  • Incidence of late-acquired stent malapposition of drug eluting stents with second generation permanent and biodegradable polymer coatings-A prospective, randomized comparison using optical coherence tomography

    摘要: Objectives and Background: Polymer coatings of drug-eluting stents (DES) may induce allergic reactions and inflammation, resulting in late-acquired stent malapposition (LASM) with the risk of stent thrombosis. This study evaluated, if biodegradable polymer (BP) reduces the incidence of LASM compared to permanent polymer (PP) after treatment with newer generation DES. Methods and Results: Fifty patients with 59 lesions were randomized (2:1) to elective treatment with second generation PP-DES (n = 32, 39 stents), either Everolimus-eluting or Zotarolimus-eluting stents, or with BP-DES (Biolimus-eluting stents [BES]; n = 18, 20 stents) and underwent optical coherence tomography directly after implantation and after 1 year. After implantation acute stent malappositions (ASM) were documented in 30 stents (51%) distributed to 22 stents treated with PP-DES (56%) and 8 with BP-DES (40%; n.s.). After 1 year, late stent malappositions (LSM) were detected in 14 stents (24 %); ASM persisted (APSM) in 9 stents after one year (7 PP-DES—18%, 2 BES—10%), whereas ASM resolved in 21 stents. In addition, LASM was documented in nine stents including five stents without and four stents with additional APSM. All LASM were located in PP-DES (n = 9; 23%), none in BP-DES (P = 0.022). Compared to the reference lumen area, in-stent lumen area of stents without LASM was smaller due to neointimal hyperplasia (P = 0.021), whereas in-stent lumen area at maximum LASM of stents with LASM was larger due to positive remodeling (P = 0.002). Conclusions: In conclusion the use of BP-DES reduced the occurrence of LASM due to positive remodeling compared to second generation PP-DES.

    关键词: malapposition,permanent polymer,drug eluting stents,optical coherence tomography,biodegradable polymer

    更新于2025-09-23 15:21:01

  • Early Follow-Up Optical Coherence Tomographic Findings of Significant Drug-Eluting Stent Malapposition

    摘要: BACKGROUND: Using optical coherence tomography, we evaluated early follow-up findings of significant stent malapposition (SSM) in patients treated with second-generation drug-eluting stent. METHODS AND RESULTS: From the DETECT-OCT randomized trial (Determination of the Duration of the Dual Antiplatelet Therapy by the Degree of the Coverage of the Struts on Optical Coherence Tomography From the Randomized Comparison Between Everolimus- Versus Biolimus-Eluting Stent), a total of 386 patients (390 lesions) who underwent both postintervention and 3-month follow-up optical coherence tomography examinations were included for the present analysis. SSM was defined as a stent that had a strut with a maximal wall-to-strut distance of ≥200 μm. Postintervention, SSM was detected in 175 lesions (44.9%), including 117 lesions with a maximal wall-to-strut distance of ≥200 to <400 μm and 58 lesions with a maximal wall-to-strut distance of ≥400 μm. As the implanted stent diameter-to-reference vessel diameter ratio grew, the risk of postintervention SSM dropped (odds ratio, 0.587; 95% CI, 0.367–0.941; P=0.0398). The optimal value that best separated SSM from non-SSM postintervention was a stent diameter-to-reference vessel diameter ratio of 1.0. At 3 months follow-up, the frequency of SSM decreased from 44.9% to 33.6% (131 lesions; P=0.0001), mainly driven by the decrease in lesions with a maximal wall-to-strut distance of ≥200 to <400 μm. As the maximal wall-to-strut distance on postintervention optical coherence tomography was larger, the risk of 3-month SSM increased (odds ratio, 1.607; 95% CI, 1.131–2.286; P=0.0284). The optimal value that best separated SSM from non-SSM at 3 months follow-up was a maximal wall-to-strut distance postintervention of 230 μm. CONCLUSIONS: A spontaneous decrease in SSM was observed early in this qualified study with a large number of study patients treated with second-generation drug-eluting stent.

    关键词: optical coherence tomography,drug-eluting stents,coronary artery disease

    更新于2025-09-04 15:30:14