修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

2 条数据
?? 中文(中国)
  • Repeatability and reproducibility of retinal nerve fibre layer thickness measurements with the iVue-100 optical coherence tomographer

    摘要: Background: Accurate and repeatable measurements of the retinal nerve fibre layer (RNFL) thickness are important in the diagnosis and management of glaucoma and other disorders. Objective: To assess the repeatability and reproducibility of the iVue-100 optical coherence tomographer (OCT). Methods: The thickness of the RNFL was measured for 50 healthy participants using the iVue-100 OCT. Although both eyes per participant were measured, only right eyes were analysed here. Repeatability and reproducibility of the iVue-100 OCT were assessed using the intraclass correlation coefficient (ICC), coefficient of variation (CoV), paired t-tests and Bland-Altman analysis. Results: Good intra-observer repeatability was obtained as indicated by the ICC of observer 1 (range: 0.941 - 0.976) and observer 2 (range: 0.829 – 0.953) as well by the CoV of observer 1 (range: 0.098 – 0.137) and observer 2 (0.091 – 0.132). In terms of inter-observer reproducibility, significant differences (p< 0.05) in mean measurements between the observers were noted for the average RNFL readings and in the superior and inferior quadrants as assessed with paired t-tests. Even though significant inter-session differences were found for the average RNFL thickness and the superior quadrant (p = 0.003 and p = 0.013, respectively), excellent ICCs were obtained for inter-session reproducibility (range: 0.914 – 0.979). Conclusion: The iVue-100 OCT demonstrated good repeatability and reproducibility for RNFL thickness measurements.

    关键词: Retinal nerve fibre layer thickness,optical coherence tomography,repeatability,iVue-100 OCT,reproducibility

    更新于2025-09-23 15:22:29

  • Influence of uveitis on Bruch’s membrane opening minimum rim width and retinal nerve fibre layer thickness measurements

    摘要: background/aims To assess the impact of papillary leakage and active inflammation on optical coherence tomography (OCT)-based retinal nerve fibre layer thickness (RNFLT) and Bruch’s membrane opening minimum rim width (BMO-MRW) measurements in uveitic eyes with and without secondary glaucoma. Methods Prospective, single-centre analysis of patients with uveitis. All patients included received a fluorescein angiography examination and an OCT scan measuring the BMO-MRW and the RNFLT in three concentric peripapillary ring scans. results Overall, 95 eyes of 56 patients were enrolled. Papillary leakage and active inflammation were present in 39 (41%) and 57 (60%) eyes, respectively. Twenty-one eyes were classified as glaucomatous; 10 of those glaucomatous eyes showed papillary leakage. Both BMO-MRW and RNFLT measurements were significantly increased in eyes with papillary leakage (BMO-MRW: p=0.0001; RNFL: first to third ring (p<0.0001)). Active inflammation led to a significantly thickened RNFLT (first ring: p=0.0026; second ring: p=0.0009; third ring: p=0.0002) while only a trend towards increased values could be observed in the BMO-MRW measurements (p=0.3063). Glaucomatous eyes with papillary leakage demonstrated significantly higher values on both BMO-MRW and RNFLT measurements than glaucomatous eyes without leakage (BMO-MRW: p=0.0159; RNFL: first ring: p=0.0062; second ring: p=0.0037; third ring: p=0.0197). No significant difference could be observed between glaucomatous eyes with leakage and non-glaucomatous eyes without leakage (BMO-MRW: p=0.4132; RNFL: first ring: p=0.5412; second ring: p=0.3208; third ring: p=0.1164). Conclusions The OCT scanning parameters BMO-MRW and RNFLT were significantly influenced by papillary leakage in uveitic eyes with and without glaucoma. RNFLT values were also significantly increased while active inflammation was present. In patients with uveitis, these OCT-based imaging tools should be interpreted with caution, especially in those with papillary leakage or active inflammation.

    关键词: uveitis,optical coherence tomography,retinal nerve fibre layer thickness,Bruch’s membrane opening minimum rim width,glaucoma

    更新于2025-09-04 15:30:14