修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

4 条数据
?? 中文(中国)
  • Water-sensitive ratiometric fluorescent probes and application to test strip for rapid and reversible detection of water

    摘要: Naphthalimide-decorated fluorinated acetamides 1 and 2 were developed as solvent-sensitive dual emissive fluorescence probes. Particularly, 1 exhibited dual emission with a large Stokes shift for water, DMF, and DMSO solvents over other various organic solvents. The dual emission might be due to the increase of intramolecular charge transfer (ICT) of the naphthalimide moiety through the association of the difluorinated acetamide group with the solvent molecules. The 1 can give rise to a ratiometric change in the dual emission and a visual fluorescent color change depending on the water contents in organic solvents, including ethanol, methanol, acetonitrile and DMF solvents. Moreover, the 1-impregnated paper strips showed a rapid and easy-to-visualize fluorescent color change enabling water detection in organic solvents. These simple-to-use paper strips were also found to be reusable over 20 times.

    关键词: Naphthalimide,Ratiometric fluorescence probe,Reusable test strip,Intramolecular charge transfer (ICT),Water detection

    更新于2025-11-19 16:46:39

  • Gold nanoparticles of different shape for bicolor lateral flow test

    摘要: Spherical gold nanoparticles are the most commonly used marker in lateral flow assays. However, the widespread practice of using identical coloration for the test and control zones of test strips can lead to erroneous interpretations of the assay’s results. We propose an immunochromatographic test strip with lines of different colors. For this purpose, gold nanoparticles of different shapes were used, namely blue nanoflowers in the test zone and red gold nanospheres in the control zone. A detailed synthesis procedure for nanoparticles and their conjugates is considered and design parameters for optimal results are described. For the first time, nanoparticles of different shapes have been combined in the test strip with indirect labeling of specific antibodies (via their interaction with labeled secondary antibodies). Using the T-2 toxin (T2T) as an example, an instrumental detection limit of 30 pg/mL and a working range 0.06-0.9 ng/mL were achieved in an analysis of water-organic corn extracts.

    关键词: gold nanoparticles,Immunochromatography,test strip,mycotoxin,indirect labeling,gold nanoflowers

    更新于2025-09-23 15:23:52

  • Construction of a Novel Fluorescent Probe for On-site Measuring Hydrogen Sulfide Levels in Food Samples

    摘要: Hydrogen sulfide (H2S) has been involved in many foodstuffs and beverages. On-site measuring the H2S level in food samples was beneficial to the concerns about food safety and food quality. Herein, we rationally constructed a novel fluorescent probe to track the H2S levels in various food samples. The optical experiments indicated that the probe displayed highly selective and sensitive response to H2S. In addition, the probe can function well in a wide pH value condition, providing a reliable platform to sense H2S. The practical application demonstrated that the probe was applied for tracking H2S levels in banana, grape, and vinegar for the first time. Importantly, by fabricating test strips, the probe was first served to monitor the released H2S in raw meat without relying on elaborate instrumentation. Thus, the probe could be employed as a simple tool to measure the H2S levels in various food samples, as well as to monitor the fresh-like quality of raw meat under on-site conditions.

    关键词: Fluorescent probe,On-site measurement,Hydrogen sulfide,Food sample,Test strip

    更新于2025-09-23 15:23:52

  • Development and application of fluorescence sensor and test strip based on molecularly imprinted quantum dots for the selective and sensitive detection of propanil in fish and seawater samples

    摘要: Molecularly imprinted quantum dots (MIP-QDs) were successfully synthesized via reversed-phase microemulsion and used as the specific recognition element and signal probe of a fluorescence sensor or test strip to achieve the highly sensitive detection of fish and seawater samples. In addition, the limits of detection (LODs) for fish and seawater were 0.42 μg/kg and 0.38 μg/L, respectively. The fluorescence test strip developed on the basis of the MIP-QDs also displayed satisfactory recoveries of 90.1%–111.1%, and the LOD for propanil in the seawater sample was 0.6 μg/L. The proposed fluorescence sensor and test strip were successfully used in propanil determination in environment and aquatic products.

    关键词: Quantum dot,Molecularly imprinted,Propanil,Fluorescence,Test strip

    更新于2025-09-16 10:30:52