity .20/30 in both eyes, pupil size .3.5 mm, and ,1.5 D of corneal astigmatism. Patients were evaluated preoperatively, operatively, and postoperatively on Day 1, Day 7, Month 1, and Month 3. Postoperative evaluations at Month 3 were completed by 32 of 50 patients enrolled, and included distance, intermediate and near visual acuity (VA), and subjective outcomes. Results: Three months postoperatively, binocular results without correction revealed 97% (29/30) of patients had distance VA of 20/20 or better, 97% (29/30) had intermediate VA of 20/25 or better, and 94% (28/30) had near VA of 20/25 or better. At Month 3, the majority of patients reported “none” for visual symptoms of glare (30/30, 100%), halo (29/30, 96.6%), starbursts (29/30), or other – blur (30/30, 100%). Conclusion: Three months postoperatively, the combination of the increased depth of focus of the TECNIS Symfony IOL with a TECNIS MF low-add (+3.25) IOL may provide excellent uncorrected VA at near, intermediate, and far distances with minimal ocular symptoms.

    关键词: ZLB00,low-add IOL,contralateral,TECNIS Symfony,extended range of vision,ZXR00,blended vision,multifocal IOL

    更新于2025-09-09 09:28:46

  • Clinical Evaluation of Functional Vision of +1.5 Diopters near Addition, Aspheric, Rotational Asymmetric Multifocal Intraocular Lens

    摘要: To evaluate postoperative outcomes and visual performance in intermediate distance after implantation of a +1.5 diopters (D) addition, aspheric, rotational asymmetric multifocal intraocular lens (MIOL). Patients underwent bilateral cataract surgery with implantation of an aspheric, asymmetric MIOL with +1.5 D near addition. A complete ophthalmological examination was performed preoperatively and 3 months postoperatively. The main outcome measures were monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), distance corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UNVA) and distance corrected keratometry, and manifest refraction. The Salzburg Reading Desk was used to analyze unilateral and bilateral functional vision with uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at near and intermediate distances. The study comprised 60 eyes of 30 patients (mean age, 68.30 ± 9.26 years; range, 34 to 80 years). There was significant improvement in UDVA and CDVA. Mean UIVA was 0.01 ± 0.09 logarithm of the minimum angle of resolution (logMAR) and mean DCIVA was -0.02 ± 0.11 logMAR. In Salzburg Reading Desk analysis for UIVA, the mean subjective intermediate distance was 67.58 ± 8.59 cm with mean UIVA of -0.02 ± 0.09 logMAR and mean word count of 96.38 ± 28.32 words/min. The new aspheric, asymmetric, +1.5 D near addition MIOL offers good results for distance visual function in combination with good performance for intermediate distances and functional results for near distance.

    关键词: Low-add,Presbyopia,Multifocal intraocular lens,Cataract

    更新于2025-09-09 09:28:46