修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

oe1(光电查) - 科学论文

425 条数据
?? 中文(中国)
  • Novel near-infrared fluorescent liquid crystal: Bodipy bearing multiple alkyl chains with columnar mesophase

    摘要: By the typical Knoevenagel condensation of Bodipy with aldehyde derivatives, two novel Bodipy derivatives 3 and 6 with symmetric three and six alkyl chains were designed and prepared. The Bodipy derivative 3 with three alkyl chains showed no mesophase but the Bodipy derivative 6 with six alkyl chains possessed the orderly hexagonal columnar mesophase at room temperature. Both samples 3 and 6 exhibited the near-infrared fluorescence with high fluorescence quantum yields and larger Stokes shifts than their Bodipy precursors. Sample 6 was the first near-infrared fluorescent columnar liquid crystal with Bodipy core. This research presented a good strategy on constructing the near-infrared columnar Bodipy liquid crystal.

    关键词: Near-infrared,Bodipy,columnar,mesophase,fluorescence

    更新于2025-09-23 15:22:29

  • Hydrolysis kinetics of silane coupling agents studied by near-infrared spectroscopy plus partial least squares model

    摘要: A method of Fourier transform near-infrared (FT-NIR) spectroscopy combined with partial least squares (PLS) model was successfully applied to investigate the hydrolysis kinetics of four kinds of silane coupling agents (phenyltriethoxysilane, vinyltriethoxysilane, 3-mercaptopropyltriethoxysilane, 3-chloropropyltriethoxysilane) in an acid-catalyzed EtOH system. The fast scanning speed and high sensitivity of the FT-NIR spectroscopy, and the powerful data processing ability of the PLS, enabled the method to quantitatively and accurately catch the fast changing H2O concentration during the hydrolysis processes without delay, realizing the study of the fast-paced hydrolysis reactions of the silane coupling agents. The results showed that electrophilic substitution occurred in the hydrolysis reactions, which followed second-order reactions and greatly depend on the catalyst concentration and reaction temperature. The hydrolysis rate constants, activation energy, and Arrhenius Frequency factors were gained. In conclusion, the FT-NIR PLS model is a powerful tool for hydrolysis kinetics researching of the silane coupling agents.

    关键词: partial least squares,Hydrolysis kinetic,silane coupling agent,near infrared

    更新于2025-09-23 15:22:29

  • Electrochromism in Electropolymerized Films of Pyrene-Triphenylamine Derivatives

    摘要: Two star-shaped multi-triphenylamine derivatives 1 and 2 were prepared, where 2 has an additional phenyl unit between a pyrene core and surrounding triphenylamine units. The oxidative electropolymerization of 1 and 2 occurred smoothly to give thin films of polymers P1 and P2. The electrochemistry and spectroelectrochemistry of P1 and P2 were examined, showing two-step absorption spectral changes in the near-infrared region. The electrochromic properties, including contrast ratio, response time, and cyclic stability of P1 and P2 were investigated and compared. Thin film of P2 displays slightly better electrochromic performance than P1, with a contrast ratio of 45% at 1475 nm being achieved.

    关键词: triphenylamine,near-infrared,electrochemistry,electrochromism,electropolymerization

    更新于2025-09-23 15:22:29

  • A Nondestructive Real-Time Detection Method of Total Viable Count in Pork by Hyperspectral Imaging Technique

    摘要: A nondestructive method was developed for assessing total viable count (TVC) in pork during refrigerated storage by using hyperspectral imaging technique in this study. The hyperspectral images in the visible/near-infrared (VIS/NIR) region of 400–1100 nm were acquired for fifty pork samples, and their VIS/NIR diffuse reflectance spectra were extracted from the images. The reference values of TVC in pork samples were determined by classical microbiological plating method. Both partial least square regression (PLSR) model and support vector machine regression model (SVR) of TVC were built for comparative analysis to achieve better results. Different transformation methods and filtering methods were applied to improve the models. The results show that both the optimized PLSR model and SVR model can predict the TVC very well, while the SVR model based on second derivation was better, which achieved with RP (correlation coefficient of prediction set) = 0.94 and SEP (standard error of prediction set) = 0.4570 log CFU/g in the prediction set. An image processing algorithm was then developed to transfer the prediction model to every pixel of the image of the entire sample; the visualizing map of TVC would be displayed in real-time during the detection process due to the simplicity of the model. The results demonstrated that hyperspectral imaging is a potential reliable approach for non-destructive and real-time prediction of TVC in pork.

    关键词: visible/near-infrared,total viable count,pork,hyperspectral imaging

    更新于2025-09-23 15:22:29

  • Engineering Tunable Broadband Near-Infrared Emission in Transparent Rare-Earth Doped Nanocrystals-in-Glass Composites via a Bottom-Up Strategy

    摘要: Applications of trivalent rare earth (RE3+)-doped light sources in solid-state laser technology, optical communications, biolabeling, and solar energy management have stimulated a growing demand for broadband emission with flexible tunability and high efficiency. Codoping is a conventional strategy for manipulating the photoluminescence of active RE3+ ions. However, energy transfer between sensitizers and activators usually induces nonradiative migration depletion that brings detrimental luminescent quenching. Here, a transparent framework is employed to assemble ordered RE3+-doped emitters to extend the emission spectral range by extracting photons from a variety of RE3+ ions with sequential energy gradient. To block migration-mediated depletion between different RE3+ ions, a nanoscopic heterogeneous architecture is constructed to spatially confine the RE3+ clusters via a 'nanocrystals-in-glass composite' (NGC) structure. This bottom-up strategy endows the obtained RE3+-doped NGC with high emission intensity (nearly one order of magnitude enhancement) and broadband near-infrared emission from 1300 to 1600 nm, which covers nearly the whole low-loss optical communication window. Most crucially, NGC is a versatile approach to design tunable broadband emission for the potential applications in high-performance photonic devices, which also provides new opportunities for engineering multifunctional materials by integration and manipulation of diverse functional building units in a nanoscopic region.

    关键词: luminescence,rare earth doping,broadband emission,nanocrystals-in-glass composite,near-infrared emission

    更新于2025-09-23 15:22:29

  • Automatic calibration of an arbitrarily-set near-infrared camera for patient surface respiratory monitoring

    摘要: Purpose: A patient’s respiratory monitoring is one of the key techniques in radiotherapy for a moving target. Generally, such monitoring systems are permanently set to a fixed geometry during the installation. This study aims to enable a temporary setup of such a monitoring system by developing a fast method to automatically calibrate the geometrical position by a quick measurement of calibration markers. Methods: One calibration marker was placed on the isocenter and the other six markers were placed at positions 5-cm apart from the isocenter to the left, right, anterior, posterior, superior, and inferior directions. A near-infrared (NIR) camera (NIC) (Kinect v2 (Microsoft Corp.)) was arbitrarily set with ten different angles around the calibration phantom with a fixed tilting-down angle at approximately 45° in a linear accelerator treatment vault. The 3D coordinates in the camera (Cam) coordinate system (CS) (x and y are the horizontal and vertical coordinates of the image, respectively, and z is a coordinate along the NIR time-of-flight) were taken for one minute with 30 frames per second. The data corresponding to the measurement times of 1, 3, 10, 30, and 60 s were created to mimic various measurement times. These data were used to calculate the initial matrix elements, which included six parameters of the pitching, yawing, and rolling angles; horizontal 2D translation in the treatment room; and the source-to-axis distance of NIC, for a conversion from the Cam CS to the treatment-room CS for which the origin was defined at the isocenter (Iso coordinate). The six parameters were then optimized to minimize the displacements of the calculated marker coordinates from the actual positions in the Iso CS. The 3D positional accuracy and angular accuracy of the conversion were evaluated. The random error of the Iso coordinates was analyzed through a relation with the angle of each measurement setup. Results: Three angles of NIC and relative translation vectors were successfully calculated from the measurement data of the calibration markers. The achieved spatial and angular accuracies were 0.02 mm and 1.6°, respectively, after the optimization. Among the mimicked measurement times investigated in this study, both spatial and angular accuracies had no dependence on the measurement time. The average random error of a static marker was 0.46 mm after the optimization. Conclusion: We developed an automatic method to calibrate the 3D patient surface monitoring system. The procedure developed in this study enabled a quick calibration of NIC, which can be easily repeated multiple times for a frequent and quick setup of the monitoring system.

    关键词: near-infrared camera,respiratory monitoring,calibration

    更新于2025-09-23 15:22:29

  • A New Generation of NIR-II Probes: Lanthanide-Based Nanocrystals for Bioimaging and Biosensing

    摘要: Fluorescence-based imaging in the second near infrared window (NIR-II, 1000–1700 nm) is extensively used in both fundamental scientific research and clinical practice, owing to its advances of high sensitivity and high spatiotemporal resolution with increasing tissue penetration depths. Among several NIR-II fluorophores, recent accomplishments in biocompatible lanthanide-based luminescent nanomaterials have aroused great interest of researchers. This progress report summarizes recent progress in controlled synthesis of lanthanide-based NIR-II nanomaterials and their state-of-the-art in NIR-II biomedical imaging and biosensing applications. In addition, challenges and opportunities for this kind of novel NIR-II nanoprobes are also discussed.

    关键词: lanthanides,bioimaging,NIR-II,near infrared imaging,fluorescence,nanoparticles

    更新于2025-09-23 15:22:29

  • Predicting Mechanical Strength of In-Use Firefighter Protective Clothing Using Near-Infrared Spectroscopy

    摘要: The exact lifespan of in-use firefighter protective clothing is difficult to predict due to the large variations in use between individual garments. Furthermore, testing methods used to evaluate new protective clothing are destructive in nature and could not be applied to in-use garments. Various non-destructive techniques have been proposed for the evaluation of in-use clothing, each possessing its own advantages and disadvantages. The ability of near-infrared spectroscopy to predict the tensile strength of thermally aged fabrics used in protective clothing for wildland firefighters and other workers is investigated here. Fabrics were exposed to heat fluxes from 10 kW/m2 to 40 kW/m2 for various durations using the cone calorimeter, after which the tensile strength of the fabrics was measured. Temperatures measured during the exposures and results of thermal gravimetric analysis tests were used to interpret changes in tensile strength. Multivariate linear regression was used to develop correlations between the tensile strength and the reflectance values measured between 1500 nm and 2500 nm for new and thermally aged fabrics. It was found that models based on reflectance measurements made at as few as three wavelengths could be used to estimate the tensile strength of the thermally aged specimens.

    关键词: Thermal ageing,Near-infrared spectroscopy,Firefighter,Durability,Non-destructive testing,Protective clothing

    更新于2025-09-23 15:22:29

  • Investigation on Near-Infrared Quantitative Detection based on Heteromorphic Sample Pool

    摘要: To enhance the detection precision of samples with scattering characteristics by near infrared spectroscopy (NIRS), this study developed a heteromorphic sample pool and established the related 2D light intensity acquisition system, which can simultaneously acquire multi-path exit light adsorption and scattering information of the samples under test. The Intralipid-20% phantom solutions in 34 samples with different concentrations were detected, while one-dimensional (1D) exit light intensity distributions and two-dimensional (2D) exit light intensity distributions on the surface of the samples were analyzed and modeled using partial least squares. In contrast with the prediction results based on the modeling method of 1D exit light intensity distribution, the modeling method of 2D exit light intensity distribution exhibits more favorable results; specifically, correlation coefficient enhanced by 2.48%, while root mean square error reduced by 6.89%. The experimental results demonstrate that using heteromorphic sample pool can effectively achieve NIRS-based detection precision and speed of chemical components in the solutions with scattering characteristics, which can provide important references for high-throughput and high-precision detection of turbid media in analytical chemistry.

    关键词: two-dimensional (2D) light intensity distribution,heteromorphic sample pool,near-infrared spectrum

    更新于2025-09-23 15:22:29

  • Three-photon near-infrared quantum cutting in β-NaGdF4:Yb3+

    摘要: Three-photon near-infrared quantum cutting of Gd3+ to Yb3+ was observed in b-NaGdF4:Yb3+ for the first time. The consistency between theoretical predictions by applying rate equations in the quantum cutting model and experimental results obtained from fluorescence spectra successfully confirmed the occurrence of three-photon near-infrared quantum cutting. The strong interaction between Yb3+ ions is a key factor affecting energy transfer. Maximum energy transfer efficiency and the quantum efficiency can reach 98.2% and 296.5%, respectively. High-efficiency three-photon near-infrared quantum cutting has an admirably promising application prospect in improving the photoelectric conversion efficiency of c-Si solar cells.

    关键词: Near-infrared quantum cutting,b-NaGdF4,Three-photon

    更新于2025-09-23 15:22:29