修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

2 条数据
?? 中文(中国)
  • [IEEE 2019 IEEE 46th Photovoltaic Specialists Conference (PVSC) - Chicago, IL, USA (2019.6.16-2019.6.21)] 2019 IEEE 46th Photovoltaic Specialists Conference (PVSC) - Unravelling Optical and Electrical Degradation of Perovskite Solar Cells and Impact on Perovskite/Silicon Monolithic Tandem Modules

    摘要: The simultaneous measurement of heat and light signals from a scintillating crystal was performed at temperatures of tens of milli-kelvin using a scintillating bolometric detector. The crystal was instrumented with a pair of low-temperature detectors, consisting of a metallic magnetic calorimeter for reading the phonon signals and a light detector based on a Ge light absorber, to simultaneously measure the scintillation light and phonon signals. This article presents the principle and performance, such as the event separation capability, of this simultaneous heat/light measurement system.

    关键词: low-temperature detector,Calcium molybdate,scintillation crystal,neutrinoless double beta decay,metallic magnetic calorimeters

    更新于2025-09-19 17:13:59

  • O12 scintillator

    摘要: The characteristics of a Gd3Al2Ga3O12 crystal scintillator doped with cerium and co-doped with magnesium and titanium have been studied, mainly in view of using it for the Phase II upgrade of the LHCb electromagnetic calorimeter. Samples of the scintillator were irradiated with γ (60Co) to 2 kGy and with 24 GeV protons to 900 kGy. The proton fluence value was ~3·1015 cm?2. It was found that γ-irradiation did not produce any change in the optical transmission of the crystals in the spectral range of the scintillation light, whereas a degradation after the proton irradiation was measurable. For the 1 cm thick sample, a loss of transmission of 3.6% was measured at the wavelength of maximum scintillation (520 nm), and the measured induced absorption coefficient at this wavelength was ~3.6 m?1. The formation of radioisotopes in the crystal at proton irradiation has been analyzed. The formation of isotopes was also simulated with the help of the FLUKA package. The simulation was found to be in a good agreement with experimental results. The results have been used to estimate the expected intensity of parasitic radio-luminescence at high-luminosity operation in a GAGG/W sampling electromagnetic calorimeter.

    关键词: Electromagnetic calorimetry,radiation damage,gadolinium-aluminum-gallium garnet,optical transmission,scintillation crystal

    更新于2025-09-09 09:28:46