修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

2 条数据
?? 中文(中国)
  • Pulse Oximetry Screening for Detection of Critical Congenital Heart Defects: Why to Bother?

    摘要: Congenital heart defects (CHD) are the commonest form of congenital malformations affecting 6-8 infants per 1,000 live births. Although congenital heart disease remains an important cause of death in infancy, not all forms of major congenital heart disease will be evident at birth or in the early neonatal period. The current screening tools for detection of CHD are: fetal anomaly screening ultrasound and routine examination of newborn prior to discharge from the hospital. Both of these screening tools have a low detection rate and the studies report that up a third of infants with moderate to severe CHD may be discharged home undiagnosed. Critical congenital heart defects (CCHD) are the most serious form of CHD and defined as conditions requiring surgery or intervention within the first 28 days after birth or result in death. The incidence of CCHD is 2-3 per 1,000 live births. Infants with a CCHD are at risk of sudden deterioration following closure of the ductus arteriosus and can result in cardiovascular collapse, acidosis and death. Early diagnosis of such babies would improve survival, as well as reducing the morbidity associated with circulatory collapse prior to recognition of a problem and administration of appropriate treatment. The infants with CCHD remain well while in-utero because of the fetal circulation. However, majority of infants with CCHD are likely to have some degree of hypoxaemia soon after birth. The infants with moderate or severe hypoxia can be detected clinically, but hypoxia in infants with CCHD is often mild soon after birth making it difficult to detect clinically. Interestingly this can be detected by a very simple test – pulse oximetry. Pulse oximetry is a well-established, simple, visible, fast, accurate and non-invasive method of detecting hypoxaemia. This can objectively quantify the degree of hypoxaemia in asymptomatic infants. Pulse oximetry screening has been well-studied in over 230,000 infants enrolled in many well designed research studies and randomised controlled trials. In 2012, a systematic review and meta-analysis published reported that pulse oximetry screening has a high specificity, moderate sensitivity and a low false-positive rate. This meta-analysis identified 13 studies, of over quarter of a million babies, investigating the use of pulse oximetry screening in detection of CCHDs. The overall sensitivity for pulse oximetry screening was 76.5%, the specificity 99.9% and false positive rate 0.14%. This review concluded that pulse oximetry meets criteria for universal screening for detection of CCHDs6. The addition of pulse oximetry screening to exiting screening tools may increase detection rates for CCHD to over 90%. Other studies have established its cost-effectiveness, acceptability to parents and staff and feasibility of implementing screening outside the research context. In addition, the detection of non-critical CHDs and significant non-cardiac conditions such as respiratory problems or early-onset sepsis is reported as an additional benefit of pulse oximetry screening if performed early. These clinically important conditions contributed to up to two third of the reported false positive groups which reduces the clinically non-significant false positivity to half. In 2011, the United States Health and Human Services recommended adding pulse oximetry screening to the uniform newborn panel and since then pulse oximetry screening is being established as a national US government policy. In recent years, pulse oximetry screening has been recommended by several European countries including Switzerland, Ireland and Poland. The UK national Screening Committee (UK NSC) has recently completed a pilot study on feasibility and implications of pulse oximetry screening. However, it is noteworthy to understand that not all CCHDs are likely to be detected on pulse oximetry screening. In summary, pulse oximetry screening is feasible, cost-effective, and acceptable to staff and parents. It qualifies the criteria for universal screening programme for detection of CCHD, and recently has been recommended by many countries to include in their national screening programme. Adding pulse oximetry screening as an adjunct to the existing screening tools can help in detecting up to 90% CCHDs. However, parents and health care professionals need to aware that not infants with CCHD can be detected with pulse oximetry screening and this test has its own limitations.

    关键词: Screening,Critical congenital heart defects,Hypoxaemia,Pulse oximetry,CCHD

    更新于2025-09-10 09:29:36

  • Solar powered oxygen systems in remote health centers in Papua New Guinea: a large scale implementation effectiveness trial

    摘要: Background Pneumonia is the largest cause of child deaths in Papua New Guinea (PNG), and hypoxaemia is the major complication causing death in childhood pneumonia, and hypoxaemia is a major factor in deaths from many other common conditions, including bronchiolitis, asthma, sepsis, malaria, trauma, perinatal problems, and obstetric emergencies. A reliable source of oxygen therapy can reduce mortality from pneumonia by up to 35%. However, in low and middle income countries throughout the world, improved oxygen systems have not been implemented at large scale in remote, difficult to access health care settings, and oxygen is often unavailable at smaller rural hospitals or district health centers which serve as the first point of referral for childhood illnesses. These hospitals are hampered by lack of reliable power, staff training and other basic services. Methods We report the methodology of a large implementation effectiveness trial involving sustainable and renewable oxygen and power systems in 36 health facilities in remote rural areas of PNG. The methodology is a before–and after evaluation involving continuous quality improvement, and a health systems approach. We describe this model of implementation as the considerations and steps involved have wider implications in health systems in other countries. Results The implementation steps include: defining the criteria for where such an intervention is appropriate, assessment of power supplies and power requirements, the optimal design of a solar power system, specifications for oxygen concentrators and other oxygen equipment that will function in remote environments, installation logistics in remote settings, the role of oxygen analyzers in monitoring oxygen concentrator performance, the engineering capacity required to sustain a program at scale, clinical guidelines and training on oxygen equipment and the treatment of children with severe respiratory infection and other critical illnesses, program costs, and measurement of processes and outcomes to support continuous quality improvement. Conclusions This study will evaluate the feasibility and sustainability issues in improving oxygen systems and providing reliable power on a large scale in remote rural settings in PNG, and the impact of this on child mortality from pneumonia over 3 years post–intervention. Taking a continuous quality improvement approach can be transformational for remote health services.

    关键词: Pneumonia,Papua New Guinea,oxygen therapy,hypoxaemia,solar power,remote health centers

    更新于2025-09-04 15:30:14