修车大队一品楼qm论坛51一品茶楼论坛,栖凤楼品茶全国楼凤app软件 ,栖凤阁全国论坛入口,广州百花丛bhc论坛杭州百花坊妃子阁

Reactive Species Detection in Biology || UV–Vis Absorption and Chemiluminescence Techniques

DOI:10.1016/B978-0-12-420017-3.00006-2 出版年份:2017 更新时间:2025-09-04 15:30:14
摘要: Spectrophotometric techniques involving ultraviolet and colorimetric detection offer a convenient way of detecting reactive species (RS) formation due to the prevalence of UV-Vis spectrophotometer in research laboratories. Conventional spectrophotometric measurement of RS exploits their unique chemical reactivity with a small organic molecule and/or enzyme that has specificity to these RS where formation (or disappearance) of absorption peak/s at a particular wavelength is observed at the UV to the visible region of the electromagnetic spectrum. Direct detection of O2 from xanthine oxidase in the past involves rapid-freeze technique using electron paramagnetic resonance (EPR) spectroscopy. At the same time, spectrophotometric detection of O2 generated from xanthine oxidase/xanthine system was also employed for the investigation of the enzymatic property of superoxide dismutase (SOD) where the O2 levels were measured through reduction of ferricytochrome c, tetranitromethane, or oxidation of epinephrine to adenochrome. Several approaches have been developed since then to improve sensitivity with the use of submicromolar probe concentration thus allowing minimal interferences of the probe on the biological process being investigated. Specificity has also been improved to increase the reaction rate of probes to certain RS through synthesis of new and innovative analogues that exploit the unique chemistry between the probe and RS. Chromophore stability was also achieved through improved molecular design, optimized experimental conditions, or addition of supramolecular reagents since chromophores impart inherent thermodynamic stability as a function of its chemical structure, solvent polarity, pH, temperature, or due to presence of oxido-reductants or other reactive substances. Improved sample preparation and high-throughput analysis were also developed in order to maximize efficiency in the measurement markers of oxidative stress and determination of antioxidant capacity (AOC) of known molecules, food, biological fluid, or tissue. Therefore, spectrophotometric techniques for RS measurement have found broad application in the fields of biomedical research, clinical chemistry, plant biology, food chemistry, environmental chemistry, radiation chemistry, pharmaceuticals, toxicology, or material science to name a few, or just simply for the investigation of RS production in simple chemical systems. However, unlike the fluorescence probes, spectrophotometric as well as most applications of chemiluminescence probes do not provide spectrospatial image of the RS localization in cells, hence, one cannot deduce the site of radical production unless multiple probes and/or inhibitors are used with varying compartmentalization property (i.e., extracellular or intracellular). For example, in the investigation of radical production in cellular NADPH oxidase, several methods had been suggested such as measurement of O2 consumption, use of SOD-ferricytochrome c and horseradish peroxidase (HRP)/inhibitable probe such as Amplex Red for extracellular O2 and H2O2, respectively, and the HPLC analysis of the 2-OH-E marker for the quantification of intracellular O2.
作者:
AI智能分析
纠错
研究概述 实验方案 设备清单

Investigating the spectrophotometric and chemiluminescence techniques for detecting reactive species (RS) formation and their application in various fields such as biomedical research, clinical chemistry, and environmental chemistry.

An in-depth analysis and summary of the results summarized, emphasizing interpretability and forward-looking nature. Based on the results, it further refines the core findings, significance of the research, and suggestions for future studies.

The technical and application constraints of the experiments, as well as potential areas for optimization.

SCI高频之选
查看全部>
  • AQ6370D
    AQ6370D
    463

    型号:AQ6370D

    厂家:Yokogawa

    智能分析: Yokogawa AQ6370D是一款性能卓越的光谱分析仪,适用于光通信领域以及光放大器(EDFA)的测量和评估。其高波长分辨率、精准度和宽动态范围使其成为实验室和工业环境中的理想选择。虽然设备体积较大且预热时间较长,但其丰富的接口和出色的显示屏设计弥补了这些不足,整体是一款值得推荐的光谱分析仪。
    获取实验方案
  • ZEISS EVO Family

    型号:ZEISS EVO Family

    厂家:Carl Zeiss Microscopy GmbH

    智能分析: ZEISS EVO系列是一款高性能??榛璧缱酉晕⒕?,适用于材料科学、生命科学及工业质量控制等领域。其先进的技术特性包括高分辨率、广泛加速电压范围和集成EDS系统。该产品操作直观,支持多用户环境,适合科学研究和工业应用。然而,价格信息缺失以及潜在的维护成本可能是其需要注意的方面。总体而言,ZEISS EVO系列表现优秀,值得推荐给专业用户。
    获取实验方案
  • Crossbeam Family

    型号:Crossbeam Family350/550

    厂家:Carl Zeiss Microscopy GmbH

    智能分析: ZEISS Crossbeam系列是蔡司公司推出的一款高端光电分析设备,结合了场发射扫描电子显微镜(FE-SEM)和聚焦离子束(FIB)的功能,适用于材料科学、纳米技术和半导体行业等多个领域。其高分辨率成像能力和自动化样品制备功能使其成为高通量分析的理想选择。此外,该设备支持多种检测器,具备强大的多功能性,是高精度研究和工业应用的利器。然而,由于其高端定位,设备成本较高且操作需要专业技能。总体而言,该设备表现卓越,为科学研究和工业应用提供了先进的解决方案。
    获取实验方案
  • Axio Observer

    型号:Axio Observer

    厂家:Carl Zeiss Microscopy GmbH

    智能分析: Axio Observer是一款专为金相学研究设计的倒置显微镜系统,以其高效的设计和蔡司知名的光学技术为特色。它能够快速、灵活地分析大量样品,并支持自动化操作,适用于多种应用场景,包括晶粒尺寸分析、非金属夹杂物检测等。然而,其重量较大且光源寿命较短,可能对使用者提出了额外的维护和空间管理需求。总体而言,这款产品在性能和可靠性方面表现出色,特别适合专业实验室使用。
    获取实验方案
  • ZEISS LSM 990 Spectral Multiplex

    型号:ZEISS LSM 990 Spectral Multiplex

    厂家:Carl Zeiss Microscopy GmbH

    智能分析: ZEISS LSM 990 Spectral Multiplex是一款定位于高端科研机构的光谱成像系统,具有卓越的光谱分辨率和自动化功能,适用于复杂的生物、医学及材料科学实验。其高效的荧光标签分离能力和多功能自动化设计为用户提供了强大的实验支持。然而,高昂的价格和一定的学习曲线可能对中小型实验室构成挑战。总体而言,这是一款性能优越、适应性强的高端实验设备。
    获取实验方案
  • ZEISS Sigma 300 with RISE

    型号:ZEISS Sigma 300 with RISE

    厂家:Carl Zeiss Microscopy GmbH

    智能分析: ZEISS Sigma 300 with RISE是蔡司公司推出的一款高端光谱分析仪,集成了拉曼成像和扫描电子显微镜技术,能够提供高质量的化学和结构分析。其功能强大,支持多领域应用,但设备价格较高且操作学习曲线可能较陡。适用于科研机构和高端实验室,是材料科学和生命科学领域的理想选择。