- 标题
- 摘要
- 关键词
- 实验方案
- 产品
过滤筛选
- 2018
- 2015
- classification
- Fruit defects
- Jujube
- Principal component analysis
- Hyperspectral imaging
- Xanthomonas oryzae
- multispectral and multimodal microscopy
- spectroscopic imaging
- plant cell diseases
- rice
- Optoelectronic Information Science and Engineering
- Applied Physics
- Measurement and Control Technology and Instruments
- Brno University of Technology
- University of Sciences, Technique and Technology Bamako
- Mohammed V University in Rabat
- Southern Taiwan University of Science and Technology
- Institut National Polytechnique Felix Houphou?t-Boigny Yamoussoukro
-
[IEEE IGARSS 2018 - 2018 IEEE International Geoscience and Remote Sensing Symposium - Valencia, Spain (2018.7.22-2018.7.27)] IGARSS 2018 - 2018 IEEE International Geoscience and Remote Sensing Symposium - Multi-Attribute Super-Tensor Model for Remote Sensing Image Classification with High Spatial Resolution
摘要: With the development of remote sensors, it is much easier to acquire large amount of remote sensing images (RSIs) with very high spatial resolution, which has made the spatial characteristics play an important role in classification task. Many work of spatial-spectral classification have been done and achieved good results, especially superpixel-based methods. However, these methods didn’t take each superpixel as an entirety, which had ignored the relationship between spatial and spectral signature. It is well known that RSI can be treated as a third-order data cube, thus it can also be represented by a third-order tensor. This paper proposed a Multi-Attribute Superpixel Tensor (MAST) model to address the aforementioned problem. Experiments conducted on two real RSIs and compared with several well-known methods demonstrate the effectiveness of the proposed model.
关键词: remote sensing images,superpixel,spatial-spectral classification,EMAP,tensor
更新于2025-09-23 15:21:21
-
A Prediction-Based Spatial-Spectral Adaptive Hyperspectral Compressive Sensing Algorithm
摘要: In order to improve the performance of storage and transmission of massive hyperspectral data, a prediction-based spatial-spectral adaptive hyperspectral compressive sensing (PSSAHCS) algorithm is proposed. Firstly, the spatial block size of hyperspectral images is adaptively obtained according to the spatial self-correlation coefficient. Secondly, a k-means clustering algorithm is used to group the hyperspectral images. Thirdly, we use a local means and local standard deviations (LMLSD) algorithm to find the optimal image in the group as the key band, and the non-key bands in the group can be smoothed by linear prediction. Fourthly, the random Gaussian measurement matrix is used as the sampling matrix, and the discrete cosine transform (DCT) matrix serves as the sparse basis. Finally, the stagewise orthogonal matching pursuit (StOMP) is used to reconstruct the hyperspectral images. The experimental results show that the proposed PSSAHCS algorithm can achieve better evaluation results—the subjective evaluation, the peak signal-to-noise ratio, and the spatial autocorrelation coefficient in the spatial domain, and spectral curve comparison and correlation between spectra-reconstructed performance in the spectral domain—than those of single spectral compression sensing (SSCS), block hyperspectral compressive sensing (BHCS), and adaptive grouping distributed compressive sensing (AGDCS). PSSAHCS can not only compress and reconstruct hyperspectral images effectively, but also has strong denoise performance.
关键词: interspectral prediction,compressive sensing,spatial-spectral adaptation,hyperspectral images
更新于2025-09-23 15:21:21
-
[IEEE IGARSS 2018 - 2018 IEEE International Geoscience and Remote Sensing Symposium - Valencia, Spain (2018.7.22-2018.7.27)] IGARSS 2018 - 2018 IEEE International Geoscience and Remote Sensing Symposium - The Effects of VIIRS Spectral Response Differences between Suomi NPP and NOAA-20 for the Thermal Emissive Bands
摘要: The NOAA-20 satellite was successfully launched on November 18, 2017 into an afternoon orbit with local equator crossing time ~1:30pm, in the same orbital plane as that of the Suomi National Polar-orbiting Partnership (NPP) but with a time separation of half an orbit or ~50 minutes. The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard NOAA-20 will become the primary operational imager succeeding the VIIRS onboard Suomi NPP which has been in-orbit for more than six years. Although the VIIRS onboard Suomi NPP and NOAA-20 have identical design, there are small differences in the relative spectral response (RSR) in most bands. Previous studies have shown that minor differences in RSR can lead to a number of effects at detector level, such as striping. This study investigates the VIIRS RSR differences between Suomi NPP and NOAA-20 for the Thermal Emissive Bands (TEB) including M12-M16. The Line-By-Line radiative transfer model (LBLRTM) is used at very high spectral resolution for convolving with the RSR of VIIRS on both satellites. The impact of RSR difference between Suomi NPP and NOAA-20 are evaluated for radiometric biases and potential striping in TEB. This study will contribute to the measurement consistency for the long term observations in the thermal infrared bands, and ensure the quality of the data produced by VIIRS, such as sea surface temperature (SST), fire and other retrievals.
关键词: Spectral Response Function,LBLRTM,VIIRS,Thermal Emissive Band
更新于2025-09-23 15:21:21
-
Adaption of an array spectroradiometer for total ozone column retrieval using direct solar irradiance measurements in the UV spectral range
摘要: A compact array spectroradiometer that enables precise and robust measurements of solar UV spectral direct irradiance is presented. We show that this instrument can retrieve total ozone column (TOC) accurately. The internal stray light, which is often the limiting factor for measurements in the UV spectral range and increases the uncertainty for TOC analysis, is physically reduced so that no other stray-light reduction methods, such as mathematical corrections, are necessary. The instrument has been extensively characterised at the Physikalisch-Technische Bundesanstalt (PTB) in Germany. During an international total ozone measurement intercomparison at the Iza?a Atmospheric Observatory in Tenerife, the high-quality applicability of the instrument was verified with measurements of the direct solar irradiance and subsequent TOC evaluations based on the spectral data measured between 12 and 30 September 2016. The results showed deviations of the TOC of less than 1.5 % from most other instruments in most situations and not exceeding 3 % from established TOC measurement systems such as Dobson or Brewer.
关键词: stray-light reduction,direct solar irradiance measurements,array spectroradiometer,total ozone column,UV spectral range
更新于2025-09-23 15:21:21
-
Effect of Open Soil Surface Patterns on Soil Detectability Based on Optical Remote Sensing Data
摘要: Arable soils are subjected to the altering influence of agricultural and natural processes determining surface feedback patterns therefore affecting their ability to reflect light. However, remote soil mapping and monitoring usually ignore information on surface state at the time of data acquisition. Conducted research demonstrates the contribution of surface feedback dynamics to soil reflectance and its relationship with soil properties. Analysis of variance showed that the destruction surface patterns accounts for 71% of spectral variation. The effect of surface smoothing on the relationships between soil reflectance and its properties varies. In the case of organic matter and medium and coarse sand particles, correlation decreases with the removement of surface structure. For particles of fine sand and coarse silt, grinding changes spectral areas of high correlation. Partial least squares regression models also demonstrated variations in complexity, R2cv and RMSEPcv. Field dynamics of surface feedback patterns of arable soils causes 22–46% of soil spectral variations depending on the growing season and soil type. The directions and areas of spectral changes seem to be soil-specific. Therefore, surface feedback patterns should be considered when modelling soil properties on the basis of optical remote sensing data to ensure reliable and reproducible results.
关键词: digital soil mapping,remote sensing,spectral reflectance,surface feedback
更新于2025-09-23 15:21:21
-
Quantification of Vortex Generation Due to Non-Equilibrium Electrokinetics at the Micro/Nanochannel Interface: Spectral Analysis
摘要: We report on our investigation of a low Reynolds number non-equilibrium electrokinetic ?ow in a micro/nanochannel platform. Non-equilibrium electrokinetic phenomena include so-called concentration polarization in a moderate electric ?eld and vortex formation in a high electric ?eld. We conducted a spectral analysis of non-equilibrium electrokinetic vortices at a micro/nanochannel interface. We found that periodic vortices are formed while the frequency varies with the applied voltages and solution concentrations. At a frequency as high as 60 Hz, vortex generation was obtained with the strongest electric ?eld and the lowest concentration. The power spectra show increasing frequency with increasing voltage or decreasing concentration. We expect that our spectral analysis results will be useful for micromixer developers in the micromachine research ?eld.
关键词: spectral analysis,concentration polarization,micromixer,Vortex generation,electrokinetics,micro/nanochannel
更新于2025-09-23 15:21:21
-
A Novel Recovery Method of Soft X-ray Spectrum Unfolding Based on Compressive Sensing
摘要: In the experiment of inertial con?nement fusion, soft X-ray spectrum unfolding can provide important information to optimize the design of the laser and target. As the laser beams increase, there are limited locations for installing detection channels to obtain measurements, and the soft X-ray spectrum can be dif?cult to recover. In this paper, a novel recovery method of soft X-ray spectrum unfolding based on compressive sensing is proposed, in which (1) the spectrum recovery is formulated as a problem of accurate signal recovery from very few measurements (i.e., compressive sensing), and (2) the proper basis atoms are selected adaptively over a Legendre orthogonal basis dictionary with a large size and Lasso regression in the sense of (cid:96)1 norm, which enables the spectrum to be accurately recovered with little measured data from the limited detection channels. Finally, the presented approach is validated with experimental data. The results show that it can still achieve comparable accuracy from only 8 spectrometer detection channels as it has previously done from 14 detection channels. This means that the presented approach is capable of recovering spectrum from the data of limited detection channels, and it can be used to save more space for other detectors.
关键词: spectral measurement,spectrum unfolding,sparse representation,soft X-ray spectrometer,compressive sensing,lasso regression
更新于2025-09-23 15:21:21
-
New clinical ultrahigh-resolution SD-OCT using A-scan matching algorithm
摘要: Purpose A new clinical ultrahigh-resolution spectral domain optical coherence tomography (UHR-SD-OCT) system using an original averaging technique named BA-scan matching algorithm^ was developed. The aim of this study was to determine whether our new UHR-SD-OCT system can obtain clearer sectional images of the retina than conventional standard resolution SD-OCT systems (SR-SD-OCT). Methods We recorded horizontal B-scan images of 42 normal eyes using our new UHR-SD-OCT device (Bi-μ, Kowa) and a conventional SR-SD-OCT (Spectralis, Heidelberg). To evaluate the clarity of the interdigitation zone (IZ) subjectively, the integrity of IZ was divided into three types by two raters. To evaluate the clarity of the IZ objectively, a peak height score (PHS) was calculated at five different points of the macula using the longitudinal reflectivity profile. Results The mean (± SD) of the subjective visibility score of the IZ in the UHR-SD-OCT images was 2.64 ± 0.54 which was significantly higher than the 2.46 ± 0.46 in the SR-SD-OCT images (P = 0.02). The PHS was also significantly higher for the UHR-SD-OCT than for the SR-SD-OCT images at all five locations (all P < 0.01). Conclusion The results indicate that the newly developed clinical UHR-SD-OCT instrument using the A-scan matching algorithm can obtain clearer images of the IZ, and they suggest that this device should be clinically useful in detecting finer structural abnormalities of the outer retina.
关键词: Spectral domain,Ultrahigh-resolution,Optical coherence tomography (OCT),Interdigitation zone,Retina
更新于2025-09-23 15:21:21
-
[Lecture Notes in Computer Science] Intelligence Science and Big Data Engineering Volume 11266 (8th International Conference, IScIDE 2018, Lanzhou, China, August 18–19, 2018, Revised Selected Papers) || An Improved Spectral Clustering Algorithm Based on Dynamic Tissue-Like Membrane System
摘要: With vast amount of data generated, it is becoming a main aspect to mine useful information from such data. Clustering research is an important task of data mining. Traditional clustering algorithms such as K-means algorithm are too old to propose high-dimensional data, so an ef?cient clustering algorithm, spectral clustering is generated. In recent years, more and more scholars has been ?rmly committing to studying spectral clustering algorithm for its solid theoretical foundation and excellent clustering results. In this paper we propose an improved spectral clustering algorithm based on Dynamic Tissue-like P System abbreviated as ISC-DTP. ISC-DTP algorithm takes use of the advantages of maximal parallelism in tissue-like membrane system. Experiment is conducted on an arti?cial data set and four UCI data sets. And we compare the ISC-DTP algorithm with original spectral clustering algorithm and K-means algorithm. The experiments demonstrate the effectiveness and robustness of the proposed algorithm.
关键词: Spectral clustering algorithm,Tissue-like membrane system,Data mining,ISC-DTP algorithm
更新于2025-09-23 15:21:21
-
[IEEE 2018 VII. Lighting Conference of the Visegrad Countries (Lumen V4) - Trebic, Czech Republic (2018.9.18-2018.9.20)] 2018 VII. Lighting Conference of the Visegrad Countries (Lumen V4) - The Uncertainty of Measurement of Spectroradiometric System with Double Monochromator
摘要: This article has task to inform a reader about uncertainties of measurement of spectroradiometric systems with double monochromator. Uncertainty of measurement is very important for all photometric measurements and calculations. Spectroradiometric system’s uncertainty is dependent on wavelength and is difficult to estimate uncertainty of measurement for photometric parameters calculated from measured spectrum. In the first part of this article there is theory necessary for understanding uncertainty analyses and description of construction of spectroradiometric system with double monochromator. In the second part there is practical uncertainty analysis of double monochromator in light laboratory and its results.
关键词: spectral irradiance,correlated color temperature,double monochromator,color rendering index,Uncertainty of measurement
更新于2025-09-23 15:21:21