Effect of UV wavelength on humic acid degradation and disinfection by-product formation during the UV/chlorine process
摘要: The efficiency of the ultraviolet (UV)/chlorine process strongly depends on UV wavelength because chlorine photolysis and its subsequent radical formation are highly wavelength-dependent. This study compared the degradation of humic acid (HA) during the UV/chlorine process by low pressure mercury lamp (LPUV, 254 nm) and ultraviolet light-emitting diode (UV-LED, 275 and 310 nm). The results indicated that HA degradation followed the pseudo-first-order kinetics, and the fluence-based degradation rate constants (kobs) were significantly affected by UV wavelength and solution pH. HA degradation decreased greatly with increasing solution pH during the UV/chlorine process at 254 nm, while the opposite trend was observed at 275 and 310 nm. In the meantime, kobs decreased in the order of 275 nm > 254 nm > 310 nm at pH > 7.0. The changes of chlorine molar absorption coefficients at different UV wavelengths resulted in the variation of chlorine photodecay rates (kobs, chlorine), and the synergistic effects of kobs, chlorine and chlorine quantum yields (Φchlorine) affected HA reduction. The formation of disinfection by-products (DBPs) during the UV/chlorine process was also evaluated. A significant suppression on DBP formation and DBP-associated calculated theoretical cytotoxicity were observed at 275 nm high UV fluence and alkaline pHs. These findings in this study demonstrate that UV wavelength at 275 nm is more suitable for HA degradation by the UV/chlorine advanced oxidation process in practical applications.
关键词: Disinfection by-products,Ultraviolet light-emitting diode (UV-LED),UV/chlorine,Humic acid,Toxicity,UV wavelength
更新于2025-11-19 16:46:39
-
Multiwell plates for obtaining a rapid microbial dose-response curve in UV-LED systems
摘要: UV light-emitting diodes (UV-LEDs) have emerged as a new technology for water disinfection. Multiwell plates are a common tool in biological research, but they have never been used for UVC/UVB-inactivation experiments of microorganisms. In this study, a novel, rapid and simple UVC/UVB-inactivation assay was developed for a UV-LED system using a multiwell plate setup (96- and 24-well plates). The relative incident irradiance distribution across the exposed area was examined by spectroradiometry and nitrate-nitrite uniformity assay. The two methods showed a good correlation and high distribution factors (> 0.89 and > 0.94 for 96- and 24-well plates, respectively). In addition, the potential of the new system for determining disinfection efficacy of E. coli and MS2 coliphage by UV-LEDs emitting at central wavelengths of 265 nm and 285 nm was demonstrated. The inactivation rate constants were comparable to those obtained using UV-LED systems with the conventional dish (or beaker) setup, but the multiwell plate method allowed for many more repetitions. The proposed system is an alternative for UV-inactivation dose-response assay, especially when screening assays are desired, since it has the advantage of being fast, comprehensive (with a large number of simultaneous replicates) and easily adapted to various applications as UV-LED based photocatalysis experiments, UV effect on biofilm formation and UV-based AOP degradation experiments.
关键词: Water treatment,MS2 coliphage,UV light-emitting diode (UV-LED),E. coli,Multiwell plate
更新于2025-09-23 15:19:57