研究目的
The study aims to improve the photovoltaic and enzymatic-sensing performance by coupling core-shell Au nanorod@TiO2 heterostructure with bioinspired L-DOPA polymer for glucose detection.
研究成果
The PD/AuNR@TiO2 composite exhibits enhanced photovoltaic performance and serves as a versatile PEC biosensing platform. The developed PEC enzymatic biosensor for glucose detection shows high sensitivity, a wide linear range, and good specificity, with potential applications in clinical diagnosis and health care.
研究不足
The study does not explicitly mention limitations, but potential areas for optimization could include further enhancing the photocurrent density and exploring the application of the biosensor in more complex biological samples.
1:Experimental Design and Method Selection:
The study involves the synthesis of AuNR@TiO2 core-shell nanostructure and its coupling with PD for enhanced PEC performance.
2:Sample Selection and Data Sources:
Human blood serum samples were used for glucose analysis.
3:List of Experimental Equipment and Materials:
Includes FTO electrodes, AuNR, TiO2, L-DOPA, GOx, HRP, and other chemicals.
4:Experimental Procedures and Operational Workflow:
Detailed steps for the synthesis of AuNR@TiO2, fabrication of PD/AuNR@TiO2/FTO, and construction of the PEC glucose biosensor.
5:Data Analysis Methods:
Photocurrent responses, IPCE measurements, and glucose concentration analysis.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Transmission electron microscope
FEI Tecnai G2 F20
FEI
Used for TEM and HRTEM characterizations.
-
Scanning electron microscope
FEI Hellos Nanolab 600i
FEI
Used for SEM characterizations.
暂无现货
预约到货通知
-
X-ray diffractometer
Rigaku Rapid IIR
Rigaku
Used for XRD pattern collection.
暂无现货
预约到货通知
-
Dynamic light scattering
Malvern Zetasizer NanoZS
Malvern
Used to measure the size of AuNR.
暂无现货
预约到货通知
-
UV-2450 ultraviolet-visible spectrophotometer
UV-2450
Shimadzu
Used for UV-vis spectrophotometry.
暂无现货
预约到货通知
-
FTO
P003
Zhuhai Kaivo Optoelectronic Technology Co., Ltd.
Used as the working electrode in the experiment.
暂无现货
预约到货通知
-
Electrochemical workstation
ZENNIUM
ZAHNER-elecktrik GmbH & Co. KG
Used for PEC experiments.
暂无现货
预约到货通知
-
PEC setup
CIMPS, PP211
ZAHNER-elecktrik GmbH & Co. KG
Used for PEC measurements.
暂无现货
预约到货通知
-
Light source
WLC02
ZAHNER-elecktrik GmbH & Co. KG
Used as the excitation source for PEC measurements.
暂无现货
预约到货通知
-
Tunable light source
TLS03
ZAHNER-elecktrik GmbH & Co. KG
Used for IPCE measurements.
暂无现货
预约到货通知
-
登录查看剩余8件设备及参数对照表
查看全部