Assessment of focused multivector ultraviolet disinfection with shadowless delivery using 5-point multisided sampling of patient care equipment without manual-chemical disinfection
摘要: The aim of this study was to evaluate the performance of a focused multivector ultraviolet (FMUV) system employing shadowless delivery with a 90-second disinfection cycle for patient care equipment inside and outside the operating room (OR) suite without manual-chemical disinfection. A 5-point multisided sampling protocol was utilized to measure the microbial burden on objects inside and outside the OR environment in a 3-phase nonrandomized observational study. Surface sampling was performed pre- and postdisinfection in between cases (IBCs) to assess the performance of manual-chemical disinfection. FMUV system performance was separately assessed pre- and postdisinfection before the first case and IBCs. Additionally, visibly clean high-touch objects were sampled outside the OR, and the microbial burden reductions after FMUV disinfection were quantified without manual-chemical disinfection. Manual-chemical disinfection reduced the active microbial burden on sampled objects IBCs by 52.8%-90.9% (P < .05). FMUV reduced the active microbial burden by 92%-97.7% (P < .0001) before the first case and IBCs combined, and 96.3%-99.6% (P < .0001) on objects outside the OR without chemical disinfection. Five-point multisided sampling proved effective for assessing disinfection performance on all exterior sides of equipment. FMUV produced significant overall reductions of the microbial burden on patient care equipment in all study phases and independent of manual cleaning and chemical disinfection.
关键词: Disinfectants,Surface sampling techniques,Manual cleaning,Environmental disinfection,Ultraviolet germicidal irradiation,Infection prevention
更新于2025-09-10 09:29:36
-
Environmental disinfection with photocatalyst as an adjunctive measure to control transmission of methicillin-resistant Staphylococcus aureus: a prospective cohort study in a high-incidence setting
摘要: Background: Environmental disinfection with continuously antimicrobial surfaces could offer superior control of surface bioburden. We sought to decide the efficacy of photocatalyst antimicrobial coating in reducing methicillin-resistant Staphylococcus aureus (MRSA) acquisition in high incidence setting. Methods: We performed prospective cohort study involving patients hospitalized in medical intensive care unit. A titanium dioxide-based photocatalyst was coated on high touch surfaces and walls. Five months of pre-intervention data were compared with five months of post-intervention data. The incidence rates of multidrug-resistant organism acquisition and the rates of hospital-acquired blood stream infection, pneumonia, urinary tract infection, and Clostridium difficile–associated diseases were compared using Cox proportional hazards regression analysis. Results: In total, 621 patients were included. There was significant decrease in MRSA acquisition rate after photocatalyst coating (hazard ratio, 0.37; 95% confidence interval, 0.14–0.99; p = 0.04). However, clinical identification of vancomycin-resistant Enterococcus spp. and multidrug-resistant Acinetobacter baumannii did not decrease significantly. The hazard of contracting hospital-acquired pneumonia during the intervention period compared to baseline period was 0.46 (95% confidence interval, 0.23–0.94; p = 0.03). Conclusions: In conclusion, MRSA rate was significantly reduced after photocatalyst coating. We provide evidence that photocatalyst disinfection can be an adjunctive measure to control MRSA acquisition in high-incidence settings. Trial registration: ISRCTN Registry (ISRCTN31972004). Registered retrospectively on November 19, 2018.
关键词: Environmental disinfection,Hospital-acquired infection,MRSA,Photocatalyst