修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

1 条数据
?? 中文(中国)
  • Comparison between broadband and monochromatic photopic negative response in full-field electroretinogram in controls and subjects with primary open-angle glaucoma

    摘要: Purpose A prospective, cross-sectional, case–control study was conducted to investigate the role of broadband and monochromatic photopic negative response (PhNR) of the full-field flash electroretinogram (ERG) in the evaluation of ganglion cell damage in primary open-angle glaucoma (POAG) subjects. Methods Subjects with POAG and age-matched normal subjects were recruited from the outpatient department of a tertiary eye care center in South India. A total of 25 patients with POAG and 50 age-matched normal subjects were recruited. ERG was recorded using broadband (3.5 cd.s/m2 white stimulus on 10 cd/m2 white background) and monochromatic (3.5 cd.s/m2 red stimulus on 10 cd/m2 blue background and 1 cd.s/m2 blue stimulus on 10 cd/m2 yellow background) stimuli. Results The reduction in PhNR amplitude in POAG compared to normal individuals was higher in red-on-blue PhNR [26.37 μV; p < 0.001, confidence interval (CI) 19.34 to 33.4] as compared to broadband stimuli (16.41 μV; p < 0.001, CI 8.68 to 24.13), and blue on yellow (21.96 μV; p < 0.001, CI 10.12 to 33.8). Red-on-blue PhNR amplitudes correlated better with mean deviation (MD; r = -0.66, p < 0.05), pattern standard deviation (PSD; r = -0.4, p = 0.04), visual field index (VFI; r = -0.58, p < 0.05), and retinal nerve fiber layer thickness (r = -0.67, p < 0.05) in comparison with broadband and monochromatic blue-on-yellow PhNR. Receiver operating characteristic curve revealed largest area under the curve (0.89) in red-on-blue PhNR compared to broadband (0.76) and blue on yellow (0.74). The sensitivity and specificity was also higher in red-on-blue PhNR (72% and 80%, respectively) as compared to the other stimuli (sensitivity and specificity of broadband 0.68 and 0.7, blue on yellow 0.64 and 0.7, respectively). Conclusion Correlation of PhNR with Humphrey visual field parameters and retinal nerve fiber layer thickness showed that red-on-blue PhNR can be a useful additional tool for clinical assessment of retinal ganglion cell dysfunction in glaucoma patients. Red-on-blue PhNR was more sensitive as compared to white-on-white and blue-on-yellow PhNR in identifying ganglion cell dysfunction and correlates well with other structural and functional tests for glaucoma such as MD, PSD, VFI, and RNFL thickness.

    关键词: Primary open-angle glaucoma,Photopic negative response,Broadband ERG,Full-field electroretinogram,Monochromatic ERG

    更新于2025-09-23 15:23:52