研究目的
Investigating the therapeutic effects of a specific herbal medicine on a particular disease.
研究成果
We have demonstrated an effective method to fabricate high efficiency, low efficiency roll-off hybrid WOLEDs via employing an assistant layer with TTA up-conversion characteristics to reduce the concentration of triplet excitons in EML, which convert triplet excitons into singlet ones to compensate the efficiency loss, resulting in the reduced efficiency roll-off at high luminance. In addition, the device operational stability as the main problem of WOLEDs could be also successfully improved. By properly applying the TTA material in EMLs, the triplet excitons in exciton recombination zone can be transferred to the triplet states of TTA with high efficiency characteristics at high luminance, which will be beneficial for the application of WOLEDs in lighting fields.
研究不足
The technical and application constraints of the experiments, as well as potential areas for optimization.
1:Experimental Design and Method Selection:
Includes the overall experimental design rationale, the theoretical models or algorithms employed, and detailed procedures of the experimental methods.
2:Sample Selection and Data Sources:
Specifies the samples or datasets used in the experiment, including selection criteria and data acquisition methods.
3:List of Experimental Equipment and Materials:
Enumerates the required instruments, devices, and materials, along with their specifications and intended uses.
4:Experimental Procedures and Operational Workflow:
Provides a step-by-step description of the experimental process, covering equipment setup, data collection techniques, and control of variables during the experiment.
5:Data Analysis Methods:
Explains the approach for analyzing experimental data, including statistical techniques and software tools utilized.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Keithley 2400 source meter
2400
Keithley
Recording the electrical characteristics of the encapsulated devices
暂无现货
预约到货通知
-
Shimadzu UV-2600 spectrophotometer
UV-2600
Shimadzu
Measuring the UV/vis absorption
暂无现货
预约到货通知
-
Edinburgh Instruments FLS980 spectro-fluorometer
FLS980
Edinburgh Instruments
Measuring the excitation PL spectra
-
Agilent 8114A pulse generator
8114A
Agilent
Testing the transient EL characteristics
暂无现货
预约到货通知
-
PR650 spectrometer
PR650
Attaining the EL spectra
暂无现货
预约到货通知
-
Quantaurus-Tau fluorescence lifetime measurement system
Quantaurus-Tau
Performing the PL transient decay curves of the films
暂无现货
预约到货通知
-
登录查看剩余4件设备及参数对照表
查看全部