The influence of minimal misalignment on the repeatability of PET images examined by the repositioning of point sources
摘要: Objective: We aimed to evaluate the influence of the minimal misalignment of the hot spot on the repeatability of PET images using the repositioning of point sources. Methods: Point sources with an inner-diameter of 1 mm were made with 1μL of 18F solution. Seven point sources were placed on the x-axis in the field-of-view. For fixed position imaging, PET data were acquired for 10 min 5 times serially. For variable position imaging, PET data were acquired for 10 minutes each with the point sources placed at 0 mm, ±0.5 mm, and ±1.0 mm in the x-axis direction. The data were reconstructed using ordered-subsets expectation maximization (OSEM) and OSEM with point-spread function (OSEM+PSF) algorithms. The image matrix was 128×128, 200×200, 256×256, 400×400, and 512×512 pixels. The normalized maximum count (rMax), the variation of rMax (CVmax) and full width at half maximum (FWHM) were analyzed. Results: The hot spots on OSEM images far from the center became faint and broad, while those on the OSEM+PSF images became small and dense. Although the rMax was overestimated at the 5 cm position on OSEM image, those at other positions were overestimated on OSEM+PSF images with a matrix size of ≥256×256. The rMax showed a similar pattern in fixed and variable position images. The CVmax in fixed position OSEM images were <2%, irrespective of the matrix size. In contrast, the CVmax in variable position images were higher in comparison to fixed position images. The CVmax of the OSEM+PSF images were higher in comparison to OSEM images. The FWHM increased at positions far from the center on OSEM image, while that was stable at all positions on OSEM+PSF images. Conclusion: The repeatability of the small hot spot was affected by the minimal misalignment, especially on the OSEM+PSF images. Precise positioning is necessary if PET is to be used as a biomarker. Professions should recognize that the PSF correction deteriorates the repeatability of the small hot spot although it improves the spatial resolution of PET images.
关键词: repositioning,repeatability,point-spread function,PET/CT
更新于2025-09-19 17:15:36
-
Identification, Characterization, and Optimization of Integrin αvβ6-Targeting Peptides from a One-Bead One-Compound (OBOC) Library: Towards the Development of Positron Emission Tomography (PET) Imaging Agents
摘要: The current translation of peptides identified through the one-bead one-compound (OBOC) technology into positron emission tomography (PET) imaging agents is a slow process, with a major delay between ligand identification and subsequent lead optimization. This work aims to streamline the development process of 18F-peptide based PET imaging agents to target the integrin αvβ6. By directly identify αvβ6–targeting peptides from a 9-mer 4-fluorobenzoyl peptide library using the on-bead two-color (OBTC) cell-screening assay, a total of 185 peptide beads were identified and 5 beads sequenced for further evaluation. The lead peptide 1 (VGDLTYLKK(FB), IC50 = 0.45 ± 0.06 μM, 25% stable in serum at 1 h) was further modified at the N-, C-, and bi-termini. C-terminal PEGylation increased the metabolic stability (>95% stable), but decreased binding affinity (IC50 = 3.7 ± 1 μM) was noted. C-terminal extension (1i, VGDLTYLKK(FB)KVART) significantly increased binding affinity for integrin αvβ6 (IC50 = 0.021 ± 0.002 μM), binding selectivity for αvβ6-expressing cells (3.1 ± 0.8:1), and the serum stability (>99% stable). Our results demonstrate the challenges in optimizing OBOC-derived peptides, indicate both termini of 1 are sensitive to modifications, and show that further modification of 1 is necessary to demonstrate utility as an 18F-peptide imaging agent.
关键词: Fluorine-18,integrin αvβ6,affinity,one-bead one-compound (OBOC),library screening,solid-phase radiolabeling,positron emission tomography (PET),selectivity
更新于2025-09-19 17:15:36
-
Rapid fabrication of silver nanoparticle/polydopamine functionalized polyester fibers
摘要: In this paper, silver nanoparticles functionalized poly(ethylene terephthalate) (PET) fibers with antimicrobial activity, electrical conductivity and good coating stability are reported. Firstly, silver plated PET fibers were fabricated by rapid polydopamine (PDA) modification followed by electroless plating. Secondly, the surface morphologies and compositions of PDA modified and silver coated PET fibers were characterized by employing scanning electron microscopy, atomic force microscopy, X-ray diffraction and energy dispersive spectrometry. Finally, the antimicrobial properties and electrical conductivity of the silver plated PET fibers were investigated. The results showed that the silver coated PET fibers exhibited excellent antimicrobial activity to both Escherichia coli and Staphylococcus aureus (with an antimicrobial efficiency of 100 and 99.99%, respectively), and that the antimicrobial activity was well maintained after washing. The silver coated PET fibers showed electrical resistance of 0.76 Ω per 1 cm, indicating good conductivity. It was also demonstrated that the silver layer that formed had good mechanical durability, as indicated by conductivity measurements during tensile loading and observation of the surface morphology of the fibers under various modes of deformation.
关键词: silver nanoparticles,electrical conductivity,antimicrobial,PET fibers,polydopamine
更新于2025-09-19 17:15:36
-
Diagnostic performance of fluorine-18 fluorodeoxyglucose positron emission tomography in the management of solitary pulmonary nodule: a meta-analysis
摘要: Background: In the setting of solitary pulmonary nodules (SPNs), fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG-PET/CT) is considered a useful non-invasive diagnostic tool though false positive (FP) and false negative (FN) results affects accuracy due to different conditions, such as inflammatory diseases or low-uptake neoplasms. Aim of this study is to evaluate overall diagnostic performance of 18F-FDG-PET/CT for malignant pulmonary nodules. Methods: A computerized research, including published articles from 2012 and 2017, was carried out. 18F-FDG-PET/CT overall sensitivity (Se), specificity (Spe), positive likelihood ratio (PLR), negative likelihood ratio (NLR), positive predictive value (PPV), negative predictive value (NPV), diagnostic index and odds ratio were pooled. No selection-bias were found according to asymmetry test. Results: A total of twelve studies were included in the meta-analysis. The pooled Se, Spe, PLR, NLR, PPV, NPV and accuracy index (AI) with relative 95% confidence intervals (CI) were 0.819 (95% CI: 0.794–0.843), 0.624 (95% CI: 0.582–0.665), 2.190 (95% CI: 1.950–2.440), 0.290 (95% CI: 0.250–0.330), 0.802 (95% CI: 0.783–0.819), 0.652 (95% CI: 0.618–0.684) and 0.649 (95% CI: 0.625–0.673), respectively. The diagnostic odds ratio (DOR) was 7.049 with a relative 95% CI between 5.550 and 8.944. Conclusions: The results suggest 18F-FDG-PET/CT has good diagnostic accuracy in SPNs evaluation; but, it should not be considered as a discriminatory test rather than a method to be included in a clinical and diagnostic pathway.
关键词: Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG-PET/CT),solitary pulmonary nodules (SPNs),lung cancer
更新于2025-09-19 17:15:36
-
A new turn-on fluorescent probe with ultra-large fluorescence enhancement for detection of hydrogen polysulfides based on dual quenching strategy
摘要: Based on dual quenching strategy (ESIPT inhibited quenching and PET quenching), we have developed a new turn-on fluorescent probe 1. Combining 3-(benzo[d]thiazol-2-yl)-10-butyl-10H-phenothiazin-2-ol (dye 2) as the fluorophore and 2-fluoro-5-nitro-benzoic as the recognition moiety, probe 1 had feature of notable large Stokes shift, highly sensitivity and selective for monitoring H2Sn with remarkable fluorescence enhancement (328-fold) response at 534 nm. Probe 1 exhibited excellent performance in the quantitative detection of H2Sn with a 137 nm Stokes shift and a low detection limit of 26 nM in solution. Finally, probe 1 was successfully utilized to image H2Sn in living A549 cells and zebrafish.
关键词: Large stokes shift,ESIPT,Hydrogen polysulfides,PET
更新于2025-09-19 17:15:36
-
An efficient new dual fluorescent pyrene based chemosensor for the detection of bismuth (III) and aluminium (III) ions and its applications in bio-imaging
摘要: A new simple pyrene based schiff base chemosensor 1 (nicotinic acid pyren-1-ylmethylene-hydrazide) has been constructed and is prepared from 1-pyrenecarboxaldehyde and nicotinic hydrazide. Notably, the chemosensor 1 exhibited remarkable colour changes while in the presence of trivalent metal ions like Bi3+ & Al3+ ion in DMSO-H2O, (1:1 v/v, HEPES = 50 mM, pH = 7.4). The UV-Vis spectral investigation of chemosensor 1 showed that the maximum absorption peak appeared at 378 nm. In emission studies, chemosensor 1 develops weak fluorescence, while upon the addition of Bi3+ and Al3+ ions, it exhibits an enhancement of fluorescence intensity. Nevertheless, rest of metal ions have no changes in the emission spectra. The association constant of chemosensor 1 for binding to Bi3+ & Al3+ system had a value of 1.27 × 104 M-1 and 1.53 × 104 M-1. The detection limits were 0.12 μM for Bi3+ and 0.17 μM for Al3+ respectively. The overall results reveal that chemosensor 1 can act as a dual-channel, highly selective, and sensitive probe for Bi3+ and Al3+ ions. Moreover, the fluorescence imaging of chemosensor 1 was applied in RAW 264.7 cell line and cytotoxicity assay prove that this chemosensor 1 is non-toxic as well as highly biocompatible.
关键词: Pyrene Schiff base,Spectroscopic studies,Live cell imaging,PET,Bi3+ and Al3+ detection
更新于2025-09-19 17:15:36
-
[Methods in Molecular Biology] Cancer Metabolism Volume 1928 (Methods and Protocols) || Imaging Cancer Metabolism with Positron Emission Tomography (PET)
摘要: Positron emission tomography (PET) enables the noninvasive spatiotemporal analysis of cancer metabolism in vivo. Both natural and nonnatural PET tracers have been developed to assess metabolic pathways during tumorigenesis, cancer progression, and metastasis. Here we describe the dynamic in vivo PET/CT imaging of the glucose analogue [18F]fluoro-2-deoxy-D-glucose (FDG), taking into consideration the methodology for alternative metabolic PET substrates.
关键词: FDG,Fluorine-18,Imaging,Positron emission tomography,PET,Carbon-11,Fluorodeoxyglucose,Mouse
更新于2025-09-19 17:15:36
-
Clinical Translation of [68Ga]Ga-NOTA-anti-MMR-sdAb for PET/CT Imaging of Protumorigenic Macrophages
摘要: Purpose: Macrophage mannose receptor (MMR, CD206) expressing tumor-associated macrophages (TAM) are protumorigenic and was reported to negatively impact therapy responsiveness and is associated with higher chances of tumor relapse following multiple treatment regimens in preclinical tumor models. Since the distribution of immune cells within the tumor is often heterogeneous, sampling errors using tissue biopsies will occur. In order to overcome this limitation, we propose positron emission tomography (PET)/X-ray computed tomography (CT) imaging using 68Ga-labeled anti-MMR single-domain antibody fragment (sdAb) to assess the presence of these protumorigenic TAM. Procedures: Cross-reactive anti-MMR-sdAb was produced according to good manufacturing practice (GMP) and conjugated to p-SCN-Bn-NOTA bifunctional chelator for 68Ga-labeling. Biodistribution and PET/CT studies were performed in wild-type and MMR-deficient 3LL-R tumor-bearing mice. Biodistribution data obtained in mice were extrapolated to calculate radiation dose estimates for the human adult using OLINDA software. A 7-day repeated dose toxicity study for NOTA-anti-MMR-sdAb was performed in healthy mice up to a dose of 1.68 mg/kg. Results: [68Ga]Ga-NOTA-anti-MMR-sdAb was obtained with 76 ± 2 % radiochemical yield, 99 ± 1 % radiochemical purity, and apparent molar activity of 57 ± 11 GBq/μmol. In vivo biodistribution analysis showed fast clearance via the kidneys and retention in MMR-expressing organs and tumor, with tumor-to-blood and tumor-to-muscle ratios of 6.80 ± 0.62 and 5.47 ± 1.82, respectively. The calculated effective dose was 0.027 mSv/MBq and 0.034 mSv/MBq for male and female, respectively, which means that a proposed dose of 185 MBq in humans would yield a radiation dose of 5.0 and 6.3 mSv to male and female patients, respectively. In the toxicity study, no adverse effects were observed. Conclusions: Preclinical validation of [68Ga]Ga-NOTA-anti-MMR-sdAb showed high specific uptake of this tracer in MMR-expressing TAM and organs, with no observed toxicity. [68Ga]Ga-NOTA-anti-MMR-sdAb is ready for a phase I clinical trial.
关键词: Single-domain antibody (sdAb),PET,Tumor-associated macrophages (TAM),Macrophage mannose receptor (MMR)
更新于2025-09-19 17:15:36
-
Synthesis and Preliminary Evaluations of a Triazole-cored Antagonist ([18F]N2B-0518) as PET Imaging Probe for GluN2B Subunit in the Brain
摘要: GluN2B is the most studied subunit of N-methyl-D-aspartate receptors (NMDARs) and implicated in the pathologies of various central nervous system disorders and neurodegenerative diseases. As pan NMDAR antagonists often produce debilitating side effects, new approaches in drug discovery have shifted to subtype-selective NMDAR modulators, especially GluN2B-selective antagonists. While positron emission tomography (PET) studies of GluN2B-selective NMDARs in the living brain would enable target engagement in drug development and improve our understanding in the NMDAR signaling pathways between normal and disease conditions, a suitable PET ligand is yet to be identified. Herein we developed an 18F-labeled potent antagonist, 2-((1-(4-[18F]fluoro-3-methylphenyl)-1H-1,2,3-triazol-4-yl)methoxy)-5-methoxypyrimidine ([18F]13; also called [18F]N2B-0518) as a PET tracer for imaging the GluN2B subunit. The radiofluorination of [18F]13 was efficiently achieved by our spirocyclic iodonium ylide (SCIDY) method. In in vitro autoradiography studies, [18F]13 displayed highly region-specific binding in brain sections of rat and non-human primate, which was in accordance with the expression of GluN2B subunit. Ex vivo biodistribution in mice revealed that [18F]13 could penetrate the blood-brain barrier with moderate brain uptake (3.60% ID/g at 2 min) and rapid washout. Altogether, this work provides a GluN2B-selective PET tracer bearing new chemical scaffold and shows high specificity to GluN2B subunit in vitro, which may pave the way for the development of a new generation of GluN2B PET ligands.
关键词: subtype-selective,PET imaging,18F-labeling,autoradiography,GluN2B subunit,spirocyclic iodonium ylide
更新于2025-09-19 17:15:36
-
[IEEE 2019 IEEE 46th Photovoltaic Specialists Conference (PVSC) - Chicago, IL, USA (2019.6.16-2019.6.21)] 2019 IEEE 46th Photovoltaic Specialists Conference (PVSC) - Spatially Resolved Material Quality Prediction Via Constrained Deep Learning
摘要: Positron emission tomography (PET) images are typically reconstructed with an in-plane pixel size of approximately 4 mm for cancer imaging. The objective of this work was to evaluate the effect of using smaller pixels on general oncologic lesion-detection. A series of observer studies was performed using experimental phantom data from the Utah PET Lesion Detection Database, which modeled whole-body FDG PET cancer imaging of a 92 kg patient. The data comprised 24 scans over 4 days on a Biograph mCT time-of-flight (TOF) PET/CT scanner, with up to 23 lesions (diam. 6–16 mm) distributed throughout the phantom each day. Images were reconstructed with 2.036 mm and 4.073 mm pixels using ordered-subsets expectation-maximization (OSEM) both with and without point spread function (PSF) modeling and TOF. Detection performance was assessed using the channelized non-prewhitened numerical observer with localization receiver operating characteristic (LROC) analysis. Tumor localization performance and the area under the LROC curve were then analyzed as functions of the pixel size. In all cases, the images with ~2 mm pixels provided higher detection performance than those with ~4 mm pixels. The degree of improvement from the smaller pixels was larger than that offered by PSF modeling for these data, and provided roughly half the benefit of using TOF. Key results were confirmed by two human observers, who read subsets of the test data. This study suggests that a significant improvement in tumor detection performance for PET can be attained by using smaller voxel sizes than commonly used at many centers. The primary drawback is a 4-fold increase in reconstruction time and data storage requirements.
关键词: PET/CT reconstruction,PET/CT,image reconstruction,Image quality assessment
更新于2025-09-19 17:13:59