  • [IEEE 2018 24rd International Workshop on Thermal Investigations of ICs and Systems (THERMINIC) - Stockholm, Sweden (2018.9.26-2018.9.28)] 2018 24rd International Workshop on Thermal Investigations of ICs and Systems (THERMINIC) - Structural analysis and modelling of packaged light emitting devices by thermal transient measurements at multiple boundaries

    摘要: The paper presents a comprehensive methodology for modeling the electrical, optical, and thermal domains of high-power LEDs, focusing on the XPE2 type from Cree. It introduces optimization algorithms (OPT1 and OPT2) to extract parameters such as series resistance (RS), ideality factor (m), and saturation current (I0) from forward voltage (VF) measurements. A quadratic model for radiant voltage (Vrad) is developed to describe the optical output, and thermal modeling is addressed through structure functions derived from transient thermal measurements. The approach enables accurate prediction of LED performance across varying currents and temperatures, with applications in thermal management and design optimization.

    关键词: ideality factor,thermal management,structure function,LED modeling,radiant flux,forward voltage,saturation current,series resistance

    更新于2025-09-23 15:23:52

  • [IEEE 2018 VII. Lighting Conference of the Visegrad Countries (Lumen V4) - Trebic, Czech Republic (2018.9.18-2018.9.20)] 2018 VII. Lighting Conference of the Visegrad Countries (Lumen V4) - Novel Method of Total Spectral Radiant Flux Standard Realization

    摘要: Modern metrology of SSL sources requires a modified approach to future realization of reference standards. This is caused by the fact that traditional broad band and omni-directional light sources used are being replaced by high intensity sources with a specific directional light intensity distribution. At the same time the importance of LED lighting quality assurance is increasing as this new type of lighting is currently replacing traditional light sources in many applications. The specifics of an integrating sphere-spectroradiometer measurement system require the calibration with the use of a reference standard with known Spectral Radiant Flux Distribution, Luminous flux as well as the Luminous Intensity Distribution (LID) to compensate for the sphere system non-uniform reflectance properties. This way the accuracy of the sphere system calibration will allow to measure various types of LED products in conformance with the EN 13032-4:2015, LED lamps, modules and luminaires modules, lamps regardless of their spatial distribution properties. This paper will cover basic concepts and details of a novel method of Total Spectral Radiant Flux (TSRF) realization and description of a TSRF standard facility developed for the Russian National Metrology Institute – VNIIOFI, Moscow. The method (and the developed facility) is based on a goniospectroradiometer system traceable to a standard Black Body and allowing the calibration of a light source in terms of TSRF and additionally providing LID data of the source.

    关键词: calibration,measurement,total spectral radiant flux