Methods of improving spatial resolution for IR spectroscopy in atmospheric-pressure plasma systems
摘要: High-temperature, atmospheric pressure plasma systems operated in molecular gases present complex diagnostic challenges. Infrared spectroscopy has been used to make measurements of the absorbance spectrum of complex molecular gas mixtures and thereby calculate the concentrations and species temperatures in these systems. For atmospheric-pressure systems, high spatial gradients arise and high spatial-resolution measurements are thus desirable. Some systems have achieved increased spatial resolution by reducing the beam diameter. However, this increase in spatial resolution comes at the expense of the optical throughput. Here we propose modifying a commercial Fourier Transform, Infrared spectrometer system with a set of simple optical elements. This design allows for scannable, high spatial resolution absorbance spectrum measurements of a complex molecular gas mix. We analyze the signal-to-noise ratio for this design and compare it with the diameter reduction method. For sufficiently low plasma radiation levels, this design improves the signal-to-noise ratio relative to reducing the beam diameter size while transmitting nearly all of the beam power. However, whether this design can achieve the desired sub-mm spatial resolution depends on the radiating area of the infrared light source in the spectrometer.
关键词: Fourier Transform Infrared spectrometer,IR spectroscopy,spatial resolution,atmospheric-pressure plasma systems,signal-to-noise ratio
更新于2025-09-04 15:30:14
-
Collection efficiency of <i>α</i>-pinene secondary organic aerosol particles explored via light-scattering single-particle aerosol mass spectrometry
摘要: We investigated the collection ef?ciency and effective ionization ef?ciency for secondary organic aerosol (SOA) particles made from α-pinene + O3 using the single-particle capabilities of the aerosol mass spectrometer (AMS). The mean count-based collection ef?ciency (CEp) for SOA across these experiments is 0.30 (±0.04 SD), ranging from 0.25 to 0.40. The mean mass-based collection ef?ciency (CEm) is 0.49 (±0.07 SD). This sub-unit collection ef?ciency and delayed vaporization is attributable to particle bounce in the vaporization region. Using the coupled optical and chemical detection of the light-scattering single-particle (LSSP) module of the AMS, we provide clear evidence that “delayed vaporization” is somewhat of a misnomer for these particles: SOA particles measured as a part of the AMS mass distribution do not vaporize at a slow rate; rather, they ?ash-vaporize, albeit often not on the initial impact with the vaporizer but instead upon a subsequent impact with a hot surface in the vaporization region. We also ?nd that the effective ionization ef?ciency (de?ned as ions per particle, IPP) decreases with delayed arrival time. CEp is not a function of particle size (for the mobility diameter range investigated, 170–460 nm), but we did see a decrease in CEp with thermodenuder temperature, implying that oxidation state and/or volatility can affect CEp for SOA. By measuring the mean ions per particle produced for monodisperse particles as a function of signal delay time, we can separately determine CEp and CEm and thus more accurately measure the relative ionization ef?ciency (compared to ammonium nitrate) of different particle types.
关键词: aerosol mass spectrometer,collection efficiency,α-pinene,ionization efficiency,delayed vaporization,particle bounce,secondary organic aerosol
更新于2025-09-04 15:30:14
-
Accurate mobile remote sensing of XCO<sub>2</sub> and XCH<sub>4</sub> latitudinal transects from aboard a research vessel
摘要: A portable Fourier transform spectrometer (FTS), model EM27/SUN, was deployed onboard the research vessel Polarstern to measure the column-average dry air mole fractions of carbon dioxide (XCO2) and methane (XCH4) by means of direct sunlight absorption spectrometry. We report on technical developments as well as data calibration and reduction measures required to achieve the targeted accuracy of fractions of a percent in retrieved XCO2 and XCH4 while operating the instrument under field conditions onboard the moving platform during a 6-week cruise on the Atlantic from Cape Town (South Africa, 34? S, 18? E; 5 March 2014) to Bremerhaven (Germany, 54? N, 19? E; 14 April 2014). We demonstrate that our solar tracker typically achieved a tracking precision of better than 0.05? toward the center of the sun throughout the ship cruise which facilitates accurate XCO2 and XCH4 retrievals even under harsh ambient wind conditions. We define several quality filters that screen spectra, e.g., when the field of view was partially obstructed by ship structures or when the lines-of-sight crossed the ship exhaust plume. The measurements in clean oceanic air, can be used to characterize a spurious air-mass dependency. After the campaign, deployment of the spectrometer alongside the TCCON (Total Carbon Column Observing Network) instrument at Karlsruhe, Germany, allowed for determining a calibration factor that makes the entire campaign record traceable to World Meteorological Organization (WMO) standards. Comparisons to observations of the GOSAT satellite and concentration fields modeled by the European Centre for Medium-Range Weather Forecasts (ECMWF) Copernicus Atmosphere Monitoring Service (CAMS) demonstrate that the observational setup is well suited to provide validation opportunities above the ocean and along interhemispheric transects.
关键词: solar tracker,EM27/SUN,atmospheric greenhouse gases,XCO2,XCH4,Fourier transform spectrometer,shipborne measurements
更新于2025-09-04 15:30:14
-
A vacuum ultraviolet photoionization time-of-flight mass spectrometer with high sensitivity for study of gas-phase radical reaction in a flow tube
摘要: Photoionization mass spectrometry as a powerful analytical method has been widely utilized and provided valuable insight in the field of gas-phase reactions. Here, a highly sensitive vacuum ultraviolet (VUV) photoionization time-of-flight mass spectrometer combined with a microwave discharge generator and a fast flow tube reactor has been developed to study radical reactions of atmospheric and combustion interests. Two kinds of continuous light sources, the tunable VUV synchrotron radiation at Hefei, China for isomer-specific product detection and a commercial krypton discharge lamp for time-consuming kinetic measurements, are employed as photoionization sources in the apparatus. A multiplexed detection with high sensitivity (the limit of detection ~0.8 ppb) and high mass resolution (M/ΔM ~ 2100) has been approached. As representative examples, the self-reaction of the methyl radical, CH3, and the reaction of the methyl radical with molecular oxygen are studied and multiple species including reactive radicals and isomeric/isobaric products are detected and identified. In addition, some preliminary results related to the reaction kinetics are also presented.
关键词: methyl peroxy radical,kinetics,flow tube,Photoionization mass spectrometer,methyl radical,radical reaction
更新于2025-09-04 15:30:14
-
Polarisation analysis on the LET time-of-flight spectrometer
摘要: We present a design for implementing uniaxial polarisation analysis on the LET cold neutron time-of-?ight spectrometer, installed on the second target station at ISIS. The polarised neutron beam is to be produced by a transmission-based supermirror polariser with the polarising mirrors arranged in a “double-V” formation. This will be followed by a Mezei-type precession coil spin ?ipper, selected for its small spatial requirements, as well as a permanent magnet guide ?eld to transport the beam polarisation to the sample position. The sample area will contain a set of holding ?eld coils, whose purpose is to produce a highly homogenous magnetic ?eld for the wide-angle 3He analyser cell. To facilitate fast cell changes and reduce the risk of cell failure, we intend to separate the cell and cryostat from the vacuum of the sample tank by installing both in a vessel at atmospheric pressure. When the instrument upgrade is complete, the performance of LET is expected to be commensurate with existing and planned polarised cold neutron spectrometers at other sources. Finally, we discuss the implications of performing uniaxial polarisation analysis only, and identify quasi-elastic neutron scattering (QENS) on ionic conducting materials as an interesting area to apply the technique.
关键词: cold neutron,polarisation analysis,LET spectrometer,quasi-elastic neutron scattering,supermirror polariser,Mezei-type precession coil,time-of-?ight,3He analyser cell
更新于2025-09-04 15:30:14
-
On-Line Analysis of Oil-Dissolved Gas in Power Transformers Using Fourier Transform Infrared Spectrometry
摘要: To address the problem of on-line dissolved gas analysis (DGA) of a power transformer, a Fourier transform infrared (FT-IR) spectrometer was used to develop an analysis instrument. Carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), ethane (C2H6), ethylene (C2H4) and acetylene (C2H2) were the analytes for the FT-IR spectrometer while propane (C3H8), propylene (C3H6), propyne (C3H4), n-butane (n-C4H10) and iso-butane (iso-C4H10) were the interferents, which might exist in the dissolved gas but are not currently used as analytes for detecting an internal fault. The instrument parameters and analysis approach are first introduced. Specifically, an absorption spectra reading approach by switching two cone-type gas cells into separate light-paths was presented for reducing the effects of gas in the gaps between gas cells and spectrometers, scanning the background spectrum without clearing the sample cell, and increasing the dynamics. Then, the instrument was tested with a standard gas mixture that was extracted from insulation oil in a power transformer. The testing results show that the detection limit of every analyte component is lower than 0.1 μL/L, and the detection limits of all analytes meet the detection requirements of oil-dissolved gas analysis, which means that the FT-IR spectrometer may be an ideal instrument due to its benefits, such as being maintenance-free and having a high stability.
关键词: power transformer,oil-dissolved gas,gas chromatograph,spectral analysis,Fourier transform infrared spectrometer
更新于2025-09-04 15:30:14
-
High resolution, high signal-to-noise crystal spectrometer for measurements of line shifts in high-density plasmas
摘要: The Orion high-resolution x-ray (OHREX) spectrometer has been a successful tool for measuring the shapes of density-broadened spectral lines produced in short-pulse heated plasmas at the Orion laser facility. We have recently out?tted the instrument with a charge-couple device (CCD) camera, which greatly increased the accuracy with which we can perform line-shift measurements. Because OHREX is located on the outside of the Orion target chamber, no provisions for the shielding of electromagnetic pulses are required. With the CCD, we obtained a higher signal-to-noise ratio than we previously obtained with an image-plate detector. This allowed us to observe structure in the image produced by the diffraction from the two OHREX crystals, which was highly reproducible from shot to shot. This structure will ultimately limit the accuracy of our spectroscopic measurements.
关键词: high-resolution x-ray spectrometer,CCD camera,signal-to-noise ratio,high-density plasmas,line shifts
更新于2025-09-04 15:30:14
-
[IEEE IGARSS 2018 - 2018 IEEE International Geoscience and Remote Sensing Symposium - Valencia (2018.7.22-2018.7.27)] IGARSS 2018 - 2018 IEEE International Geoscience and Remote Sensing Symposium - Remote Sensing Using VNIR/SWIR Dispersive Imaging Spectrometers: Historical Development, Current State-of-the-Art, and Furture Trends
摘要: The development of remote sensing using an imaging spectrometer is traced from its origins to the current highly performing spectral sensors. The advancement of the technology has primarily been driven by novel optical designs and focal plane array development. Current state-of-the-art dispersive sensors, employing innovative grating or prism arrangements, operate at low F-numbers while maintaining a high degree of aberration control. These challenging designs have been implemented in hardware with alignment tolerances on the order of microns. The application of imaging spectrometers to science problems that require highly accurate radiometry necessitates new characterization approaches that combine state-of-the-art radiometric sources and detailed sensor models. Future challenges are to reduce the size, weight, and power requirements while maintaining the performance of current systems.
关键词: VNIR/SWIR,optical designs,remote sensing,imaging spectrometer,focal plane array
更新于2025-09-04 15:30:14
-
[IEEE IGARSS 2018 - 2018 IEEE International Geoscience and Remote Sensing Symposium - Valencia, Spain (2018.7.22-2018.7.27)] IGARSS 2018 - 2018 IEEE International Geoscience and Remote Sensing Symposium - The Use of a Quadcopter-Mounted Hyper-Spectral Spectrometer for Examining Reflectance in Scottish Coastal Waters
摘要: Remote sensing of the marine coastal environment is useful for obtaining information about processes occurring within it. Monitoring has traditionally been carried out in situ, before investment increased in remote techniques such as manned planes and satellites. This paper proposes the use of remotely piloted aircraft systems (RPAS) as an alternative platform, with an aim of increasing the spectral, spatial and temporal resolution of data whilst reducing the associated costs and risks. A custom-built ‘spectro-copter’ system, comprising of an integrated dual field-of-view, miniaturised, hyper-spectral spectrometer aboard a purpose-built quadcopter is presented, developed at the Scottish Association for Marine Science (SAMS), Oban. This has been produced with a view to investigating reflectance from Scottish coastal waters, which can give inferences as to the concentrations of various constituents present [1, 2]. Initial test flights show the ‘spectro-copter’ system is capable of flights of ~20 minutes, sufficient for meaningful data collection, despite late adjustments incurring increased weight and an associated reduction in efficiency. Early results demonstrate that the setup is capable of discerning differences in R at a high spectral resolution. Further work is ongoing in order to assess the capacity for establishing this equipment as a routine technique for the monitoring of coastal harmful algal blooms (HAB), which currently relies upon physical sampling in combination with satellites. HAB events are noted to be increasing in severity and frequency [3, 4], with knock-on health and economic impacts, particularly for the rising aquaculture industry in Scottish coastal waters [5]. Therefore advancement of an alternative, affordable technique would be extremely beneficial.
关键词: spectrometer,Scottish coastal waters,reflectance,remote-sensing,quadcopter,remotely piloted aircraft system,hyper-spectral
更新于2025-09-04 15:30:14
-
A micro-scale plasma spectrometer for space and plasma edge applications (invited)
摘要: A plasma spectrometer design based on advances in lithography and microchip stacking technologies is described. A series of curved plate energy analyzers, with an integrated collimator, is etched into a silicon wafer. Tests of spectrometer elements, the energy analyzer and collimator, were performed with a 5 keV electron beam. The measured collimator transmission and energy selectivity were in good agreement with design targets. A single wafer element could be used as a plasma processing or fusion first wall diagnostic.
关键词: electron beam,microchip stacking,silicon wafer,plasma processing,fusion first wall diagnostic,lithography,plasma spectrometer,collimator,energy analyzer