修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

2 条数据
?? 中文(中国)
  • Evaluating the Laser Output of the Micropulse P3 Laser Delivery Device Following Repeated Use

    摘要: Repeated use of the Micropulse P3 (MP3) probe during micropulse transscleral cyclophotocoagulation is associated with an increase in laser output over time. The purpose of this study was to examine the laser efficacy of the MP3 probe following repeated use. This was an observational study carried out using Cyclo G6 Glaucoma Laser System with 6 MP3 laser delivery probes. Each probe was fired for 100 seconds, every 10 minutes until the probe was deactivated. The laser output was measured using a laser power meter. Maximum observed laser power output was also noted. All probes were deactivated after 90 minutes (9 cycles) of use. Mean laser output of all 6 probes was determined, and results suggested an increase in output with time. When examining the differences in total laser output for each cycle, no significant differences were observed for the first 4 cycles, but not for the remaining 5 cycles, wherein the increased laser outputs were found to be significantly different from baseline (cycle 1). Findings suggest a possible increase in laser output with repeated use, especially after 4 cycles, and clinicians need to be cautious if they intend to use the probes repeatedly.

    关键词: laser delivery,micropulse transscleral cyclophotocoagulation,glaucoma

    更新于2025-09-12 10:27:22

  • Outcomes of Micropulse Transscleral Cyclophotocoagulation in Uncontrolled Glaucoma Patients

    摘要: This study aimed at evaluating the intermediate-term efficacy and safety of micropulse transscleral cyclophotocoagulation (MP-TSCPC) in cases of uncontrolled glaucoma. Patients with moderate to advanced glaucoma and uncontrolled intraocular pressure (IOP) despite maximally tolerable antiglaucoma medications were selected to undergo MP-TSCPC using the MP3 handpiece with the Iridex Cyclo G6 (IRIDEX Laser Systems). Follow-up examinations took place on a regular basis until 15 months postoperatively. Seventy-five eyes of 69 patients (53.6% male patients) were included. Mean age was 55.5 ± 22.9 years. Primary open-angle glaucoma was the most common diagnosis. Corrected distance visual acuity at baseline ranged between 0 and 2.1 logMAR. Mean prelaser IOP was 26.0 ± 7.91 mm Hg. This was reduced significantly to 13.8 ± 5.6 mm Hg (44.0% reduction, P < 0.001) at week 1, and to 18.0 ± 7.7, 18.4 ± 7.1, 16.7 ± 6.2, 15.1 ± 4.1, 15.7 ± 5.32, and 14.8 ± 5.50 mm Hg at months 1, 3, 6, 9, 12, and 15, respectively. The mean number of antiglaucoma drops decreased significantly up to 12 months of follow-up (P = 0.008) and that of oral acetazolamide tablets decreased significantly up to 15 months (P < 0.001). The success rate decreased progressively with time, reaching 81.4% at 6 months and 73.3% at 1 year. No major postoperative complications were encountered, and no eye lost vision completely. MP-TSCPC is an efficient noninvasive glaucoma treatment that achieves sustained IOP reduction and reduced need for ocular antihypertensive medications for up to 15 months. The optimal laser parameters to achieve the best success rate with the least side effects still need to be determined.

    关键词: intraocular pressure,micropulse transscleral cyclophotocoagulation,glaucoma

    更新于2025-09-11 14:15:04