  • Real-time signal processing of photoplethysmographic signals to estimate the on-demand and continuous heart rate by spectral analysis

    摘要: In healthcare applications, heart rate is one of the vital signs which give the health informatics of a person. Nowadays, the evolution of PPG sensors help to develop low cost heart rate monitoring devices with minimal hardware resources compared to ECG. In this paper, an efficient algorithm is proposed to find the heart rate using frequency spectrum analysis on PPG signals. Using the proposed algorithm, the heart rate is calculated with a pass percentage of 99.2, mean absolute percentage error (MAPE) of 1.59%, mean absolute error (MAE) of 1.20 BPM and reference closeness factor (RCF) of 0.989. The first reliable heart rate output comes in 6.5th second, which is the minimum possible time. The algorithm operates with a speed of 2 MIPS and with a memory of 18 KB. So the proposed method can be integrated to any low cost real-time embedded platforms to accurately measure the heart rate.

    关键词: PPG,fast Fourier transform,heart rate,smoothing,frequency domain,FFT,photoplethysmography,decimation

    更新于2025-09-23 15:23:52

  • Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study

    摘要: Objective: To investigate the efficacy of motion-correction algorithm (MCA) in improving coronary artery image quality and measurement accuracy using an anthropomorphic dynamic heart phantom and 256-detector row computed tomography (CT) scanner. Materials and Methods: An anthropomorphic dynamic heart phantom was scanned under a static condition and under heart rate (HR) simulation of 50–120 beats per minute (bpm), and the obtained images were reconstructed using conventional algorithm (CA) and MCA. We compared the subjective image quality of coronary arteries using a four-point scale (1, excellent; 2, good; 3, fair; 4, poor) and measurement accuracy using measurement errors of the minimal luminal diameter (MLD) and minimal luminal area (MLA). Results: Compared with CA, MCA significantly improved the subjective image quality at HRs of 110 bpm (1.3 ± 0.3 vs. 1.9 ± 0.8, p = 0.003) and 120 bpm (1.7 ± 0.7 vs. 2.3 ± 0.6, p = 0.006). The measurement error of MLD significantly decreased on using MCA at 110 bpm (11.7 ± 5.9% vs. 18.4 ± 9.4%, p = 0.013) and 120 bpm (10.0 ± 7.3% vs. 25.0 ± 16.5%, p = 0.013). The measurement error of the MLA was also reduced using MCA at 110 bpm (19.2 ± 28.1% vs. 26.4 ± 21.6%, p = 0.028) and 120 bpm (17.9 ± 17.7% vs. 34.8 ± 19.6%, p = 0.018). Conclusion: Motion-correction algorithm can improve the coronary artery image quality and measurement accuracy at a high HR using an anthropomorphic dynamic heart phantom and 256-detector row CT scanner.

    关键词: Heart rate,Tomography,X-ray computed,Coronary vessels,Phantoms,Imaging,Motion-correction algorithm

    更新于2025-09-23 15:23:52

  • Second-generation motion correction algorithm improves diagnostic accuracy of single-beat coronary CT angiography in patients with increased heart rate

    摘要: Objective To assess the effect of a second-generation motion correction algorithm on the diagnostic accuracy of coronary computed tomography angiography (CCTA) using a 256-detector row CT in patients with increased heart rates. Methods Eighty-one consecutive symptomatic cardiac patients with increased heart rates (≥ 75 beats per min) were enrolled. All patients underwent CCTA and invasive coronary angiography (ICA). CCTA was performed with a 256-detector row CT using prospectively ECG-triggered single-beat protocol. Images were reconstructed using standard (STD) algorithm, first-generation intra-cycle motion correction (MC1) algorithm, and second-generation intra-cycle motion correction (MC2) algorithm. The image quality of coronary artery segments was assessed by two experienced radiologists using a 4-point scale (1: non-diagnostic and 4: excellent), according to the 18-segment model. Diagnostic performance for segments with significant lumen stenosis (≥ 50%) was compared between STD, MC1, and MC2 by using ICA as the reference standard. Results The mean effective dose of CCTA was 1.0 mSv. On per-segment level, the overall image quality score and interpretability were improved to 3.56 ± 0.63 and 99.2% due to the use of MC2, as compared to 2.81 ± 0.85 and 92.5% with STD and 3.21 ± 0.79 and 97.2% with MC1. On per-segment level, compared to STD and MC1, MC2 improved the sensitivity (92.2% vs. 79.2%, 80.7%), specificity (97.8% vs. 82.1%, 90.8%), positive predictive value (89.9% vs. 48.4%, 65.1%), negative predictive value (98.3% vs. 94.9%, 95.7%), and diagnostic accuracy (96.8% vs. 81.5%, 89.0%). Conclusion A second-generation intra-cycle motion correction algorithm for single-beat CCTA significantly improves image quality and diagnostic accuracy in patients with increased heart rate.

    关键词: Coronary angiography,Heart rate,Tomography, X-ray computed,Coronary vessels,Motion

    更新于2025-09-23 15:23:52

  • [IEEE 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) - Honolulu, HI (2018.7.18-2018.7.21)] 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) - Remote Heart Rate Measurement from RGB-NIR Video Based on Spatial and Spectral Face Patch Selection

    摘要: In this paper, we propose a novel heart rate (HR) estimation method using simultaneously recorded RGB and near-infrared (NIR) face videos. The key idea of our method is to automatically select suitable face patches for HR estimation in both spatial and spectral domains. The spatial and spectral face patch selection enables us to robustly estimate HR under various situations, including scenes under which existing RGB camera-based methods fail to accurately estimate HR. For a challenging scene in low light and with light fluctuations, our method can successfully estimate HR for all 20 subjects (±3 beats per minute), while the RGB camera-based methods succeed only for 25% of the subjects.

    关键词: spectral domain,remote sensing,spatial domain,face patch selection,heart rate estimation,RGB-NIR video

    更新于2025-09-23 15:23:52

  • [IEEE 2018 Innovations in Intelligent Systems and Applications (INISTA) - Thessaloniki (2018.7.3-2018.7.5)] 2018 Innovations in Intelligent Systems and Applications (INISTA) - Piezologist: A Novel Wearable Piezoelectric-based Cardiorespiratory Monitoring System

    摘要: In this paper, the design, prototyping and software development of a novel wearable cardiorespiratory parameters monitoring sensor and software applications illustrated. Piezologist is an unobtrusive chest worn device. It comprises a patch-type sensor and a mobile application. The sensor utilizes piezoelectric material as the cardiorespiratory signal sensing component and MetaWearC board as the signal acquisition unit. The board also comes with Bluetooth Low Energy (BLE) support which is utilized for the raw signal transmission. The novelty aspect of the system rests on the fact that not only using a single cheap piezoelectric sheet common cardiorespiratory parameters (such as heart rate, respiration rate, and cycles) were obtained similar to previous studies but ECG waveform and blood pressure data were also extracted successfully using the same sensor. In addition, sensor packaging design and prototyping and their effect on the acquired signal strength on one hand and the package size (volume and weight) on the other hand were studied and reported. For performance validation purpose, the developed cardiorespiratory monitoring system results were validated against two commercial sensor devices namely 3-lead ECG sensor from eHealth sensor kit and Zephyr belt-type BioHarness sensor, and the results were reported herein. The validation process outcomes confirmed that the cardiorespiratory signals extracted using Piezologist conform with a heartbeat, respiratory cycle and ECG waveform obtained using the commercial sensors. Furthermore, a usability study was conducted to compare the user experience offered by Piezologist for measuring cardiorespiratory parameters against the commercially available sensors. The study highlighted the potential that Piezologist will take over the commercial available belt-type, watch-type and 3-lead ECG sensors.

    关键词: biomedical signal processing,heart rate extraction,wearable sensors,Sensors,Vital signs,ECG waveform,Home healthcare,cardiorespiratory,Heartbeats,mobile healthcare,Respiration rate

    更新于2025-09-23 15:22:29

  • The Role of Exercise-Induced Arousal and Exposure to Blue-Enriched Lighting on Vigilance

    摘要: It is currently assumed that exposure to an artificial blue-enriched light enhances human alertness and task performance, but recent research has suggested that behavioral effects are influenced by the basal state of arousal. Here, we tested whether the effect of blue-enriched lighting on vigilance performance depends on participants’ arousal level. Twenty-four participants completed four sessions (blue-enriched vs. dim light × low vs. high arousal) at 10 pm on four consecutive days, following a repeated-measures design. Participants’ arousal was manipulated parametrically through the execution of a cycling task at two intensities (low vs. moderate), and was checked by monitoring their heart rate. On each session, distal and proximal skin temperatures were recorded as a neuroergonomic index of vigilance, while participants performed a 20-min psychomotor vigilance task (PVT) under either blue-enriched light or dim light conditions. The Positive and Negative Affect Schedule (PANAS), Karolinska Sleepiness Scale (KSS), and Borg Rating of Perceived Exertion Scale (RPE) were used to measure subjective psychological state. The results showed that the exercise-induced manipulation of arousal produced robust alerting effects in most measures, while the lighting manipulation only attenuated subjective sleepiness and enhanced positive affect, but it did not influence behavior or physiology. Acute exposure to a blue-enriched light was practically ineffective when the arousal level was over baseline. The present research favored the use of acute physical exercise over acute exposure to blue-enriched lighting in order to boost humans’ levels of alertness when necessary, as in work settings where maintaining optimal attention is difficult (shift work, night-work, vigilance tasks) and necessary to prevent human error and accidents.

    关键词: circadian,light,attention,heart rate,temperature,ergonomics,alertness,physical activity

    更新于2025-09-23 15:22:29

  • Heart rate estimation from photoplethysmography signal for wearable health monitoring devices

    摘要: Wearable wrist type health monitoring devices use photoplethysmography (PPG) signal to estimate heart rate (HR). The HR estimation from these devices becomes difficult due to the existence of strong motion artifacts (MA) in PPG signal thereby leading to inaccurate HR estimation. The objective is to develop a novel de-noising algorithm that reduces the MA present in PPG signal, resulting in an accurate HR estimation. A novel de-noising technique using the hierarchical structure of cascade and parallel combinations of two different pairs of adaptive filters which reduces MA from the PPG signal and improves HR estimation is proposed. The first pair combines normalized least mean squares (NLMS) and recursive least squares (RLS) adaptive filters and the second pair combines recursive least squares (RLS) and least mean squares (LMS) adaptive filters. The de-noised signals obtained from the first and second pairs are combined to form a single de-noised PPG signal by means of convex combination. The HR of the de-noised PPG signal is estimated in the frequency domain using a Fast Fourier transform (FFT). Performance of the proposed technique is evaluated using a dataset of 12 individuals performing running activity in Treadmill. It resulted in an average absolute error of 0.92 beats per minute (BPM), standard deviation of the absolute error of 1.17 beats per minute (BPM), average relative error of 0.72 and Pearson correlation coefficient of 0.9973.

    关键词: Photoplethysmography,Convex combination,Heart rate estimation,Motion artifact,Wearable devices,Combination of adaptive filters

    更新于2025-09-23 15:22:29

  • [IEEE 2018 IEEE 20th International Workshop on Multimedia Signal Processing (MMSP) - Vancouver, BC (2018.8.29-2018.8.31)] 2018 IEEE 20th International Workshop on Multimedia Signal Processing (MMSP) - An Adaptive Bandpass Filter Based on Temporal Spectrogram Analysis for Photoplethysmography Imaging

    摘要: Photoplethysmography Imaging (PPGI) in the sense of remote vital sign measurement via camera has attracted high interest in recent years. The non-contact measurement principle allows the use in many health monitoring applications, like monitoring of newborns. Beyond that, there are interesting areas of application in the multimedia sector, such as measuring the reaction to multimedia content or heart rate based liveness detection for multimedia security. The derived signal of a PPGI algorithm is often referred as blood volume pulse signal (BVP). The signal corresponds to the optical signal of blood volume changes in the upper skin layers. Most current approaches use peak detection in frequency spectrum to estimate heart rate from BVP signals. However, we focus on heart rate computation based on beat-to-beat peak detection in time domain. In this paper, we present a method for adaptive bandpass filtering for PPGI based on temporal spectrogram analysis of the BVP signal with a sliding time window. The main goal of this new method is to further improve accuracy of beat-to-beat peak detection in time domain. The approach exploits the analysis of main frequency components of the BVP signal over time, to build a bandpass filter with adaptive cutoff frequencies in order to filter noise and interference. So far, state-of-the-art approaches have usually used fixed cut-off frequencies in the physiologically possible range of heart rate. The novelty of the proposed method lies in its simple but effective solution to reduce the influence of noise and interference in the PPGI signal to improve peak detection for heart rate estimation. We show the improvements applying the adaptive bandpass filter technique to four basic algorithmic approaches of PPGI, namely ICA, Chrominance, POS and 2SR and comparing against current state-of-the-art peak detection approaches. For the evaluation we used a database with videos of 26 subjects in 4 different scenarios, each lasting two minutes.

    关键词: Photoplethysmography Imaging,time frequency analysis,signal processing,user reaction,peak detection,remote heart rate estimation,adaptive bandpass filtering

    更新于2025-09-23 15:22:29

  • [IEEE 2018 IEEE 8th International Conference on Consumer Electronics - Berlin - Berlin (2018.9.2-2018.9.5)] 2018 IEEE 8th International Conference on Consumer Electronics - Berlin (ICCE-Berlin) - Using the Hilbert-Huang transform to increase the robustness of video based remote heart-rate measurement from human faces

    摘要: Measuring the heart rate(HR) in a conventional way, e.g. using an electrocardiogram, leads to several disadvantages for the patient, such as skin irritation or discomfort. For this reason, remote-based measurement techniques have become more and more popular in recent years. Most of the methods that have been presented use recordings of human faces. These methods recognize minimal changes, invisible to the human eye, in the color spectrum of a persons face to measure heart activity. As a by-product, it is also possible to determine the breath frequency by this method. However, measuring the HR based on a video of someones face is a challenge, as has been reported. One of the biggest problems is ambient light change during the process. To solve this problem and enhance the robustness of the measurement technique, a new approach is proposed in this paper. By using the empirical mode decomposition of the Hilbert Huang transform and independent component analysis (ICA), it is possible to reduce significantly the effects of changes in ambient light conditions. The proposed combination of these two techniques ensures a much greater robustness to changes in light conditions and therefore greater accuracy and can be used in a realistic application environment.

    关键词: measurement,BSS,heart rate,ICA,photoplethysmography,Hilbert-Huang transform

    更新于2025-09-23 15:22:29

  • USING PHOTOPLETHYSMOGRAPHY IMAGING FOR OBJECTIVE CONTACTLESS PAIN ASSESSMENT

    摘要: This work presents an extension to the known Analgesia Nociception Index (ANI), which provides an objective estimation of the current depth of analgesia. An adequate “measure” would facilitate so-called balanced anesthesia. Generally, ANI is computed using heart rate variability or rather beat-to-beat intervals based on an electrocardiogram (ECG). There are clinical situations where no ECG monitoring is available or required, but only photoplethysmography (PPG), e.g., in some cases in postoperative care or pain therapy. In addition, a combination of PPG and ECG for obtaining beat-to-beat intervals may lead to increased robustness and reliability for dealing with artifacts. This work therefore investigates the computation of ANI using standard PPG. In addition, new methods and opportunities are presented using contactless PPG imaging (PPGI). PPGI?enables contactless PPG recordings for deriving beat-to-beat intervals as well as analysis of local perfusion and wounds.

    关键词: PPG,nociception,image based PPG,anesthesiology,ECG,pain,analgesia,heart rate variability,PPGI

    更新于2025-09-23 15:21:01