  • Red-Free Light for Measurement of Intraocular Pressure Using Goldmann Applanation Tonometer without Fluorescein

    摘要: Purpose: To evaluate the use of red-free light for the measurement of intraocular pressure (IOP) using a Goldmann applanation tonometer without fluorescein. Methods: This cross-sectional study was carried out on 500 eyes in 250 patients attending the Ophthalmology Outpatient Clinic at Suez Canal University Hospital. The IOP was measured using a Goldmann applanation tonometer mounted on a Haag-Streit slit-lamp. The measurements were performed first using red-free light without fluorescein. Then the measurements were repeated with cobalt blue light and topical fluorescein on the same eyes. Results: The mean IOP was 15.23 ± 3.3 (SD) mm Hg using the red-free light without fluorescein, whereas it was 15.78 ± 3.7 (SD) mm Hg when measured using cobalt blue light after the application of fluorescein to the conjunctival sac. This difference was not statistically significant. Conclusions: Measurement of IOP with a Goldmann applanation tonometer with red-free light and without the use of fluorescein is simple, saves time, and gives an accurate IOP measurement relative to the traditional measurement technique with cobalt blue light and topical fluorescein.

    关键词: Red-free light,Intraocular pressure,Goldmann applanation tonometer

    更新于2025-09-23 15:22:29

  • Comparison of variation of intraocular pressure in noncontact tonometry in patients subjected to phacoemulsification and trabeculectomy with phacoemulsification

    摘要: Objective: Evaluate the pattern of intraocular pressure (IOP) variations through the pneumatic tonometer, between two specific surgical techniques, and the possible variables that may influence the behavior of this pressure. Methods: Retrospective cross-sectional study carried out through the review of electronic medical records of a private ophthalmological reference hospital in the city of Goiania, Goiás, Brazil, from 2012 to 2016, comprising of a sample of 550 eyes. The analyzed variables were, age, gender, IOP, axis, pachymetry, anterior chamber depth, and axial length. Results: In the end, the study consisted of 231 eyes, represented by 179 patients. Of these, 182 eyes were operated on by isolated cataract surgery, with a mean age of 72.0±9.5 years. The combined surgery represented a total of 49 eyes, 34 patients with a mean age of 71.9±8.14 years. There was statistical significance (P,0.05) in correlating the pre- and postoperative IOP values in the 24-hour, 7-, 15-day, and 12-month postoperative periods. Conclusion: A standard of variation of IOP was found through the pneumatic tonometer in both surgical techniques, but a more significant reduction was observed in combined surgery than in isolated cataract surgery, and further studies with a greater epidemiological impact are required for confirmation of this conclusion.

    关键词: pneumatic tonometer,cataract,glaucoma,intraocular pressure

    更新于2025-09-10 09:29:36

  • A new device to noninvasively estimate the intraocular pressure produced during ocular compression

    摘要: To describe a noninvasive instrument that estimates intraocular pressure during episodes of external globe compression and to demonstrate the accuracy and reliability of this device by comparing it to the intraocular pressures simultaneously and manometrically measured in cannulated eyes. A thin fluid-filled bladder was constructed from flexible and inelastic plastic sheeting and was connected to a pressure transducer with high pressure tubing. The output of the pressure transducer was sent to an amplifier and recorded. This device was validated by measuring induced pressure in the fluid-filled bladder while digital pressure was applied to one surface, and the other surface was placed directly against a human cadaver eye or in vivo pig eye. The human cadaver and in vivo pig eyes were each cannulated to provide a manometric intraocular pressure control. The measurements obtained with the newly described device were within ~5% of simultaneously measured manometric intraocular pressures in both a human cadaver and in vivo pig eye model for a pressure range of ~15–100 mmHg. This novel noninvasive device is useful for estimating the intraocular pressure transients induced during any form of external globe compression; this is a clinical setting where no other devices can be used to estimate intraocular pressure.

    关键词: ocular compression,tonometer,glaucoma,intraocular pressure

    更新于2025-09-10 09:29:36

  • Review: Measurement Techniques for Intraocular Pressure

    摘要: The literature on intra-ocular pressure dynamics is reviewed, including tonometer design and calibration, the influence of corneal-scleral mechanics, and scleral rigidity factors. Drugs that influence the outflow facility of the trabecular meshwork (TM) are discussed. Transmural pressure drop across the lamina cribosa (LC) is an important parameter, in terms of quantifying potential glaucoma damage to the optic nerve.

    关键词: Glaucoma,Ocular rigidity,Calibration,Intraocular pressure,Tonometer

    更新于2025-09-10 09:29:36