- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Activity of frontal pole cortex reflecting hedonic tone of food and drink: fNIRS study in humans
摘要: Cognitive and hedonic aspects of taste have been studied using different neuroimaging techniques in humans. However, the methods used are unsuitable for easy monitoring of hedonics induced by intake of foods and beverages. Here we have tried to monitor changes in oxygenated hemoglobin (oxyHb) levels in the anterior prefrontal cortex (aPFC, frontopolar cortex, Brodmann area 10) in response to intake of hedonically different edibles in healthy adults. When subjects tasted sweet and bitter solutions freely without any particular instruction, cortical activation varied greatly among subjects and between the two stimuli, and no consistent results were obtained. Subjects then ate or drank preferred (hedonically positive) and disliked (hedonically negative) edibles. Although these stimuli differed among subjects, hedonically positive stimuli decreased oxyHb, whereas hedonically negative stimuli increased oxyHb, particularly in the ventral aPFC. When subjects tasted 4 kinds of jellies with different flavors and evaluated the degree of pleasantness, oxyHb level in the ventral region correlated negatively with pleasantness score. These results revealed that pleasant and unpleasant edibles tended to elicit decreased and increased oxyHb levels, respectively, within the ventral aPFC, suggesting that monitoring of oxyHb in this region may prove useful for objective evaluation of pleasantness of food and drink.
关键词: food and drink,fNIRS,oxygenated hemoglobin,anterior prefrontal cortex,hedonic tone
更新于2025-09-11 14:15:04
-
Using prerecorded hemodynamic response functions in detecting prefrontal pain response: a functional near-infrared spectroscopy study
摘要: Currently, there is no method for providing a nonverbal objective assessment of pain. Recent work using functional near-infrared spectroscopy (fNIRS) has revealed its potential for objective measures. We conducted two fNIRS scans separated by 30 min and measured the hemodynamic response to the electrical noxious and innocuous stimuli over the anterior prefrontal cortex (aPFC) in 14 subjects. Based on the estimated hemodynamic response functions (HRFs), we first evaluated the test–retest reliability of using fNIRS in measuring the pain response over the aPFC. We then proposed a general linear model (GLM)-based detection model that employs the subject-specific HRFs from the first scan to detect the pain response in the second scan. Our results indicate that fNIRS has a reasonable reliability in detecting the hemodynamic changes associated with noxious events, especially in the medial portion of the aPFC. Compared with a standard HRF with a fixed shape, including the subject-specific HRFs in the GLM allows for a significant improvement in the detection sensitivity of aPFC pain response. This study supports the potential application of individualized analysis in using fNIRS and provides a robust model to perform objective determination of pain perception.
关键词: test–retest reliability,detection sensitivity,hemodynamic response function,anterior prefrontal cortex,pain,near-infrared spectroscopy
更新于2025-09-10 09:29:36