研究目的
To present a modularized control strategy of DFIG system under unbalanced and harmonic grid voltage, avoiding sequence decomposition and complicated control reference calculation, and to analyze the system's performance under different control targets.
研究成果
The paper concludes that the proposed modularized control strategy effectively avoids negative and harmonic component extraction, simplifies control reference calculation, and eliminates the need for communication between RSC and GSC. However, it also identifies limitations such as electromagnetic torque pulsation, DC-link voltage fluctuations, and third harmonic current production under certain conditions.
研究不足
1) Electromagnetic torque pulsation at 100 and 300 Hz can damage DFIG bearing and gear-box. 2) DC-link voltage fluctuations at 100 and 300 Hz require increased capacitor size for safe operation. 3) Third harmonic current component production under certain control targets may pollute the power grid.