研究目的
To clarify the relationship between the cell configurations within a solar cell panel and the power generation that occurs when an adjacent FPM is installed.
研究成果
The simulation model used in this study sufficiently reflects the experimental values. The power generation decreases as the number of series connections increases, but this decrease is nearly eliminated when a commercially available DC-DC converter is used. The difference in power generation between eight-cell series and parallel connections increases when multiple FPMs are installed due to the influence of shadows from adjacent FPMs.
研究不足
The study acknowledges the influence of shadows from adjacent FPMs and the accuracy problems of experimental apparatus.
1:Experimental Design and Method Selection:
The study uses simulations and experiments to examine the relationship between cell configurations and power generation in FPMs.
2:Sample Selection and Data Sources:
Mono-crystalline silicon solar cells were used for the solar cell panels in the FPM.
3:List of Experimental Equipment and Materials:
Solar cell panels, DC-DC converters, shunt resistors, and solar radiation meters were used.
4:Experimental Procedures and Operational Workflow:
Measurements were made on the rooftop of the Tokyo University of Science University Research Building.
5:Data Analysis Methods:
The power generation was calculated using simulation software and compared with experimental values.