研究目的
To assess if surgical safety can be improved by intraoperative use of intraocular lens (IOL) for cataract phacoemulsification.
研究成果
Intraoperative use of IOL can improve surgical safety for dense cataract phacoemulsification by reducing the risk of PCR, improving BCVA, and reducing endothelial cell loss and central corneal thickness increase.
研究不足
The study was limited to patients with age-related cataracts and nuclear hardness denser than Grade III. The follow-up period was short, and the study was conducted at a single center.
1:Experimental Design and Method Selection:
A randomized controlled clinical trial was conducted to compare the effectiveness of intraoperative intraocular lens use on improving surgical safety for dense cataract phacoemulsification. Patients were randomly assigned into three groups with different surgical settings.
2:Sample Selection and Data Sources:
401 patients diagnosed with age-related cataracts and nuclear hardness denser than Grade III were recruited. Inclusion criteria included a pupil diameter of 7 mm or larger and corneal endothelial cell count greater than 1200/mm
3:List of Experimental Equipment and Materials:
Alcon Infiniti System, MicroTip 0.9 mm ABS phaco tip, ProVisc (1% sodium hyaluronate), foldable IOL (ZCB00, AMO), Anterior Segment Imaging VISANTE OCT 1000, microscope (SP-2000 P, Topcon).
4:9 mm ABS phaco tip, ProVisc (1% sodium hyaluronate), foldable IOL (ZCB00, AMO), Anterior Segment Imaging VISANTE OCT 1000, microscope (SP-2000 P, Topcon). Experimental Procedures and Operational Workflow:
4. Experimental Procedures and Operational Workflow: All surgeries were performed with a standard quick chop technique. The last nuclear quadrant was emulsified by different methods in each group. Postoperative outcomes were evaluated by another ophthalmologist.
5:Data Analysis Methods:
Statistical analysis was performed using SPSS 22.0 for Windows 10.0 software. The one-way ANOVA and LSD post-hoc multiple comparisons were used to evaluate the difference between groups.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Alcon Infiniti System
Alcon
Phacoemulsification machine used for cataract surgery.
-
MicroTip 0.9 mm ABS phaco tip
45°, Kelman
Used for emulsifying the cataract during surgery.
-
ProVisc
1% sodium hyaluronate
Alcon
Used to reform and stabilize the surgical planes and protect the corneal endothelium.
-
foldable IOL
ZCB00
AMO
Intraocular lens used as a scaffold during phacoemulsification.
-
Anterior Segment Imaging VISANTE OCT 1000
Carl Zeiss
Used to measure central corneal thickness.
-
microscope
SP-2000 P
Topcon
Used to measure corneal endothelial cell counts.
-