  • Study of Sensitivity and Resolution for Full Ring PET Prototypes based on Continuous Crystals and analytical modeling of the light distribution

    摘要: Sensitivity and spatial resolution are the main parameters to maximize in the performance of a PET scanner. For this purpose, detectors consisting of a combination of continuous crystals optically coupled to segmented photodetectors have been employed. With the use of continuous crystals the sensitivity is increased with respect to the pixelated crystals. In addition, spatial resolution is no longer limited to the crystal size. The main drawback is the difficulty in determining the interaction position. In this work, we present the characterization of the performance of a full ring based on cuboid continuous crystals coupled to SiPMs. To this end, we have employed the simulations developed in a previous work for our experimental detector head. Sensitivity could be further enhanced by using tapered crystals. This enhancement is obtained by increasing the solid angle coverage, reducing the wedge-shaped gaps between contiguous detectors. The performance of the scanners based on both crystal geometries was characterized following NEMA NU 4-2008 standardized protocol in order to compare them. An average sensitivity gain over the entire axial field of view of 13.63% has been obtained with tapered geometry while similar performance of the spatial resolution has been proven with both scanners. The activity at which NECR and True peak occur is smaller and the peak value is greater for tapered crystals than for cuboid crystals. Moreover, a higher degree of homogeneity was obtained in the sensitivity map due to the tighter packing of the crystals, which reduces the gaps and results in a better recovery of homogeneous regions than for the cuboid configuration. Some of the results obtained, such as spatial resolution, depend on the interaction position estimation and may vary if other method is employed.

    关键词: NEMA NU 4-2008,Monte Carlo simulations,image reconstruction,continuous crystals,depth of interaction,positron emission tomography (PET)

    更新于2025-09-04 15:30:14

  • Confidence interval constraint based regularization framework for PET quantization

    摘要: In this paper, a new generic regularized reconstruction framework based on confidence interval constraints for tomographic reconstruction is presented. As opposed to usual state-of-the-art regularization methods that try to minimize a cost function expressed as the sum of a data-fitting term and a regularization term weighted by a scalar parameter, the proposed algorithm is a two-step process. The first step concentrates on finding a set of images that relies on direct estimation of confidence intervals for each reconstructed value. Then, the second step uses confidence intervals as a constraint to choose the most appropriate candidate according to a regularization criterion. Two different constraints are proposed in this paper. The first one has the main advantage of strictly ensuring that the regularized solution will respect the interval-valued data-fitting constraint, thus preventing over-smoothing of the solution while offering interesting properties in terms of spatial and statistical bias/variance trade-off. Another regularization proposition based on the design of a smoother constraint also with appealing properties is proposed as an alternative. The competitiveness of the proposed framework is illustrated in comparison to other regularization schemes using analytical and GATE-based simulation and real PET acquisition.

    关键词: confidence intervals,constrained regularization,Image reconstruction,total variation,positron emission tomography

    更新于2025-09-04 15:30:14

  • Fluorine-18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Diagnosis and Assessment of Takayasu Arteritis and Ulcerative Colitis

    摘要: Takayasu arteritis (TA) and ulcerative colitis (UC), both immune-mediated inflammatory diseases, rarely occur together. This report describes TA in a 29-year old female patient who was being treated for UC for three years. As she had left-side neck pain and headache, she was diagnosed with TA and her response to tumor necrosis factor (TNF) inhibitor was assessed by fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT). Positive responses to the TNF inhibitor were seen by PET/CT for the TA and by endoscopy for the UC. We conclude that TNF inhibitors are effective treatments for both TA and UC. We found that PET/CT is a useful for diagnosing and assessing TA.

    关键词: Positron emission tomography,Ulcerative colitis,Takayasu arteritis

    更新于2025-09-04 15:30:14