研究目的
To develop a novel SPR sensor for the chiral recognition of L-tryptophan using a functionalized graphene oxide/molecular-imprinted polymer composite.
研究成果
The Gr/MIPSPR sensor demonstrated good selectivity, reusability, and higher chiral affinity for L-Trp over D-Trp, attributed to hydrogen bonding interactions. It shows promise for enantioselective adsorption of amino acids and other chiral compounds.
研究不足
The study may have limitations in terms of scalability, real-sample applicability, and potential interference from other compounds. Optimization of synthesis conditions and further validation in complex matrices could be areas for improvement.
1:Experimental Design and Method Selection:
The study involved designing an SPR sensor with a composite recognition element synthesized via one-pot in situ polymerization using polydopamine. Methods included FTIR, SEM, XRD, Raman spectroscopy, contact-angle measurements, and SPR kinetic analysis.
2:Sample Selection and Data Sources:
Samples included GO, L-Trp, D-Trp, dopamine hydrochloride, and other chemicals. Data were obtained from experimental measurements.
3:List of Experimental Equipment and Materials:
Equipment included Biacore3000 SPR system, XL30 TMP SEM, Vertex 70 FTIR spectrometer, JEM-2100F TEM, LabRam HR 800 Raman spectrometer, JC-2000C1 tensiometer, and Milli-Q water system. Materials included graphite, H2SO4, H2O2, L-Trp, D-Trp, dopamine hydrochloride, Tris, APS, b-mercaptoethylamine, and gold-coated SPR chips.
4:Experimental Procedures and Operational Workflow:
The SPR chip was cleaned and modified with a SAM. GO was reduced and polymerized with PDA and L-Trp in a one-pot process. The composite was immobilized on the chip, and SPR measurements were conducted at 25°C with PBST buffer. Data were analyzed using Biacore software.
5:Data Analysis Methods:
Data were analyzed using a one-to-one Langmuir binding model for kinetic parameters and DFT computations for interaction energies.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
XL30 TMP environmental scanning electron microscope
XL30 TMP
Philips-FEI
Used for SEM imaging to characterize the morphology of samples.
-
Vertex 70 spectrometer
Vertex 70
Bruker
Used for FTIR spectroscopy to analyze chemical compositions.
-
JEM-2100F transmission electron microscope
JEM-2100F
JEOL
Used for TEM imaging to study microstructures.
-
Biacore3000 SPR system
Biacore3000
Biacore
Used for SPR measurements to monitor ligand-receptor interactions in real-time.
-
LabRam HR 800
LabRam HR 800
Horiba
Used for Raman spectroscopy to analyze material properties.
-
JC-2000C1 tensiometer
JC-2000C1
Shanghai Zhongchen
Used for contact angle measurements to assess surface hydrophilicity.
-
Milli-Q system
Milli-Q
Millipore
Used for purifying water to resistivity of 18.2 MΩ cm for experiments.
-
gold-coated glass SPR sensor chips
Reichert Inc.
Used as the substrate for SPR measurements, with gold thickness of approximately 50 nm.
-
登录查看剩余6件设备及参数对照表