研究目的
To develop a blind method for color decomposition of histological images that accurately identifies morphological features linked to cancer, overcoming issues related to image intensity variations, spectral signatures, and noise at image acquisition.
研究成果
The Blind Color Decomposition (BCD) method provides more accurate decompositions than methods based on non-negative matrix factorization and independent component analysis, resulting in density maps that allow for accurate identification of morphological features linked to cancer.
研究不足
The method fails if a stain is not present in the image data or if the stain absorption is poor. It applies only to light absorbing stains, not to those that scatter light like DAB.