修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

13 条数据
?? 中文(中国)
  • [IEEE 2018 2nd International Conference on Engineering Innovation (ICEI) - Bangkok (2018.7.5-2018.7.6)] 2018 2nd International Conference on Engineering Innovation (ICEI) - Diabetic retinopathy fundus image classification using discrete wavelet transform

    摘要: Diabetes is an incurable disease which erodes away body slowly, this disease in becoming common and becoming a cause of social distress. The only solution to this problem is early detection of disease and take precautionary measure to keep its effects to minimum. Since it affects various parts of body, the affected organ also includes eye which is very sensitive to any kind of distress. Diabetic Retinopathy effects of diabetes on eye retina, which includes rupturing of retina blood vessels and abnormal growth of blood vessels in retina, which ultimately causes blindness. Diabetic Retinopathy can be identified by examining the retinoscopy images. In this paper, retinoscopy images were processed using wavelet transform. Wavelet coefficients extracted from the images were obtained to identify Diabetic Retinopathy. KNN and SVM were used to classify the retinoscopy images. This papers have shown remarkable improvement as compared to previous studies, with KNN at 98.16 % accuracy and SVM at 97.85 % accuracy.

    关键词: sensitivity,specificity,Discrete Wavelet Transform (DWT),accuracy,KNN,Diabetic Retinopathy (DR),histogram equalization,SVM

    更新于2025-09-10 09:29:36

  • Assessment of haemoglobin measurement by several methods - blood gas analyser, capillary and venous HemoCue <sup>?</sup> , non-invasive spectrophotometry and laboratory assay - in term and preterm infants

    摘要: A laboratory haematology analyser is the gold standard for measuring haemoglobin concentration but has disadvantages, especially in neonates. This study compared alternative blood-sparing and non-invasive methods of haemoglobin concentration measurement with the gold standard. Haemoglobin concentrations were measured using a laboratory haematology analyser (reference method), blood gas analyser, HemoCue using venous and capillary blood samples and a newly developed non-invasive sensor for neonates < 3 kg. A total of 63 measurements were performed. Body weight (2190 (1820–2520 [967–4450]) g) and haemoglobin concentration (12.3 (10.6–15.2 [8.2–20.5]) g.dl-1) varied widely. Bias/limits of agreement between the alternative methods and reference method were -0.1/-1.2 to 1.0 g.dl-1 (blood gas analyser), -0.4/-1.8 to 1.1 g.dl-1 (HemoCue, venous blood), 0.7/-1.9 to 3.2 g.dl-1 (HemoCue, capillary blood) and -1.2/-4.3 to 2 g.dl-1 (non-invasive haemoglobin measurement). Perfusion index, body weight and fetal haemoglobin concentration did not affect the accuracy of the alternative measurement methods, and these were successfully applied in term and preterm infants. However, the accuracies of non-invasive haemoglobin measurement and HemoCue of capillary blood especially lacked sufficient agreement with that of the reference method to recommend these methods for clinical decision making.

    关键词: fetal haemoglobin: oxygen,coagulation,anaemia,sensitivity and specificity,monitored anaesthesia care: requirements

    更新于2025-09-09 09:28:46

  • A novel near-infrared “turn-on” fluorescent probe for selective detection of Fe3+ and its application in vitro imaging

    摘要: A novel near-infrared fluorescent probe RHCC was devised and synthesized. It exhibits high specificity to Fe3+ compared to other metals in aqueous solutions. The detection limit of RHCC was 1.2 × 10-7 M and the complexation stability constant was 5.807 × 104 M-1. The binding ratio of RHCC and Fe3+ was 1:1 which was measured through MS, FTIR and Job’s plot. The energy gap between HOMO and LUMO of RHCC was 3.22 eV, while RHCC-Fe3+ complex was 0.95 eV. This result means the binding of probe RHCC and Fe3+ lowers the RHCC-Fe3+ complex’s energy gap and makes it more stable. What’s more, in living cells and zebrafishes studies, probe RHCC was no significant cytotoxic effect, indicating it could monitor Fe3+ in biological system.

    关键词: near-infrared probe,vitro imaging,“turn-on”,high specificity

    更新于2025-09-09 09:28:46