研究目的
Investigating the relaxation dynamics of optical excitations in boron-doped diamond, specifically focusing on the lifetimes of excited boron states and the mechanisms of intracenter relaxation, to understand potential applications in optoelectronics.
研究成果
The study demonstrates ultrafast nonradiative intracenter relaxation in boron-doped diamond, with lifetimes in the picosecond range, dominated by cascade processes involving single- and multiple-phonon emissions. Isotopic enrichment and temperature had minimal impact on relaxation rates. These findings suggest that boron-doped diamond is unsuitable for population inversion-based lasing but is promising for fast optoelectronic devices like optical switches and detectors.
研究不足
The temporal resolution was limited to about 1 ps due to FEL micropulse duration, and the time window was up to 5 ns, potentially missing longer relaxation components. The theoretical models relied on simplifications, such as isotropic effective mass and deformation potential, which may not fully capture the complexity of electron-phonon interactions. Sample heterogeneity and impurity concentrations could affect results, and the study did not explore higher temperatures or different doping levels extensively.
1:Experimental Design and Method Selection:
The study employed a pump-probe technique using a wavelength-tunable infrared free electron laser (FEL) to investigate relaxation dynamics. The method involved resonant excitation of boron acceptor states and measurement of transmission changes with variable delays between pump and probe pulses. Theoretical models, including cascade relaxation with multiple levels, were used for data analysis.
2:Sample Selection and Data Sources:
Samples were IIb type boron-doped diamond single crystals grown by the high-pressure high-temperature (HPHT) method, with low nitrogen content. Two samples were used: one doped with natural boron (80% 11B + 20% 10B) and another with isotopically enriched 11B (99%). Samples were cut, polished, and wedged to avoid optical feedback.
3:List of Experimental Equipment and Materials:
Equipment included a Bruker VERTEX 80v infrared Fourier transform spectrometer (FTS) for absorption spectra, a free electron laser (FEL) at FELIX Laboratory for pump-probe measurements, a liquid helium flow cryostat for temperature control, a mercury cadmium telluride (MCT) infrared detector, beam splitters (BaF2), delay stages, power attenuators, polarization rotators, parabolic mirrors, and a boxcar integrator. Materials included boron-doped diamond samples with specified boron concentrations.
4:Experimental Procedures and Operational Workflow:
The FEL generated micropulses at 25 MHz repetition rate, split into pump, probe, and reference beams. Pump and probe beams were focused on the sample, with variable delays introduced via a delay stage. Transmission signals were measured at different temperatures (5 K to room temperature), pump wavelengths (3.4-4.1 μm), and intensities. Data were normalized and analyzed to extract relaxation times.
5:4-1 μm), and intensities. Data were normalized and analyzed to extract relaxation times. Data Analysis Methods:
5. Data Analysis Methods: Data were fitted using multi-level cascade relaxation models (two-, three-, and four-level) to derive time constants. The analysis involved solving balance equations for level populations and minimizing root mean square deviations. Radiative recombination rates were estimated based on absorption cross-sections, and nonradiative processes were emphasized.
独家科研数据包,助您复现前沿成果,加速创新突破
获取完整内容-
Bruker VERTEX 80v
VERTEX 80v
Bruker
Used for obtaining infrared absorption spectra of the diamond samples with high spectral resolution.
VERTEX 80 & 80v FT-IR Spectrometers
立即获取同款设备 -
Free Electron Laser
FELIX
FELIX Laboratory
Generated wavelength-tunable infrared pulses for pump-probe experiments, providing short pump pulses.
暂无现货
预约到货通知
-
Infrared Detector
MCT
Detected transmitted probe and reference beams in the pump-probe setup.
暂无现货
预约到货通知
-
Beam Splitter
BaF2
Split the FEL beam into pump, probe, and reference beams.
暂无现货
预约到货通知
-
Liquid Helium Flow Cryostat
Cooled the diamond samples to temperatures between 5 K and room temperature for experiments.
暂无现货
预约到货通知
-
Boxcar Integrator
Registered the differential transmission signal in the pump-probe measurements.
暂无现货
预约到货通知
-
DiamondView
DiamondViewTM
DTS
Used for photoluminescence mapping of the diamond samples to assess boron distribution.
暂无现货
预约到货通知
-
登录查看剩余5件设备及参数对照表
查看全部