- 标题
- 摘要
- 关键词
- 实验方案
- 产品
-
Thermostimulated THz Radiation Emission of GaAs at Surface Plasmon-Phonon Polariton Frequencies
摘要: The THz radiation reflection, absorption and emission spectra of conductive n-GaAs/air surface are considered. The influence of thermostimulated surface plasmon-phonon (SPP) polariton oscillations on THz radiation reflection, absorption and emission of high conductivity GaAs polished plates with electron density n = 7·1017 cm–3 and 4·1018 cm–3 and thickness of 350 μm is studied experimentally. The frequencies of thermostimulated transverse and longitudinal optical phonons and SPP oscillations, which characterize a heated lattice state, were determined. It is found that the heated highly doped interface layer (GaAs/air) emits the THz radiation at selected frequencies of SPP oscillations in the (7 – 8) THz and (10 – 15) THz ranges. It is shown that thermal heating of the GaAs/air interface enhances the absorption of the incident THz radiation. The huge decrease of the incident radiation reflectivity at the SPP frequencies with an increase of GaAs temperature is observed experimentally.
关键词: surface plasmon-phonon polaritons,black-body radiation,GaAs,thermostimulated THz radiation emission
更新于2025-09-19 17:15:36
-
Application of portable near-infrared spectrometer to Heliotron J plasma diagnostics
摘要: A simple near-infrared (NIR) spectrometer with a wavelength range of 898–2130 nm has recently been applied to diagnose Heliotron J plasmas. It adopts a symmetrical crossed Czerny–Turner mount equipped with a thermoelectrically cooled 512 channel InGaAs linear sensor. Reciprocal linear dispersion was deduced to 96.37 nm/mm at the center of the detector. External ?lters can be inserted into the path of the collection optics to reject second-order spectra, as needed. Absolute intensity calibration was performed together with a visible spectrometer using a tungsten halogen lamp, and the effect of the transmittance fringe in the visible region of the applied long-pass ?lter on the NIR calibration was investigated. The intended application of the NIR spectrometer includes extending the wavelength region of a spectral monitor to less contaminated regions for Heliotron J plasma studies. In preliminary measurements, we observed the Paschen series for the hydrogen pellet injection plasma and two atomic helium lines, i.e., 2S-2P singlet and triplet lines, in helium gas puf?ng experiments. A continuum spectrum in this regime that is attributable to black-body radiation from hot spots on the plasma-facing components was identi?ed. In addition, this may also be used to monitor background radiation in the YAG-Thomson scattering signals near 1064 nm.
关键词: near-infrared spectrometer,YAG-Thomson scattering,plasma diagnostics,helium lines,black-body radiation,Paschen series,Heliotron J
更新于2025-09-10 09:29:36