研究目的
Investigating the therapeutic effects of a specific herbal medicine on a particular disease.
研究成果
An in-depth analysis and summary of the results summarized, emphasizing interpretability and forward-looking nature. Based on the results, it further refines the core findings, significance of the research, and suggestions for future studies.
研究不足
The technical and application constraints of the experiments, as well as potential areas for optimization.
1:Experimental Design and Method Selection:
Includes the overall experimental design rationale, the theoretical models or algorithms employed, and detailed procedures of the experimental methods.
2:Sample Selection and Data Sources:
Specifies the samples or datasets used in the experiment, including selection criteria and data acquisition methods.
3:List of Experimental Equipment and Materials:
Enumerates the required instruments, devices, and materials, along with their specifications and intended uses.
4:Experimental Procedures and Operational Workflow:
Provides a step-by-step description of the experimental process, covering equipment setup, data collection techniques, and control of variables during the experiment.
5:Data Analysis Methods:
Explains the approach for analyzing experimental data, including statistical techniques and software tools utilized.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
CHI 608E electrochemical workstation
608E
CHI
Used for electrochemical measurements in the experiment.
-
UV-vis spectrometer
Cary 50
Varian-Agilent
Used for determining the MB concentration at the absorbance wavelength of 660 nm.
-
TOC-L TOC Analyzer
TOC-L
Shimadzu
Used for determining the total organic carbon concentration in the PEC decolorization system.
-
Scanning electron microscopy (SEM)
JSM700F
JEOL
Used for characterizing the deposited MnO2 precipitates.
-
high resolution transmission electron microscopy (HRTEM)
JEM-2100 HRTEM
JEOL
Used for characterizing the deposited MnO2 precipitates.
-
hematite electrode
Used as a photocatalyst in the photoelectrochemical system for wastewater treatment and hydrogen generation.
-
fluorine doped tin oxide (FTO) substrates
Used as a substrate for the hematite electrode.
-
platinum plate counter electrode
Used as a counter electrode in the photoelectrochemical system.
-
saturated calomel reference electrode (SCE)
Used as a reference electrode in the photoelectrochemical system.
-
simulated sunlight
AM 1.5 G
Used for illumination in the experiment.
-
MW600 standard portable dissolved oxygen meter
MW600
Milwaukee
Used for determining the dissolved oxygen concentration in the systems.
-
energy dispersive X-ray analysis (EDX)
Used for element characterization of the MnO2 precipitates.
-
X-ray photoelectron spectrometer (XPS)
Quantera SXM/Auger
PHI
Used for identifying the oxidation state of Mn species on hematite surface after illumination.
-
登录查看剩余11件设备及参数对照表
查看全部