修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

2 条数据
?? 中文(中国)
  • A fast reconstruction method for three-dimensional shape measurement using dual-frequency grating projection and phase-to-height lookup table

    摘要: Phase-to-height mapping is indispensable part of three-dimensional (3D) shape measurement system based on phase analysis, which guarantees the accuracy of 3D reconstruction. In this paper, a fast 3D shape reconstruction method based on dual-frequency grating projection and phase-to-height lookup table is proposed. In this proposed method, the reference plane is moved with known interval along the measurement depth direction to establish the mapping lookup table between the phase of the high and low frequency projected grating and their corresponding spatial height pixel by pixel respectively. Then, two methods to establish the lookup table with the unwrapped and the wrapped phase have been respectively introduced according to the characteristics of dual-frequency grating. The actual experimental results show that the two methods can effectively extend the measurement range of the current wrapped phase-to-height lookup method, and the reconstruction accuracy is better than the traditional phase-to-height quadratic fitting method. At the same time, the consumed time for 3D shape reconstruction of the tested object by the two methods is compared and analyzed. Finally, combining the high performance parallel computation of GPU, the fast 3D shape reconstruction is realized with the speed of 60fps.

    关键词: Dual-frequency grating,Parallel computing,3D shape measurement,Multi-reference plane,Phase-to-height mapping

    更新于2025-09-23 15:22:29

  • Does the Location of Bruch's Membrane Opening Change Over Time? Longitudinal Analysis Using San Diego Automated Layer Segmentation Algorithm (SALSA)

    摘要: PURPOSE. We determined if the Bruch’s membrane opening (BMO) location changes over time in healthy eyes and eyes with progressing glaucoma, and validated an automated segmentation algorithm for identifying the BMO in Cirrus high-definition coherence tomography (HD-OCT) images. METHODS. We followed 95 eyes (35 progressing glaucoma and 60 healthy) for an average of 3.7 6 1.1 years. A stable group of 50 eyes had repeated tests over a short period. In each B-scan of the stable group, the BMO points were delineated manually and automatically to assess the reproducibility of both segmentation methods. Moreover, the BMO location variation over time was assessed longitudinally on the aligned images in 3D space point by point in x, y, and z directions. RESULTS. Mean visual field mean deviation at baseline of the progressing glaucoma group was (cid:2)7.7 dB. Mixed-effects models revealed small nonsignificant changes in BMO location over time for all directions in healthy eyes (the smallest P value was 0.39) and in the progressing glaucoma eyes (the smallest P value was 0.30). In the stable group, the overall intervisit–intraclass correlation coefficient (ICC) and coefficient of variation (CV) were 98.4% and 2.1%, for the respectively, automated algorithm for the manual segmentation and 98.1% and 1.9%, respectively, CONCLUSIONS. Bruch’s membrane opening location was stable in normal and progressing glaucoma eyes with follow-up between 3 and 4 years indicating that it can be used as reference point in monitoring glaucoma progression. The BMO location estimation with Cirrus HD-OCT using manual and automated segmentation showed excellent reproducibility.

    关键词: BMO location variation,glaucoma,automated segmentation,reference plane

    更新于2025-09-04 15:30:14