研究目的
To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols based on clinical suspicion and adjusted image acquisition parameters.
研究成果
The implementation of new scan protocols based on clinical suspicion and adjusted acquisition parameters resulted in a significant reduction in radiation dose, with a 52.5% decrease in DLP per scan. This approach minimizes patient exposure while maintaining diagnostic efficiency, highlighting the importance of ongoing protocol review in radiology practice.
研究不足
The study utilized dose reports from the CT scanner without accounting for patient weight and body constitution, which affect effective dose estimation. Additionally, other dose reduction techniques like split-bolus contrast injection and iterative reconstruction algorithms were not used, and there was resistance from experienced radiologists to change established practices.
1:Experimental Design and Method Selection:
A retrospective and prospective observational study comparing radiation dose reports from abdominal CT scans before and after implementing new protocols based on clinical indications and adjusted technical parameters.
2:Sample Selection and Data Sources:
Included abdominal and pelvic CT scans of patients aged above 18 from a university hospital, with 511 studies in group A (before protocol changes) and 788 in group B (after changes), excluding scans with other body segments or technical errors.
3:List of Experimental Equipment and Materials:
Brilliance 64? 64-channel CT scanner (Philips Medical Systems), automatic dose modulation (Z-DOM?), intravenous iodinated contrast media, automatic bolus-tracking system (Bolus Tracking – ScanTools Pro?), and SPSS 20 program for statistical analysis.
4:Experimental Procedures and Operational Workflow:
Scans were performed using specified protocols (e.g., unenhanced, contrast-enhanced phases) with parameters adjusted for dose reduction. Data on CTDIvol and DLP were collected from scanner reports.
5:Data Analysis Methods:
Statistical analysis using Student t-test for independent variables to compare mean number of phases, CTDIvol per phase, DLP per phase, and DLP per scan between groups, with p < 0.05 considered significant.