修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

4 条数据
?? 中文(中国)
  • Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study

    摘要: Objective: To investigate the efficacy of motion-correction algorithm (MCA) in improving coronary artery image quality and measurement accuracy using an anthropomorphic dynamic heart phantom and 256-detector row computed tomography (CT) scanner. Materials and Methods: An anthropomorphic dynamic heart phantom was scanned under a static condition and under heart rate (HR) simulation of 50–120 beats per minute (bpm), and the obtained images were reconstructed using conventional algorithm (CA) and MCA. We compared the subjective image quality of coronary arteries using a four-point scale (1, excellent; 2, good; 3, fair; 4, poor) and measurement accuracy using measurement errors of the minimal luminal diameter (MLD) and minimal luminal area (MLA). Results: Compared with CA, MCA significantly improved the subjective image quality at HRs of 110 bpm (1.3 ± 0.3 vs. 1.9 ± 0.8, p = 0.003) and 120 bpm (1.7 ± 0.7 vs. 2.3 ± 0.6, p = 0.006). The measurement error of MLD significantly decreased on using MCA at 110 bpm (11.7 ± 5.9% vs. 18.4 ± 9.4%, p = 0.013) and 120 bpm (10.0 ± 7.3% vs. 25.0 ± 16.5%, p = 0.013). The measurement error of the MLA was also reduced using MCA at 110 bpm (19.2 ± 28.1% vs. 26.4 ± 21.6%, p = 0.028) and 120 bpm (17.9 ± 17.7% vs. 34.8 ± 19.6%, p = 0.018). Conclusion: Motion-correction algorithm can improve the coronary artery image quality and measurement accuracy at a high HR using an anthropomorphic dynamic heart phantom and 256-detector row CT scanner.

    关键词: Heart rate,Tomography,X-ray computed,Coronary vessels,Phantoms,Imaging,Motion-correction algorithm

    更新于2025-09-23 15:23:52

  • Intra-slice motion correction of intravascular OCT images using deep features

    摘要: Intra-slice motion correction is an important step for analyzing volume variations and pathological formations from intravascular imaging. Optical Coherence Tomography (OCT) has been recently introduced for intravascular imaging and assessment of coronary artery disease. 2D cross-sectional OCT images of coronary arteries play a crucial role to characterize the internal structure of the tissues. Adjacent images could be compounded, however they might not fully match due to motion, which is a major hurdle for analyzing longitudinally each tissue in 3D. The aim of this study is to develop a robust tissue matching based motion correction approach from a sequence of 2D intracoronary OCT images. Our motion correction technique is based on the correlation between deep features obtained from Convolutional Neural Network (CNN) for each frame of a sequence. The optimal transformation of each frame is obtained by maximizing the similarity between the tissues of reference and moving frames. The results show a good alignment of the tissues after applying CNN features and determining the transformation parameters.

    关键词: Deep Features,Optical Coherence Tomography (OCT),Coronary Artery,Motion Correction,Tissue Characterization

    更新于2025-09-23 15:21:01

  • Patient motion correction for dynamic cardiac PET: Current status and challenges

    摘要: For dynamic cardiac PET of quantifying myocardial blood flow (MBF), patient motion is a major factor that affects the ROI definition and absolute quantification accuracy. In a recent study, an 82rubidium (82Rb)-dynamic-tailored motion-correction framework has been proposed to address the voluntary body motion for all the dynamic frames, including both early and late phases. This approach brings us one step closer to the practical and full motion correction for dynamic cardiac PET studies. In this editorial, we discussed the current status and limitations of motion-correction methods for dynamic cardiac PET, including the recent publication at JNC, and also pointed out the remaining challenges for future developments.

    关键词: 82rubidium,dynamic cardiac PET,myocardial blood flow,motion-correction framework,patient motion correction

    更新于2025-09-09 09:28:46

  • Dual-phase whole-heart imaging using image navigation in congenital heart disease

    摘要: Background: Dual-phase 3-dimensional whole-heart acquisition allows simultaneous imaging during systole and diastole. Respiratory navigator gating and tracking of the diaphragm is used with limited accuracy. Prolonged scan time is common, and navigation often fails in patients with erratic breathing. Image-navigation (iNAV) tracks movement of the heart itself and is feasible in single phase whole heart imaging. To evaluate its diagnostic ability in congenital heart disease, we sought to apply iNAV to dual-phase sequencing. Methods: Healthy volunteers and patients with congenital heart disease underwent dual-phase imaging using the conventional diaphragmatic-navigation (dNAV) and iNAV. Acquisition time was recorded and image quality assessed. Sharpness and length of the right coronary (RCA), left anterior descending (LAD), and circumflex (LCx) arteries were measured in both cardiac phases for both approaches. Qualitative and quantitative analyses were performed in a blinded and randomized fashion. Results: In volunteers, there was no significant difference in vessel sharpness between approaches (p > 0.05). In patients, analysis showed equal vessel sharpness for LAD and RCA (p > 0.05). LCx sharpness was greater with dNAV (p < 0.05). Visualized length with iNAV was 0.5 ± 0.4 cm greater than that with dNAV for LCx in diastole (p < 0.05), 1.0 ± 0.3 cm greater than dNAV for LAD in diastole (p < 0.05), and 0.8 ± 0.7 cm greater than dNAV for RCA in systole (p < 0.05). Qualitative scores were similar between modalities (p = 0.71). Mean iNAV scan time was 5:18 ± 2:12 min shorter than mean dNAV scan time in volunteers (p = 0.0001) and 3:16 ± 1:12 min shorter in patients (p = 0.0001). Conclusions: Image quality of iNAV and dNAV was similar with better distal vessel visualization with iNAV. iNAV acquisition time was significantly shorter. Complete cardiac diagnosis was achieved. Shortened acquisition time will improve clinical applicability and patient comfort.

    关键词: Respiratory motion correction,Dual phase imaging,Congenital heart disease,Steady-state free precession MRI

    更新于2025-09-04 15:30:14