- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Microvascular blood flow velocities measured with a retinal function imager: inter-eye correlations in healthy controls and an exploration in multiple sclerosis
摘要: Background: The retinal microcirculation has been studied in various diseases including multiple sclerosis (MS). However, inter-eye correlations and potential differences of the retinal blood flow velocity (BFV) remain largely unstudied but may be important in guiding eye selection as well as the design and interpretation of studies assessing or utilizing retinal BFV. The primary aim of this study was to determine inter-eye correlations in BFVs in healthy controls (HCs). Since prior studies raise the possibility of reduced BFV in MS eyes, a secondary aim was to compare retinal BFVs between MS eyes, grouped based on optic neuritis (ON) history and HC eyes. Methods: Macular arteriole and venule BFVs were determined using a retinal function imager (RFI) in both eyes of 20 HCs. One eye from a total of 38 MS patients comprising 13 eyes with ON (MSON) and 25 eyes without ON (MSNON) history were similarly imaged with RFI. Results: OD (right) and OS (left) BFVs were not significantly different in arterioles (OD: 3.95 ± 0.59 mm/s; OS: 4.08 ± 0.60 mm/s, P = 0.10) or venules (OD: 3.11 ± 0.46 mm/s; OS: 3.23 ± 0.52 mm/s, P = 0.06) in HCs. Very strong inter-eye correlations were also found between arteriolar (r = 0.84, P < 0.001) and venular (r = 0.87, P < 0.001) BFVs in HCs. Arteriolar (3.48 ± 0.88 mm/s) and venular (2.75 ± 0.53 mm/s) BFVs in MSNON eyes were significantly lower than in HC eyes (P = 0.009 and P = 0.005, respectively). Similarly, arteriolar (3.59 ± 0.69 mm/s) and venular (2.80 ± 0.45 mm/s) BFVs in MSON eyes were also significantly lower than in HC eyes (P = 0.046 and P = 0.048, respectively). Arteriolar and venular BFVs in MSON and MSNON eyes did not differ from each other (P = 0.42 and P = 0.48, respectively). Conclusions: Inter-eye arteriolar and venular BFVs do not differ significantly in HCs and are strongly correlated. Our findings support prior observations that arteriolar and venular BFVs may be reduced in MS eyes. Moreover, this seems to be the case in both MS eyes with and without a history of ON, raising the possibility of global blood flow alterations in MS. Future larger studies are needed to assess differences in BFVs between MSON and MSNON eyes.
关键词: Blood flow velocity,Neurology,Multiple sclerosis,Optic neuropathy,Inter-eye correlation,Retinal function imager
更新于2025-09-11 14:15:04
-
Assesment of Conjunctival Microangiopathy in a Patient with Diabetes Mellitus Using the Retinal Function Imager
摘要: Diabetes mellitus (DM) is notorious for causing retinal microangiopathy, but bulbar conjunctival microangiopathy (CM) mirroring the established retinal vessel changes, has also been observed. Recent studies suggest that CM occurs in all DM patients in various degrees depending on disease severity and occur even before non-proliferative retinopathy develops. Thus, CM might provide a means of early detection or even form a basis for early intervention of disease progression in DM patients. Herein we present - to our knowledge for the first time-the feasibility and applicability in diagnostic imaging of CM in a diabetic patient using a commercially available Retinal Function Imager (RFI, Optical Imaging Ltd, Rehovot, Israel).
关键词: Retinal function imager,Optical imaging,Diabetes mellitus,Conjunctival microangiopathy,Retinal microangiopathy
更新于2025-09-09 09:28:46