  • <p>Effectiveness and Safety of Long Duration versus Short Duration Diode Laser Transscleral Cyclophotocoagulation</p>

    摘要: Purpose: To compare the efficacy and safety of diode laser transscleral cyclophotocoagulation using either the long duration or short duration protocol. Methods: Retrospective series of 23 consecutive patients with glaucoma who underwent continuous-wave diode laser transscleral cyclophotocoagulation from August 2016 to July 2018 at a tertiary hospital in Hong Kong. Laser pulse duration for the long and short duration protocols was defined as 3.0–4.0 and 1.5–2.0 s, respectively. Results: There were 15 male and 8 female Chinese subjects (23 eyes), age 49–90 (71.3 ± 2.7), with 10 subjects that underwent long duration cyclophotocoagulation (power 1239.2 ± 78.3 mW, spots 13.9 ± 1.4) and 13 subjects that had short duration cyclophotocoagulation (mean power 1817.3 ± 85.7 mW, spots 14.4 ± 1.0). Six months after long and short duration cyclophotocoagulation, intraocular pressure decreased significantly from 29.9 ± 7.8 to 21.1 ± 6.5 (p < 0.01), and from 35.4 ± 2.7 to 24.1 ± 3.4 (p = 0.04), respectively, while glaucoma medications decreased significantly by 1.4 ± 0.5 (p = 0.02) in the long duration group only. Reduction of medications after short duration cyclophotocoagulation was less and did not reach statistical significance (0.9 ± 0.9, p = 0.15). There was no significant difference of visual deterioration and complication rates. Conclusion: Both types of cyclophotocoagulation were equally effective in lowering intraocular pressure by 6 months, but the short duration protocol, using higher laser power, was able to achieve a greater and earlier reduction, at 3 months. However, the long duration protocol, using less laser power, appears better at reducing medication requirement by 6 months.

    关键词: g-probe,cycloablation,cyclodiode,cyclodestructive,cyclodestruction

    更新于2025-09-19 17:13:59

  • Safety and Efficacy of Diode Laser Transscleral Cyclophotocoagulation in Eyes With Good Visual Acuity

    摘要: The main aim of this study was to evaluate the safety and efficacy of diode laser transscleral cyclophotocoagulation (TSCPC) in eyes with good visual acuity. A retrospective chart review identified patients who underwent TSCPC for uncontrolled intraocular pressure (IOP) from 2014 to 2016. Enrollment criteria included pretreatment best-corrected visual acuity (BCVA) of 20 of 40 or better, and a minimum of 6 months of postoperative follow-up. Thirty-three eyes of 33 patients(mean age, 72.1 ± 16.0 y) were enrolled (mean follow-up 12.6 ± 6.1 mo). The mean (SD) IOP was reduced 48.3% from 27.1 mm Hg (7.8) at baseline to 13.1 mm Hg (4.2) at last follow-up. Reduction of ≥ 1 glaucoma medications was achieved in 17 eyes (51.5%) at last follow-up. The cumulative probability of complete success (BCVA loss <2 Snelling lines, 20% reduction IOP, no reoperation for glaucoma, no IOP < 5 mm Hg) was 78.8% and 50% at months 6 and 12, respectively. The cumulative probability of qualified success (BCVA ≥ 2 lines with ≥ 20% reduction IOP, no reoperation for glaucoma, no IOP < 5 mm Hg) was 90.1% and 81.3% at month 6 and 1 year, respectively. Significant vision loss, defined as BCVA ≥ 2 lines, occurred in 33% of patients. The most common complications were postoperative iritic (56.3%) and cystoid macular edema (12.5%). TSCPC demonstrates a strong reduction in IOP and glaucoma medication use. However, with significant vision loss in 33% of patients, future prospective studies with a comparison group receiving traditional glaucoma surgery are needed to determine comparative safety and efficacy.

    关键词: transscleral cyclophotocoagulation,diode laser,visual acuity,cyclodestruction