研究目的
To develop a method using electrochemical impedance spectroscopy (EIS) with metal oxide nanoparticle-modified carbon paste electrodes for determining photosensitizing dye No. 201 (Quaternium-73) in cosmetics.
研究成果
The SnO2 nanoparticle-modified carbon paste electrode is effective for determining Quaternium-73 in cosmetics, offering good sensitivity, linear range, stability, and lower cost compared to HPLC methods. The EIS-based approach is simple and rapid.
研究不足
The method may have limitations in terms of specificity and interference from other components in cosmetics. Optimization of metal oxide ratios and pH conditions is necessary for broader applicability.
1:Experimental Design and Method Selection:
The study employed electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) to evaluate and select electrodes for detecting Quaternium-
2:The rationale was to find a sensitive and cost-effective alternative to HPLC methods. Sample Selection and Data Sources:
Quaternium-73 was purchased from Hayashibara Company. Cosmetic samples (anti-acne cleansing gel and spray) were commercially obtained and prepared by dilution and centrifugation.
3:List of Experimental Equipment and Materials:
Equipment included a potentiostat/galvanostat (SP-150; Bio-Logic SAS), HPLC system (L-7100 pump, L-7455 detector; Hitachi), and various electrodes (carbon fiber, carbon paste, metal oxide-modified carbon paste). Materials included metal oxide nanoparticles (tin, cerium, cobalt, iron, nickel oxide; Sigma-Aldrich), graphite powder, paraffin oil, and buffers.
4:Experimental Procedures and Operational Workflow:
Electrodes were prepared by mixing graphite powder, paraffin oil, and metal oxides. EIS and DPV measurements were conducted in buffer solutions at specific pH and potentials. Cosmetic samples were extracted, filtered, and analyzed.
5:Data Analysis Methods:
Data were analyzed using EC-Lab software for EIS and DPV, with impedance spectra interpreted for electron transfer resistance. HPLC data were integrated for comparison.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
HPLC pump
L-7100
Hitachi
Part of the HPLC system for liquid chromatography analysis.
-
HPLC injector
7125
Hitachi
Used for sample injection in HPLC.
-
photodiode array detector
L-7455
Hitachi
UV detection in HPLC.
-
chromatogram data integrator
D-7000
Hitachi
Data analysis for HPLC.
-
potentiostat/galvanostat
SP-150
Bio-Logic SAS
Used for electrochemical measurements including EIS and DPV.
-
Ag/AgCl electrode
RE-1
Bioanalytical Systems
Reference electrode in electrochemical measurements.
-
C18 column
Phenomenex Luna
Scientific Hightek Co.
Used for reverse-phase HPLC separation.
-
metal oxide nanoparticles
Sigma-Aldrich
Modification of carbon paste electrodes for enhanced electrocatalytic properties.
-
登录查看剩余6件设备及参数对照表